66kv outdoor termination knit for XLPE power cable
USD $1,500 - $5,000 /Set
Min.Order:1 Set
Qingdao Asun Machinery Co., Ltd.
66kv outdoor termination knit for XLPE power cable
1.Material: liquid silicone rubber
2.Easy installation
3.Good performance of flashover
4.excellent waterproof and sealing
Specification
Type | Product | Voltage | Cross section(mm2) |
QXNLG4 | crosslinked power cables dry insulating outdoor termination | 48/66KV | 185~1600mm2 |
QXNLG4 | crosslinked power cables dry insulating outdoor termination | 64/110KV | 240~1600mm2 |
Introduction
The high-voltage power cable accessories made of imported liquid silicone rubber has excellent heat resistance and cold resistance that can work safely under the temperature from -60 to 250 °C.
The series of the accessories such as dry insulating outdoor termination, porcelain bushing outdoor termination, compound bushing outdoor termination, dry GIS insulating termination, insulating joint, straight joint has passed the test of Wuhan electric power industry electrical equipment testing center and approved the acceptance of new products and technologies appraisement.
Main characteristic
Item | Technical data | |
66 KV accessories | 110 KV accessories | |
Rated voltage kV | 48/66 | 64/110 |
Max. operating voltage kV | 72.5 | 126 |
Power frequency voltage withstand test | 120kV/30min No breakdown No flashover | 160kV/30min No breakdown No flashover |
Room temperature partial discharge test | Test voltage 72kV,Partial discharge < 5pC | Test voltage 96kV,Partial discharge < 5pC |
Thermal cycle test | 96 KV heating for 8 hours, cooling for 16 hours, Conductor`s temperature is 95~100 °C(20 cycles) | 128 KV heating for 8 hours, cooling for 16 hours, Conductor`s temperature is 95~100 °C(20 cycles) |
Under the high temperature partial discharge test | 72 KV,95~100 °C, Partial discharge < 5pC | 96 KV,95~100 °C, Partial discharge < 5pC |
Lightning impulse voltage test | 450 KV positive and negative polarities each 10 times No breakdown No flashover | 550 KV positive and negative polarities each 10 times No breakdown No flashover |
After test of impulse voltage withstand voltage test | 120 KV/15min No breakdown No flashover | 160 KV/15min No breakdown No flashover |
Outdoor termination short-term power frequency voltage test | Rain status 120kV,1min No flashover No breakdown | Rain status 185kV,1min No flashover No breakdown |
Outdoor termination radio interference test | 61kV generated 1MHz interference voltage is not greater than 450μV | 81kV generated 1MHz interference voltage is not greater than 450μV |
Pressure leak test | no gas escaping at 0.2 Mpa 1 hours | no gas escaping at 0.2 Mpa 1 hours |
ASUNT group