Hot!!! low frequency single phase pure copper transformer pure sine wave ac dc inverter
USD $150 - $430 /Piece
Min.Order:1 Piece
Shenzhen Must Solar Power Co., Ltd.
low frequency single phase pure sine wave inverter power inverter dc 12v ac 220v
EP3000 series low frequency single phase pure sine wave DC/AC power star inverter
low frequency single phase pure sine wave DC/AC power inverter
3kw solar inverter 3000va solar power inverters+3000 Watt Pure sine wave inverter
<MUST Solar>Large charging current inverter,solar inverter,5kw inverter
Pure sine wave inverter name:
Hot!!! low frequency single phase pure copper transformer pure sine wave ac dc inverter
EP3000 INVERTER APPLICATION
Main Features:
1.1kw-6kw power range,12v/24v/48vdc optional, use pure copper transformer to increase efficiency;
2.165v-260v wide input voltage range ,40-70HZ input frequency;
3. low frequency and pure sine wave which can run inductive loads . main use for home and office: computer, lights, fan,tv, fridge,air-condition .etc;
4.built in 4 steps supper battery charger 30-75A to save charge time.Charger (bulk, absorption, float);
5.with 200cm battery cable;
6.Support generator 1hp/2hp/3hp;
7.Support solar system;
8.Remote control / RS232 , monitor inverter working by computer;
9.CE/ SONCAP certificate;
10.Charge current is adjustable 25%,50%,75%.100%;
11.Hybird solar system , Solar advantage, battery advantage.
NEW Function
1.Solar Priotity Inverter!
Inverter Charging current Ajustable 25% 30% 75% 100%
2.Solar Hybird Inverter!
Solar Energy , City power , DC to AC can transfer automatically;
When battery voltage is low (3 options---10v/10.5v/11v) , it will turn to city power automatically.
Detail as below:
1. Specifications solar power inverter:
EP3000 Series Inverter 1KW-6KW Specification | |||||||
MODEL | EP1012/1024 | EP1512/1524 | EP2012/2024 | EP3012/3024/3048 | EP4024/4048 | EP5024/5048 | EP6024/6048 |
Rated Output Power (W) | 1000 | 1500 | 2000 | 3000 | 4000 | 5000 | 6000 |
LINE MODE SPECIFICATIONS | |||||||
Input Voltage | 230Vac(120VAC selectable) | ||||||
Input Frequency | 50Hz/60Hz (Auto detection) | ||||||
Output Voltage Waveform | Pure sine wave | ||||||
Over-Load Protection(SMPSload) | Circuit breaker | ||||||
Output Short Circuit Protection | Circuit breaker | ||||||
Efficiency (Line Mode) | >95% | ||||||
Auto Transfer Relay | 30A | 40A | |||||
Transfer Time | 10ms (typical) | ||||||
Pass through without Battery | Yes | ||||||
Max Bypass Overload Current | 30A | ||||||
INVERT MODE SPECIFICATIONS | |||||||
Output Voltage Waveform | Pure sine wave | ||||||
Power Factor | 1 | ||||||
Output Voltage (V) | 230Vac/120 ±10% | 230Vac±10% | |||||
Output Frequency (Hz) | 50/60Hz ± 0.3Hz | ||||||
Auto Tracking Main Frequency (Hz) | 50Hz @ 48-54Hz; 60Hz @ 58-64Hz | ||||||
Output Voltage Regulation | ± 10% rms | ||||||
Efficiency | > 80% | ||||||
Over-Load Protection(SMPSload) | (110%<load<125%) ± 10%: Fault (shutdown output) after 15 minutes; (125%<load<150%) ±10%: Fault (shutdown output) after 60s; Load>150% ±10%; Fault (shutdown output) after 20s | ||||||
Surge Rating | 3000VA | 4500VA | 6000VA | 9000VA | 12000VA | 15000VA | 18000 VA |
Capable Of Starting Electric Motor | 1 HP | 2 HP | 3 HP | ||||
Inverter Breaker Size | 10A | 30A | 40A | ||||
DC Input Voltage | 12V/24V | 12V/24V | 12V/24V | 12V/24V/48V | 24V/48V | 24V/48V | 24V/48V |
Min DC Start Voltage | 11V/22V/43V | ||||||
Low Battery Alarm | 10.5Vdc ± 0.3Vdc for 12V battery; 21.0Vdc ± 0.6Vdc for 24V battery; 42.0Vdc ± 0.6Vdc for 48V battery | ||||||
Low DC input Shut-down | 10.0Vdc ± 0.3Vdc for 12V battery; 20.0vdc± 0.6Vdc for 24V battery; 40.0Vdc± 0.6Vdc for 48V battery | ||||||
High DC input Alarm & Fault | 16Vdc ± 0.3Vdc for 12V battery; 32Vdc ± 0.6Vdc for 24V battery; 64Vdc ± 0.6Vdc for 48V battery | ||||||
High DC input Recovery | 15.5Vdc ± 0.3Vdc for 12V battery; 31.0Vdc ± 0.6Vdc for 24V battery; 62.0Vdc ± 0.6Vdc for 48V battery | ||||||
Power saver | Load ≤25W | ||||||
CHARGE MODE SPECIFICATIONS | |||||||
Input Voltage | 230Vac / 1200Vac | ||||||
Input Voltage Range | 155-265Vac / 96-127Vac | ||||||
Output Voltage | Same as input voltage | ||||||
Multi Stage Smart Charger (Amp) | 35A/20A | 65A | 65A/40A | 65A/45A/25A | 65A/35A | 65A/40A | 65A/50A |
Charge Current Adjustable Gear | 25%, 50%, 75%, 100% | ||||||
Charger Short Circuit Protection | Circuit breaker | ||||||
Over Charge Protection | Bat. V ≥ 15.7Vdc/31.4Vdc/62.8Vdc, beeps 0.5s every 1s & fault after 60s | ||||||
GENERAL SPECIFICATIONS | |||||||
Safety Certification | CE, Soncap, ISO9001 | ||||||
Operating Temperature Range | 0°C to 40°C | ||||||
Storage temperature | 15°C below zero to 60°C | ||||||
Operation humidity | 5% to 95% | ||||||
Audible Noise | 60dB max | ||||||
Cooling | Forced air, variable speed fan | ||||||
Net Weight (KG) | 16 | 21 | 24 | 35 | 44 | 45 | |
Gross Weight (KG) | 19 | 24 | 28 | 39.2 | 48 | 49 | |
Inverter Size | 1000W/1500W/2000W/3000W: 423X185X160MM 4000W/5000W/6000W: 600X185X155MM | ||||||
Carton Box Size | 1000W/1500W/2000W/3000W: 570*315*300MM 4000W/5000W/6000W: 755*319*288MM | ||||||
Wooden Case Size | 1000W/1500W/2000W/3000W: 614X362X359MM 4000W/5000W/6000W: 799X362X359MM |
2. PICTURES of DC/AC inverter:
Pure Copper Transformer
3. PRODUCT CERTIFICATES
4. FACTORY PRODUCTION LINE TRAVEL
5. POWER INVERTER PACKING
6. HONGKONG ELETRONIC FAIR IN 2013!!!
2013
** Welcome your Sample Order to test quality first **
** For More Information, Please Inquiry NOW ^_^ **
Note: For more information, pls contact: Julie Hu, Skype: mustsolar-julie, 24 hours online.