Extruded XLPE insulation electric cable with rated voltage from 0.6/1KV to 8.7/15KV
Extruded XLPE insulation electric cable with rated voltage from 0.6/1KV to 8.7/15KV
Extruded XLPE insulation electric cable with rated voltage from 0.6/1KV to 8.7/15KV

Extruded XLPE insulation electric cable with rated voltage from 0.6/1KV to 8.7/15KV

USD $1 - $10 /Meter

Min.Order:1000 Meters

Supply Ability:
1000 Kilometer / Kilometers per Month
Port:
tianjin/qingdao
Payment Terms:
T/T

Quick Details View All >

Brand Name:
Beihou
Model Number:
YJV/ YJLV
Insulation Material:
XLPE
Type:
Medium Voltage
Application:
Underground
Conductor Material:
Copper

Zhengzhou Yuanda Cable Co., Ltd.

Business Type: Manufacturer,Trading Company
Zhengzhou Henan China
Main Products: Cable and Wire ,ABC Cable ,AAC\ ACSR ,PVC Cable

Product Details

Sketches of product construction

 

Extruded XLPE insulation electric cable with rated voltage from 0.6/1KV to 8.7/15KV

 

1,Conductor                  4,Insulation screen      7,Separator(Inner Cover)
2
,Conductor Screen     5,Metallic Screen         8,Armour
3
,XLPE Insulation        6,Filler                          9,Outer Sheath

 


Manufacturing standards


ASTM ICEA BS DIN IEC GB AS/NZS etc.
Operating features
Operating temperature
Max. Permissible continuous operating temperature of Conductors shall not exceed 90

Conductor Short circuit temperature
Not exceeding 250
 . (Max. Duration 5 seconds)
Bending radius:
Bending radius of single core cable:20D
Bending radius of multi-core cable: 15D
D=Actual overall diameter of cable (mm)
Installation temperature:
The lowest temperature of installation is 0 
.
Laying conditions and basic parameters for calculating current ratings:
Method of laying             Ambient temperature
In air                            40

Direct burial                          25

Soil thermal resistivity 1.0
· m/W
Layout of single core cables: In parallel
(Spacing side by side: 1D D=overall diameter)


Scope of cables Table

 

 

Type

No . of 
cores

Rated voltage(KV)

0.6/1

1.8/3

3.6/6

6/6   6/10

8.7/10  
 8.7/15

Nominal area of conductor (mm2)

YJV
YJLV



YJV22
YJLV22



YJV32
YJLV32

1,2,3,
3+1, 3+2,
4+1, 5

1.5-630

10-400

25-400

25-400

25-400

 


 

 

XLPE Insulated Power Cable

Type, description and main applications Table 2

 

 

Type

Description

Main application

YJV
YJLV

Cu or AL conductor
 XLPE insulated PVC 
Sheath  Power cable 

For laying indoor and outdoor, 
unable to bear certain external 
mechanical force but the tractive 
force during laying. Laying Single 
core cable in magnetic duct is 
not permissible 

YJV22 YJLV22

Cu or AL conductor 
XLPE insulated steel 
tape armoured PVC
sheathed power cable 

For laying underground, 
bear external mechanical force, 
but unable to bear large pulling force 

YJV32 YJLV32

Cu or AL conductor 
XLPE insulated thin steel 
wire armoured PVC sheathed 
power cable 

For laying under ground, 
vertical well, or underwater, 
able to bear certain pulling force. 

 

 

Extruded XLPE insulation electric cable with rated voltage from 0.6/1KV to 8.7/15KVExtruded XLPE insulation electric cable with rated voltage from 0.6/1KV to 8.7/15KV

Contact Supplier

Ms. Becky Zhou Chat Now
Telephone
0086-371-55699718
Mobile
15565062226
Address
No. 2304, Floor 23, Bldg. 1, No. 157, Fuyuan Road, Jinshui Dist. Zhengzhou,Henan

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Wires, Cables & Cable Assemblies > Electric Cable
Categories
Hi~