AAC (All Aluminium Conductors) (Aluminium Standed Conductors) ASC cable
USD $0.0001 - $23.56 /Kilometer
Min.Order:1 Kilometer
AAC (All Aluminium Conductors) (Aluminium Standed Conductors) ASC cable
AAC cable (All Aluminum Conductors):
1). Standard:
IEC61089, BS215 part1, DIN48201 part5, ASTM B231, BS EN50182
2). Specification:
AAC cable is composed by bare concentric-lay-stranded aluminum wires with a straight round central aluminum wire surrounded by one or more layers of helically layed aluminum wires.
3). Application:
* AAC cable is used in overhead electric power transmission and distribution lines with various grade voltages.
* Under the same weight, AAC is with higher DC resistance and lower cost than Copper conductor.
* Aluminium is light and be easy to lay.
We can also manufacture AAC cable according to customers special requirements.
Technical Characteristics Based on Standard DIN 48201 / DIN EN50182 | |||||||
Code number | Area | Number of wires | Wire diameter | Conductor diameter | Linear mass | Rated strength | D.C. resistance at 20oC |
mm2 | No. | mm | mm | kg/km | kN | Ω/km | |
16 | 15.9 | 7 | 1.7 | 5.1 | 43.4 | 3.02 | 1.7986 |
25 | 24.2 | 7 | 2.1 | 6.3 | 66.3 | 4.36 | 1.1787 |
35 | 34.4 | 7 | 2.5 | 7.5 | 93.9 | 6.01 | 0.8317 |
50 | 49.5 | 7 | 3 | 9 | 135.2 | 8.41 | 0.5776 |
50 | 48.3 | 19 | 1.8 | 9 | 132.9 | 8.94 | 0.5944 |
70 | 65.8 | 19 | 2.1 | 10.5 | 180.9 | 11.85 | 0.4367 |
95 | 93.3 | 19 | 2.5 | 12.5 | 256.3 | 16.32 | 0.3081 |
120 | 117 | 19 | 2.8 | 14 | 321.5 | 19.89 | 0.2456 |
150 | 147.1 | 37 | 2.25 | 15.8 | 405.7 | 26.48 | 0.196 |
185 | 181.6 | 37 | 2.5 | 17.5 | 500.9 | 31.78 | 0.1588 |
240 | 242.5 | 61 | 2.25 | 20.3 | 671.1 | 43.66 | 0.1193 |
300 | 299.4 | 61 | 2.5 | 22.5 | 828.5 | 52.4 | 0.0966 |
Technical Characteristics Based on Standard BS 215-1 | |||||||
Code name | Nominal aluminium area | Stranding and wire diameter | Sectional area | Approx. overall diameter | Approx. mass | Calculated D.C. resistance at 20oC | Calculated breaking load |
mm2 | No./mm | mm2 | mm | kg/km | Ω/km | kN | |
MIDGE | 22 | 7/2.06 | 23.33 | 6.18 | 64 | 1.227 | 3.99 |
ANT | 50 | 7/3.10 | 52.83 | 9.3 | 145 | 0.5419 | 8.28 |
FLY | 60 | 7/3.40 | 63.55 | 10.2 | 174 | 0.4505 | 9.9 |
WASP | 100 | 7/4.39 | 106 | 13.17 | 290 | 0.2702 | 16 |
HORNET | 150 | 19/3.25 | 157.6 | 16.25 | 434 | 0.1825 | 25.7 |
CHAFER | 200 | 19/3.78 | 213.2 | 18.9 | 587 | 0.1349 | 32.4 |
COCKROACH | 250 | 19/4.22 | 265.7 | 21.1 | 731 | 0.1083 | 40.4 |
BUTTERFLY | 300 | 19/4.65 | 322.7 | 23.25 | 888 | 0.08916 | 48.75 |
Technical Characteristics Based on Standard ASTM B231 | ||||||||
Code Words | Size | Area | Number of wires | Wire diameter | Conductor diameter | Linear mass | Rated strength | Calculated D.C. resistance at 20oC |
AWG or kcmil | mm2 | No. | mm | mm | kg/km | kN | Ω/km | |
Oxlip | 4/0 | 107.2 | 7 | 4.42 | 13.26 | 295.2 | 17 | 0.268 |
Tulip | 336.4 | 170.5 | 19 | 3.38 | 16.9 | 469.5 | 27.3 | 0.1688 |
Cosmos | 477 | 241.7 | 19 | 4.02 | 20.1 | 664.8 | 37 | 0.1194 |
Orchid | 636 | 322.3 | 37 | 3.33 | 23.31 | 886.9 | 50.4 | 0.0895 |
Arbutus | 795 | 102.8 | 37 | 3.72 | 26.04 | 1109 | 61.8 | 0.0717 |