Duplex Triplex Service Drop ABC Cable Overhead Aluminum Conductor ABC Conductor
USD $0.01 - $50 /Meter
Min.Order:1000 Meters
Overhead XLPE/PE Insulation ABC Cable Service Drop ABC Cable
11kv abc cable Stranded aluminium conductor aerial bundled Cable
Duplex triplex quadruplex abc cable Aerial Bounded cable service drop cable
Twisted ABC Cable PVC Insulated ABC Overhead Transmission Line Power Cable Specification
Factory sale Overhead ABC Cable Aerial Bundled Conductor cable
Duplex Triplex ABC Cable Service Drop
Aerial Bunbled Cable (ABC cable) has characters of power-transmitting and strong mechanical. In comparison with bare wire, duplex aerial bundled cable (ABC cable) boasts many advantages, such as : small span in laying, higher safe reliability, better atmosphere aging resistance property. Duplex Aerial bundled cable has the priority to be used in urban and rural transmitting construction project.
Description
Since duplex ABC cable have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist..
Application
Primarily used for 120 volt overhead service applications such as street lighting,outdoor lighting,and temporary service for construction. To be used at voltage of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene(XLPE) insulated conductors.
Standard
ASTM B230, B231, B232 and B-399 ,B498,ICEA S-76-474 etc.
1. Duplex Service Drop
(1).Application
Duplex ABC Cable Primarily used for 120 volt overhead service applications such as street lighting,outdoor lighting,and temporary service for construction.To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75oC for polyethylene insulated conductors or 90oC for crosslinked polyethylene(XLP)insulated conductors.
(2).Construction
Code Word | Phase conductor | Bare Neutral Messenger | Nominal Lay Length | Weight Per 1000ft. (lbs.) | Allowable Ampacities+ | |||||||
Size (AWG) | Stranding | Insul. Thick. (Mils) | Size (AWG) | Stranding | Rated Strength (lbs.) | inches | XLP | POLY | XLP | POLY | ||
AAC Neutral-messenger | ||||||||||||
Pekingese | 6 | 1 | 45 | 6 | 7 | 563 | 10.36 | 61 | 61 | 85 | 70 | |
Collie | 6 | 7 | 45 | 6 | 7 | 563 | 10.36 | 64 | 64 | 85 | 70 | |
Dachshund | 4 | 1 | 45 | 4 | 7 | 881 | 10.36 | 92 | 92 | 115 | 90 | |
Spaniel | 4 | 7 | 45 | 4 | 7 | 881 | 10.36 | 96 | 96 | 115 | 90 | |
Doberman | 2 | 7 | 45 | 2 | 7 | 1350 | 14.88 | 147 | 147 | 150 | 120 | |
Malemute | 1/0 | 9 | 60 | 1/0 | 7 | 1990 | 14.88 | 234 | 234 | 205 | 160 | |
Code words for XLP insulated products are formed by adding/XLPto the conventional code words above(e.g.-Chihuahua/XLP)
+Conductor temperature of 90oC for XLP,75Oc for Poly;ambient temperature of 40oC;emissivity 0.9;2ft./sec. Wind in sun.