AAAC Totara from BS 50182/bare conductor/ overhead cable/Chinese manufacturer
USD $0.15 - $1.8 /Meter
Min.Order:1000 Meters
Zhengzhou Sanhe Cable Co., Ltd.
AAAC Yew conductor/ alloy cable /alloy conductor /HD AA cable/HD AA conductor
AAAC Upas conductor/ concentric lay cable/ bare conductor/ aluminum conductor
AAAC Sycamore /High conductivity aluminum / 8000 series/6000 series
AAAC Poplar / aluminum conductor/ air conductor/overhead cable
AAAC Elm /High conductivity aluminum cable/ Chinese factory/chinese manufacturer
AAAC Ash conductor/High conductivity aluminum series/6000 series cable/ 8000 series aluminum
AAAC Totara from BS 50182/bare conductor/ overhead cable/Chinese manufacturer
a.High tensile strength
b.Long life
c.Light in weight
d.Suitable for high as well as extra high overhead voltage lines
B,Standard: ASTM B232 ,IEC61089, BS215 part2, DIN48204, BS EN50182, GB/T 1179-2008
C,Brief Description:
AAAConductor may be manufactured for having a wide range of tensile strength as per requirement.
The principal advantage of these conductors are high tensile strength and light weight with longer spans as well as
with lesser supports. Due to the greater diameter of ACS Conductor a much higher corona limit can be obtained causing
big advantages on high as well as extra high voltage overhead lines.
D,Applications:
Used as bare overhead transmission cable and as primary and secondary distribution cable.
AAAC Conductor offers optimal strength for line design. Variable steel core stranding enables
desired strength to be achieved without sacrificing ampacity.,AAAC Conductor are used extensively
for overhead ground wires, river crossings etc. These AAAC Conductor are available with us in various types for
meeting the exact requirements of the clients.
E,Package:In coils, wooden drums, steel drums or steel-wooden drums.
We could producing according to the customers' requirements.Welcome your request for any quotations!
Code Words |
AWG |
Stranding |
Mass |
Rated Strength | DC Resistance at 20 ℃ | |
|
| No. | mm | Kg/km | KN | Ohm/km |
|
| 61 | 3.90 | 1999 | 207 | 0.04597 |
|
| 61 | 3.78 | 1878 | 194 | 0.04893 |
|
| 61 | 3.65 | 1751 | 181 | 0.05248 |
|
| 61 | 3.51 | 1620 | 167 | 0.05675 |
|
| 61 | 3.38 | 1502 | 156 | 0.0612 |
Greelely |
| 37 | 4.02 | 1289 | 135 | 0.07133 |
Flint |
| 37 | 3.59 | 1028 | 107 | 0.08944 |
Elgin |
| 19 | 4.71 | 908.3 | 97 | 0.1012 |
Darien |
| 19 | 4.36 | 778.3 | 83.1 | 0.1181 |
Cairo |
| 19 | 3.98 | 648.6 | 69.2 | 0.1417 |
Canton |
| 19 | 3.66 | 548.5 | 58.6 | 0.1676 |
Butte |
| 19 | 3.26 | 435.1 | 46.5 | 0.2112 |
Alliance | 0000 | 7 | 4.77 | 343.2 | 37.8 | 0.2678 |
Amherst | 000 | 7 | 4.25 | 272.5 | 30 | 0.3373 |
Anaheim | 00 | 7 | 3.78 | 215.6 | 23.8 | 0.4264 |
Azusa | 0 | 7 | 3.37 | 171.3 | 18.9 | 0.5365 |
Ames | 2 | 7 | 2.67 | 107.5 | 12.4 | 0.8547 |
Alton | 4 | 7 | 2.12 | 67.8 | 7.83 | 1.356 |
Akron | 6 | 7 | 1.68 | 42.58 | 4.92 | 2.159 |
ASTM-B399 | BS3242 | DIN48021 | SS424 0814 | IEC60189 |
Akron | Box | 16mm² | 31mm² | 16mm² |
Alton | Acacia | 25mm² | 62mm² | 25mm² |
Ames | Almond | 35mm² | 99mm² | 40mm² |
Azusa | Cedar | 50mm² | 157mm² | 63mm² |
Anaheim | Fir | 70mm² | 241mm² | 100mm² |
Amherst | Hazel | 95mm² | 329mm² | 125mm² |
Alliance | Pine | 120mm² | 454mm² | 160mm² |
Butte | Willow | 150mm² | 593mm² | 200mm² |
Canton | Oak | 185mm² | 774mm² | 250mm² |
Cairo | Mulberry | 240mm² | 910mm² | 315mm² |
Darien | Ash | 300mm² |
| 400mm² |
Elgin | Elm | 400mm² |
| 450mm² |
Flint | Poplar | 500mm² |
| 500mm² |
Greeley | Sycamore | 625mm² |
| 560mm² |
| Upas | 800mm² |
| 630mm² |
| Walnut | 1000mm² |
| 710mm² |
| Yew |
|
| 800mm² |
| Totara |
|
| 900mm² |
| Rubus |
|
| 1000mm² |
| Araucaria |
|
| 1120mm² |
|
|
|
| 1250mm² |