Application:
Used for overhead power transmission and distribution lines of AC rated voltage up to and including 1kV or rated voltage 10kV.
Type | Description |
JKLV | Aluminum conductor PVC insulated overhead cable with rated voltage 1KV. |
JKLHV | Aluminum alloy conductor PVC insulated overhead cable with rated voltage 1KV. |
JKLY | Aluminum conductor PE insulated overhead cable with rated voltage 1KV. |
JKLHY | Aluminum alloy conductor PE insulated overhead cable with rated voltage 1KV. |
JKLGY | ACSR conductor PE insulated overhead cable with rated voltage 1KV. |
JKLYJ | Aluminum conductor XLPE insulated overhead cable with rated voltage 1KV. |
JKLHYJ | Aluminum alloy conductor XLPE insulated overhead cable with rated voltage 1KV. |
JKLGYJ | ACSR conductor XLPE insulated overhead cable with rated voltage 1KV. |
Properties:
Special features which we can offer for LV and MV cables:
* Watertight construction (both radial and longitudinal).
* Available in long delivery lengths to reduce number of joints.
* Aluminum conductor up to 240mm².
* Different options for insulation (XLPE,LDPE, MDPE & HDPE).
* Weather resistant insulation and sheath material.
Standards
Rated voltages up to and including 1KV aerial insulated cable implement the standard GB/T 12527, AS/NZS 3560-1, BS 7870-5, VDE 0276-626-Al, ANSI/ICEA S-76-474 . Rated voltage 10KV aerial insulated cable implement the standard GB/T 14049.
Application Properties
Rated voltage is up to and including 1KV, 10KV.
The conductor long-term maximum working temperature:PVC and PE insulation should not exceed 70 °C,XLPE insulation should not exceed 90°C.
During short circuit (maximum permanent time is not more than 5 seconds), the maximum temperature of cable conductor : XLPE insulation 250°C, High-density polyethylene insulation 150°C;
When laying the cable, minimum ambient temperature of laying should not be lower than -20°C.
The minimum bending radius:≥20 (D+d)±5%mm, D is the cable overall diameter, d is the conductor diameter.
Rated voltage
Rate Voltage(kv): 0.6/1kV 10kV 25kV 35kV
No. of core and sectional area(mm2) :
1 Core 10-400 2 Core 10-185
3 Core 10-185 4 Core 10-150
(1+k) Core 10-185 (2+k) Core 10-185
(3+k) Core 10-185 (1+k+16) Core 10-185
(2+k+16) Core 10-185 (3+k+16) Core 10-185
K is the NO. of neutral core or load bearing line core. According to engineering requirements, to select one to go with the main core.
(A) represents steel stranded neutral core.
(B) represents aluminium alloy stranded neutral core.
16mm2 for public lighting line
1).Wrapped in rolls/coils/rings with Plastic film for small diameter cables such as building wires.
2).Treated wooden/steel-wooden drums for big diameter cables.
3).Cables are normally supplied in lengths of 100 meters,500 meters and 1000 meters according to cable size.Other length could be supplied if required.
Packaging:
In rolls, wooden drums, steel drums or iron drums.
Shipping:
1.Sample will be mailed by DHL, UPS, FEDEX, TNT, EMS etc for your selection (Freight Charge normally will be on buyer’s account).
2. Large quantity will ship by sea.
1.20 years professional cable manufacture experience since 1996.
2. Competitive price and standard quality.
3.Standardized quality management under ISO9001:2008
4.OEM (Original Equipment Manufacture)acceptable
5.Free sample are available.
6.24 hours online service,quickly response to your questions.