ITC VA-6000MS

Digital Professional electronical Voice alarm switching

 

Our Fire Alarm Systems for PA and evacuation systems in accordance with EN 54-16 combine unique functionality in perfection with extremely simple programming and operation.
The optimum customer penefit results from state-of-the-art technologies and many years of experience, put into practice consistently.

 

 

Product Description

 VA-6000MS changeover is an integrated controller supporting main and backup amp swithing, speaker circuit grounding detection, open circuit and short circuit detection; compatible with three or four wire volume controller wiring, without extra wiring or power supply; combining 8 programmable stem node or wet node trigger inputs and 8 programmable on-line output signal. It works with class D amplifiers, traditional amplifiers to provid a safe, affordable solution to the PA & Voice Alarm system.

 

Features

*2U chassis design, high integrated, modularization;

*support speaker circuit grounding, open circuit and short circuit detection;

 

*support 3/4 wire horn circuit wiring;

 

*8 programmable trigger input interfaces;

 

*8 programmable trigger output interfaces;

 

*support power-saving mode when the amplifier has not input signal enters

 

*support lines redundance wiring;

 

*support linkage to fire alarm controller

 

Funtion:

 

*main amplifier automatic backup switching power amplifier, real-time detection, indicate by different color LEDs;

*real time monitoring speaker bus loop, power amplifier status, automatic control switch;

*allows amplifier enter into power saving mode when no signal input to save energy (start through VA-6000ST, default disabled);

*allows to configure the priority of network and local audio;

*support power through, even if the main and standby power supply is cut off at the same time (amplifier power supply normal), the local 8 audio signals are not affected;

 

*8 stem node or wet node input port, to trigger the pre-pragrammed language information to the specified zones or open the coresposing external power to the corresponding event warning;

*8 programmable relay signal output port, ouupt no voltage output short circuit relay control signal to the third party equipment to realize on-line automatic control;

*provide DC 24V standby power input interface ( connect to 24V DC supplied by VA-6000BC);

 

Specification

 

AC power supply

Voltage              

~ 230V,50/60Hz

maximum current         

0.3 A(not including the 4 wire strong cut output)

Specification of the fuse       

250V/1A,slow speed type

DC power supply

Voltage           

24V DC, ±20%

       maximum current           

2 A((not including the 4 wire strong cut output)

Power               

48W

performance index

Parallel signal input / output

 

Distortion               

<1%(rated output power),1kHz

frequency               

80Hz~20kHz

sensitivity            

385mV

Impedance              

10kΩ

SNR            

>70dB

Contact output

8 relay programmable output   

short circuit, no voltage

8 programmable trigger input 

level model:          

The highest 3.3V

Short circuit mode:               

no voltage, short circuit

Cooling way           

air cooled

Protection                      

delay / temperature / short / overload

Mechanical index

The size (length x width x depth)

484×88×447 mm(19 inches wide, 2U)

The net weight               

about 7.8 kg

Installation                 

desktop or 19 inch cabinet

color              

black

Environmental requirements

Environmental requirements

             

+5°C ~ +40°C

Storage temperature           

-20°C ~ +70°C

relative temperature            

<95%(no treatment)

 

Detailed Images

 

Digital Professional electronical Voice alarm switching

Digital Professional electronical Voice alarm switching

Digital Professional electronical Voice alarm switching

 

Company Information

Digital Professional electronical Voice alarm switchingDigital Professional electronical Voice alarm switchingDigital Professional electronical Voice alarm switchingDigital Professional electronical Voice alarm switchingDigital Professional electronical Voice alarm switching 

 

 

Contact Supplier

Ms. Fancy Fong Marketing Manager Chat Now
Telephone
86-20-84590536
Mobile
13560282091
Fax
86-20-34500530
Address
Building NO. A13-1, Yiku Industrial Park, The Hills, Dongyi Road, Panyu Guangzhou,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Security & Protection > Alarm
Categories
Hi~