6v12ah kanglida battery,VRLA sealed type battery, deep cycle lead acid battery
USD $7.5 - $9.5 /Piece
Min.Order:10 Pieces
Zhengzhou Kanglida Electronic Power Co., Ltd.
Maintenance free deep cycle storage battery building intercom
6v 1.3ah rechargeable storage deep cycle batteries security alarm system
Rechargeable lead acid battery building intercom/storage exide battery
Maintenance free lead acid deep cycle battery building intercom
Austria 12v2ah VRLA rechargeable battery manufacturer for building intercom
Maintenance free sealed lead acid battery 6v12ah
Application
Maintenance free storage battery 6v12ah is used for children’s toy car, electric cycle, solar garden light, power distribution equipment and so on.
Advantage
1. The battery is full of power when it’s out of factory, no need to use liquid charge;
2. no memory, no need to discharge battery use, suitable for circuit design;
3. by high partition, adsorption and strong;
4. there is no flowing liquid (poor liquid), does not leak acid and free Upside down,
5. comply with environmental requirements, ease of use,
6. the use of lead-calcium alloys, battery self-discharge is very low,
7. easy storage, less maintenance;
8. using ABS plastic shell and valve technology for safe use.
battery characteristic | ||||
Nominal voltage | 6V | |||
Nominal capacity(20h rate) | 12Ah | |||
Size | Total height | 100mm | ||
length | 150mm | |||
width | 50mm | |||
height | 100mm | |||
Weight | 1.85kg | |||
Rated capacity 25°C(77°F) | 20 hour rate(0.60A) | 12.0Ah | ||
10 hour rate(1.10A) | 11.0Ah | |||
5 hour rate(2.04A) | 10.2Ah | |||
1 hour rate(7.20A) | 7.20Ah | |||
Internal resistance | in full charge status 25°C(77°F) | 10mΩ | ||
Capacity at different temperature(10h) | 40°C(104°F) | 102% | ||
25°C(77°F) | 100% | |||
0°C(32°F) | 85% | |||
-15°C(5°F) | 65% | |||
Self discharge 25°C(77°F) | capacity after 3 months | 91% | ||
capacity after 6 months | 82% | |||
capacity after 12 months | 64% | |||
Mode of charge (constant voltage) 25°C(77°F) | cycle-use | initial charging current less than4.80A , voltage7.20-7.40V | ||
float-use | Initial charging current less than 1.80A voltage6.75-6.90V |
More details about 6v12ah battery
different batteries and applications
1. Could you do OEM?
Yes, we can OEM for you and submit the law of intellectual property rights.
2. Are you a factory?
Yes, our factory located in Huizhou city, Guangdong province, PRC. and we have 2 sales offices, one is in Zhenzhou city, Henan province, and the other one is in Shenzhen city, Guangdong province.
3. What is your product warranty?
the warranty is at least 1 year, free replace battery in the warranty, but, we supply service from start to end
4.Why use KANGLIDA battery?
4.1, 3-10years of service life to save your time, money;
4.2, Can be stored on open circuit without charging for up to 1years;
4.3, Can be mounted any side in any position except inverted;
4.4, no need to add water, drycell design with resealable venting system;
4.5, Improved safety, no acid spills, no escaping gases, clssified by National Center for Quality Supervison and Inspection of Battery Products.
5. How long did KANGLIDA manufacture lead acid battery?
we specialized manufacturing and developing lead acid battery 15years.
6. where KANLIGDA battery is using?
Kangalida batttery is widely used in backup power system such as UPS, fire alarm system, building intercom, elevator emergency evacuation system, emergency lights, electronic products, kids toy car, parking lock, flashing lights, traffic lights, DC panel, solar and wind power generation system ,etc. cann't be used in moto car/elcetric bike/vehicles/scooter.
Notice
1. Don’t near the hot source and don’t under the sunshine.
2. Don’t charge in the sealed container.
3. No short circuit. It should be addition charge if you don’t use, and single charge per three months, to avoid irreversible sulfating. The battery should be changed when the battery jar broken or the electrolyte omitted, to avoid acid corrosion.
4. Don’t store in the space of acid gas.
5. You should be careful and regular check when use the battery. To avoid the battery don’t work. You should change the battery if the capacity is not full or has been damage, especially after one year using.
6. Don’t put the battery in the fire, or it will explode.
7. Please use cotton cloth to clean, if the battery is broken down and leak electrolyte. Please wash your skin when touch the electrolyte.
8. Don’t clean the battery by using the organic solution. (e.g. petrol)
1. The battery is full of power when it’s out of factory, no need to use liquid charge;
2. No memory, no need to discharge battery use, suitable for circuit design;
3. By high partition, adsorption and strong;
4. There is no flowing liquid (poor liquid), does not leak acid and free Upside down;
5. Comply with environmental requirements, ease of use;
6. The use of lead-calcium alloys, battery self-discharge is very low;
7. Easy storage, less maintenance;
8. Using ABS plastic shell and valve technology for stable quality safe use.
9. Fresh lead board , long use life and low pollution
send your inquiry details in the below, chat or click "Send" now!
Tel: +86 15537106828
Skype:kldbattery
QQ: 3153542274