Industrial longlife 6v4ah building intercom battery, rechargeable SLA battery

Industrial longlife 6v4ah building intercom battery, rechargeable SLA battery

USD $4 - $5 /Piece

Min.Order:500 Pieces

Supply Ability:
1000 Piece / Pieces per Month
Port:
Shenzhen
Payment Terms:
Credit Card PayPal

Quick Details View All >

Place of Origin:
Henan, China
Brand Name:
KLD battery
Model Number:
CA640
Usage:
Other, electronic scale,vidicon,building talk-back
Voltage:
Other, 12v
Sealed Type:
Sealed

Zhengzhou Kanglida Electronic Power Co., Ltd.

Business Type: Manufacturer
Zhengzhou Henan China
Main Products: 4v gel battery ,6v gel battery ,12v gel battery ,gel UPS battery ,gel Solar battery

Product Details

Specifications

1.Low self-discharge and easy storage
2.Maintenance-free operation
3.15 years design time
4.Good service after-sale

Industrial longlife 6v4ah building intercom battery, rechargeable SLA battery

Zhengzhou Kanglida Electronic Power Co., Ltd

1.15 years manufacturing lead acid exide battery in China;

2.Recorded by China Public Security and China Security Yearbook;

3.Qualified Supplier recommended to national security enterprise ;

4.CE and UL Certificated.

 

Advantages

1.The battery is full of power when it’s out of factory, no need to use liquid charge;

2.no memory, no need to discharge battery use, suitable for circuit design;

3.by high partition, adsorption and strong;

4.there is no flowing liquid (poor liquid), does not leak acid and free Upside down;

ply with environmental requirements, ease of use;

6.the use of lead-calcium alloys, battery self-discharge is very low;

7.easy storage, less maintenance;

8.using ABS plastic shell and valve technology for stable quality safe use.

9.fresh lead board , long use life and low pollution

 

Date parameter

Industrial longlife 6v4ah building intercom battery, rechargeable SLA battery

 

battery characteristic

Nominal voltage

6V

Nominal capacity(20h rate)

4.0Ah

Size

Total height

106mm

length

97mm

width

47mm

height

100mm

Weight

0.62kg

Rated capacity                       25°C(77°F)

20 hour rate(0.20A)

4.00Ah

10 hour rate(0.37A)

3.70Ah

5 hour rate(0.68A)

3.40Ah

1 hour rate(2.40A)

2.40Ah

Internal resistance

in full charge status 25°C(77°F)

25mΩ

Capacity at different temperature(10h)

40°C(104°F)

102%

25°C(77°F)

100%

0°C(32°F)

85%

-15°C(5°F)

65%

Self discharge     25°C(77°F)

capacity after 3 months

91%

capacity after 6 months

82%

capacity after 12 months

64%

Mode of charge (constant voltage)       25°C(77°F)

cycle-use

initial charging current less than1.60A ,                    voltage7.05-7.20V

float-use

Initial charging current less than 0.60A voltage6.75-6.90V

 

 

 

Industrial longlife 6v4ah building intercom battery, rechargeable SLA battery

 Industrial longlife 6v4ah building intercom battery, rechargeable SLA battery

CE & UL Certificate

 

 Industrial longlife 6v4ah building intercom battery, rechargeable SLA batteryIndustrial longlife 6v4ah building intercom battery, rechargeable SLA battery

 

Production process diagram

Industrial longlife 6v4ah building intercom battery, rechargeable SLA battery

Other Specification

 

Type

Dimension(mm)

Plate No.

Weight(g)

6V1.3AH

97*24*51

"+"6 / "-"9

265

6V2AH

66*33*75

"+"6 / "-"9

350

6V2.3AH

44*40*90

"+"3 / "-"6

378

6V2.5AH

70*47*100

"+"3 / "-"6

460

6V2.8AH-A

66*33*96

"+"6 / "-"9

480

6V2.8AH

66*33*96

"+"6 / "-"9

540

6V3AH

125*34*60

"+"9 / "-"12

575

6V3.2AH

66*33*118

"+"6 / "-"9

615

6V4AH

70*47*100

"+"6 / "-"6

580

6V4AH

70*47*100

"+"6 / "-"9

670

6V4.2AH

70*47*100

"+"6 / "-"9

710

6V4.5AH

70*47*100

"+"6 / "-"9

740

6V4.8AH

70*47*100

"+"6 / "-"9

800

6V5.5AH

70*47*100

"+"9 / "-"9

830

6V6.5AH

132*46.5*78

"+"15 / "-"18

1140

6v 7AH

151*35*93

"+"9 / "-"12

1000

6V10AH

151*50*94

"+"15 / "-"18

1570

6V12AH

151*50*94

"+"15 / "-"18

1840

 

 

Notice

Don’t put battery close to the hot source and not under the sunshine.

Don’t charge in the sealed container.

No short circuit. It should be addition charge if you don’t use, and single charge per three months, to avoid irreversible sulfating. The battery should be changed when the battery jar broken or the electrolyte omitted, to avoid acid corrosion.

Don’t store in the space of acid gas.

You should be careful and regular check when use the battery. To avoid the battery don’t work. You should change the battery if the capacity is not full or has been damage, especially after one year using.

Don’t put the battery in the fire, or it will explode.

Please use cotton cloth to clean, if the battery is broken down and leak electrolyte. Please wash your skin when touch the electrolyte.

Don’t clean the battery by using the organic solution. (e.g. petrol)

 

 

Thanks for your attention, Any questions or requests,please do feel free to contact us.

Tel:18625500662                        Skype: kanglidabattery

Contact Supplier

Mr. TianLong He Manager Chat Now
Telephone
86-0371-68753149,13503863022
Mobile
13503863022
Fax
86-371-69381600
Address
Room No.418-423,4 Floor,B building,East of Lianyun road, North of Hanshan dong road,Erqi district, Zhengzhou, China. Zhengzhou,Henan

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Batteries > Storage Batteries
Categories
Hi~