ACSR conductor 25mm2
ACSR conductor 25mm2
ACSR conductor 25mm2
ACSR conductor 25mm2
ACSR conductor 25mm2
ACSR conductor 25mm2

ACSR conductor 25mm2

USD $0.2 - $3.6 /Meter

Min.Order:100 Meters

Supply Ability:
50000 Kilometer / Kilometers per Month
Port:
Qingdao
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal

Quick Details View All >

Place of Origin:
Henan, China
Brand Name:
Sanhe
Model Number:
acsr
Insulation Material:
Other, Non
Type:
High Voltage
Application:
Overhead

Zhengzhou Sanhe Cable Co., Ltd.

Business Type: Trading Company
Zhengzhou Henan China
Main Products: Concentric Cable ,ABC Cable ,ACSR & AAC ,Electric Wire ,Control Cable

Product Details

SCA Conductor/ ACSR conductor

 

Specifications

SCA/ACSR conductor offers optimal strangth for lin designing. Variable steel core stranding for desired strength to be achieved.

ACSR (Aluminum Conductor Steel Reinforced)

APPLICATIONS:

Used as bare overhead transmission cable and as primary and secondary distribution Cable. ACSR offers optimal strangth for lin designing. Variable steel core stranding for desired strength to be achieved without sacrificing ampacity.

 

CONSTRUCTION:

Aluminum 1350-H19 wires, concentrically stranded around a steel core. Core wire for ACSR is available with class A, B or C galvanizing ;Aluminum coated( AZ) or aluminum-clad steel core (AL). Aditional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease.

 

ACSR & AAC Conductor Wire (Aluminum Conduct Steel Reinforced)   is widely used in the overhead power distribution system of our country. 

We can supply this conductor according to different recognized standards, such as IEC61089, BS215, ASTM B232, CSA C49, DIN48204, JIS C3110, customer special specification also can be satisfied. 
All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM (AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228 
(AAAC) Conductor as per ASTM-B-399-1992 
(AAAC) Conductor as per BS-3242-1970 
(AAAC) Conductor IS: 398-IV-1994 
(ACSR) as per ASTM-B-233-1992 
(AAC) as per BS-215-1-1970 
(AAC) as per IS-398-1: 1976 
(AAC) as per ASTM-B-231-1990 
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992 
(ACSR) BS-215-II-1970 
(AACSR) as per IEC-1089-1191 
AAC(All aluminum conductor) are suited for overhead power line. 
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied. 
ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power 
Applications 
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity. 

 

Construction 
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease. 

 

Specifications 
ACSR bare conductor meets or exceeds the following ASTM specifications: 

B-230 Aluminum Wire, 1350-H19 for Electrical Purposes 
B-231 Aluminum Conductors, Concentric-Lay-Stranded 
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR) 
B-341 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ) 
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ) 
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR) 

Notes 
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions. 
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.

 BS-215-2-70 ACSR 
Code naneNominal AreaStranding &Wire DiameterApproximate overall diameterSection AreaApproximate weight
AluminumSteelAluminumSteelTotal
mm²No.mmNo.mmmmmm²mm²mm²Kg/km
Rabbit5063.3513.3510.0552.98.861.7214.1
Dog10064.7271.5714.1510513.6118.5394.7
Gopher2562.3602.367.0826.2026.272.1
Weasel3062.5912.597.7731.65.336.9128
Ferret406313942.47.149.5171.7
Horse70122.7972.7913.9573.442.8116.2538.1
Wolf150302.5972.5918.13158.136.9194.9725.9
Dingo150183.3513.3516.75158.78.8167.5507.4
Lynx175302.7972.7919.53183.442.8226.2842.4
Caracal175183.6113.6118.05184.210.2194.5589.2

 

ACSR conductor 25mm2

Our advantages:

 

ACSR conductor 25mm2

 

Friends, if any interest, pls feel free to contact us.

Your most sincere friend Coco is always here waiting for you. 

ACSR conductor 25mm2

Contact Supplier

Mr. James Yuan Manager Chat Now
Telephone
86-371-69176007
Fax
86-371-69176006
Address
The cross of Dong Er street and CBD out circle Henan

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Wires, Cables & Cable Assemblies > Electric Cable
Categories
Hi~