Water pump water level controllerHigh low liquid level control valveNew type intelligent high low liquid level controller
USD $23 - $35 /Set
Min.Order:10 Sets
Shenzhen Dianyingpu Technology Co., Ltd.
DYP-C352 high low liquid level controller could be combined with our non contact liquid level sensor of DYP-Y25 to use, which also could be combined with floater and other type of liquid level sensor to use, to achieve when the liquid level is too low in the container the liquid level sensor will send out the low level alarm signal and the water pump will automatic startup and add liquid; And when the liquid level achieves to a certain height the liquid level sensor will send out the signal to stop the water pump working automatically so that it achieves to the function of high low liquid level automatic control in container; This controller is with strong self-check protection function also is with water pump empty pumping and stop detection, high level overflow detection, pumping timeout detection; It is with diversification of control, you could control the water pump by manual mode also could be with automatic mode; It is with multiple output methods, one way of load output which controls the maximum power is 1600W, one way of alarm output which controls the max power is 800W, it is with relay normally open output also with AC110V or AC220V output; This controller is with complete functions and suitable for a variety of applications.
Features:
1) With strong compatibility, could use a variety of liquid level sensor input control;
2) With strong protective capability, with the function of preventing the pump idling and water overflow detection output, it is with 4 hours timeout water pumping alarm too;
3) Relay dry contact output, which is suitable in a variety of load control;
4) Diversification of control, you could control the water pump by manual mode also could by automatic mode;
5) Installs simple convenience, you could install it by screw or pathway of electric box;
Electrical parameter:
Name | Parameters |
Input voltage | AC100V-220V,50/60Hz |
Working voltage | DC12V |
Working current | Working current is less than or equal to 110mA; Static power consumption is less than or equal to 20mA; |
Load power | Under 1.6KW(overload or use in the three-phase water pump need to add the ac contactor) |
Alarm output | 800W normally open and close output (resistive load) |
Input signal | Low level induction signal input; High level induction signal input; Water pump idle running detection signal input; Water overflow alarm signal input; |
The voltage of sensor | DC12V |
Working temperature | -10℃~ +75℃ |
Dimension | 115*90*40 |
The corresponding diagram of signal input and relay output:
Input signal | Load output |
| Alarm signal status | Alarm output |
Low order is 0, High order is 0; | Normally open is closed; Normally closed is off; | Circulation | Low order is 0, High order is 1; | Normally open is closed; Normally closed is off; |
Low order is 1, High order is 0; | Normally open is closed; Normally closed is off; | High level overflow is 1; | Normally open is closed; Normally closed is off; | |
Low order is 1, High order is 1; | Normally open is off; Normally closed is closed; | Alarm status, load output are: Normally open is off; Normally closed is closed; (The relay is off state and the load disconnect and access to protection status) | ||
Low order is 1, High order is 0; | Normally open is off; Normally closed is closed; | |||
When the flooding water detection is 0; | Normally open is off; Normally closed is closed; (The relay is off state and the load disconnect and access to protection status) |
Typical application: