ZN63(VS1)-12 vd4 vacuum circuit breaker compact size VCB small pole distance VCB
USD $1,000 - $2,000 /Set
Min.Order:1 Set
ZN85-40.5 indoor high voltage vacuum switch 33kv vacuum switch 35kv high voltage breaker
ZN73A-12 permanent magnet type breaker indoor high voltage breaker 11kv VCB
ZN28(A)-12 Type Indoor High Voltage 12kv fixed type Vacuum Circuit Breaker
ZN23-40.5kV vacuum circuit breaker with drawable type breaker high voltage VCB
ZN12 (ZN72) -40.5 35kv Vacuum Circuit Breaker electrical medium voltage circuit breaker
ZN63 (VS1) -12 indoor high voltage vacuum circuit breaker is a three-phase AC 50Hz, rated voltage of 12kV indoor switchgear, control and protection for industrial and mining enterprises, power plants and substations, electrical facilities, and for frequent operation place. Adopting VET operating mechanism and circuit breaker integrated , design can be used as a fixed installation unit can also be equipped with special advance mechanism, the composition of handcart unit used. Some of the main circuit can use the whole solid seal post, in order to achieve smaller circuit breakers, high reliability, maintenance-free, can be equipped with KYN28A-12 (GZS) and other handcart switch cabinet in the home can also be used with fixed XGN switchgear.
The use of environmental conditions:
1.Ambient temperature: not higher than +40 °C, not less than -10°C (at -30 °C to allow storage and transportation).
2. Altitude: not exceed 1000m.
3. Relative humidity: daily average of not more than 95%,saturated vapor pressure daily average of not more than 2.2 × 10-3MPa, month average not more than 1.8 × 10-3MPa.
4. Earthquake intensity: not more than eight.
5. No fire, explosion hazard, serious filthy, chemical corrosion, as well as places of intense vibration.
Mainly technical parameters
NO | Item | Units | parameters | |||
1 | Rated voltage | KV | 12 | |||
2 | Rated insulation level | Rated Lightning Impulse voltage tolerance | KV | 75 | ||
1min Frequency voltage | 42 | |||||
3 | Rated short-circuit breaking current | KA | 20/25 | 31.5 | 40 | |
4 | Rated current | A | 630 1250 | 630 1250 1600 2000 2500 3150 | 1250 1600 2000 2500 3150 4000 | |
5 | Rated thermal stability of current (RMS) | KA | 20/25 | 31.5 | 40 | |
6 | Dynamic Stability rated current (peak | 63 | 80 | 100 | ||
7 | Rated short-circuit closing current (peak) | 63 | 80 | 100 | ||
8 | Rated short-circuit breaking current breaking number | times | 50 | |||
9 | Frequency tolerance of the secondary circuit voltage (1min) | V | 2000 | |||
10 | Rated operating sequence |
| 0-0.3s-CO-180s-CO | |||
0-180s-CO-180s-CO(40kA) | ||||||
11 | Rated thermal stabilization time | S | 4 | |||
12 | Rated a single / back-to-back electric current breaking device group |
| 630/400 800/400(40KA) | |||
13 | Mechanical life | Times | 10000 |