-20C weather outlet 90deg.C hot water 3HP 5HP 10HP R134a+R410A industrial air source heat pump
USD $3,992 - $4,002 /Set
Min.Order:1 Set
Jiangsu Sunchi New Energy Co., Ltd.
-20C ambient output 90C hot water R134a +R410A DC inverter heat pump for industrial heating
Amb.-20C outlet 90C hot water R134a+R410A high temp. dc inverter heat pump
Ambient -25C winter 55C heating room save 75% power 12KW/19KW 35KWEVI heat pump water heater
Ambient -25C winter 55C heating room save 75% power 12KW/19KW air source heat pump water heater
Ambient -25C winter 55C heating room save 75% power 12KW/19KW dc inverter air to water heat pump
Ambient -25C winter 55C heating room save 75% power 12KW/19KW 35KW EVI dc inverter heat pump
Introduction-- 90℃ high temperature DC inverter heat pump water heater
1. Flexible high temperature DC inverter heat pump water heater unit with two compressor to producing hot water by two stage coupling operation.
2. Best combination between the R410A excellent low-temperature characteristics and R134A high temperature properties.
3. The first stage using MITSUBISHI motor R410A inverter compressor variable speed operation.
4. Follow the different running conditions and the ambient temperature, let the first stage provides a stable condition for the second stage compression.
5. Then by the second R134a compressor finished heat exchanger to outlet 90℃ water.
6. Suitable for high temperature hot water project and cold area heating project.
7. We sure ours heat pump boiler still outlet 90 ℃ water When the ambient temperature to -20 ℃.
Parameter :
DC inverter heat pump 90℃ high temperature Water heater
| ||||||
Model |
| RSV-12K/S | RSV-20K/S | RSV-40K/S | ||
HP | 3P | 4P | 5P | |||
Power supply | V/Hz | 220V/50Hz | 380V/Hz | |||
Rated heating capacity | KW | 12.0 | 20.0 | 40.0 | ||
Rated heating input power | KW | 3.8 | 6.3 | 12.6 | ||
COP | W/W | 3.2 | 3.2 | 3.2 | ||
Max input power | KW | 7.6 | 12.6 | 25.2 | ||
Max input current | A | 36.0 | 20.5 | 41.0 | ||
Rated hot water yield | L/h | 140 | 230 | 460 | ||
Refrigerant | Type | First stage:R410A,second stage:R134A | ||||
Hot water temperature range | ℃ | 30℃~90℃ | ||||
Working ambient temperature | ℃ | -15℃~45℃ | ||||
Compressor | First stage | Type | MITSUBISH DC inverter | |||
Second stage | Type | R134A high temperature compressor | ||||
Controller system | Type | Hitachi DCBL controller | ||||
Refrigerant-refrigerant heat exchanger | Type | 346L couping high efficient plate heat exchanger | ||||
Water side heat exchanger | Type | 346L high efficient plate heat exchanger | ||||
Throttle way | Type | Electronic expansion valve | ||||
Pressure device | Type | Built-in high and low pressure sensor | ||||
Electronic Component | Type | Schneider AC contactor | ||||
System switching valve | Type | High temperature Solenoid valve | ||||
Noise | dB(A) | 54 | 57 | 60 | ||
N.W/G.W | Kg | 120/150 | 150/180 | 260/300 | ||
Connect pipe size | inch | Rc1" | Rc1" | Rc1-1/2" | ||
Unit Size(L*W*H) | mm | 1110*560*1580 | 1110*560*1580 | 1300*600*2000 | ||
The data in the above table test as following; Heating test condition:ambient temperature (DB/WB):20℃/15℃. Initial water temp.:15℃.output water temperature:90℃. Note:the data in this table are for reference only.please following the name plate parameter of this product.
|
working principle:
The first stage adopts full DC inverter technology,make wide range working environment temperature -20℃~45℃
Unit heat capacity and input power under variable conditions (taking 20KW produce 90℃ hot water as an example)
Product adavantage:
90℃ high temperature heat pump -latest technology -R140A+R134A
(SUNCHI heat pump factory offer the advanced control system to control both R410A+R134A two stage compressor, by the sensitive pressure sensor to feedack control cell system to easy let the machine produce 90℃ hot water even weather is -20℃ winter ).
Application:
About Sunchi Energy Company:
Established in 2005, located in changzhou city , jiangsu province, Sunchi is an professional manufacturer focus on researching, production, service of air source heat pump , ground water source heat pump and solar air conditioner. Sunchi has got the CE,CB,EN14511 certificate from TUV Lab, and also passed the Australia and New Zealand JAS-ANZ certificate, got ISO9001. ISO18001, ISO14001 and CCC certificate. Now applying European ErP EN14825 test report from TUV lab. Currently the products has been exported to Western Europe, North Europe, South Africa, Middle-East, South American and Australia market. Sunchi builded new 75,000 Watts multi-function Enthalpy Difference Laboratory In 2012 year, this lab using to strictly control qulity. Sunchi company offer OEM , ODM co-operation for worldwild business partner , welcome join ours team.
Package and shipment:
1. We can make sure shipment within 20 working days .
2. Strong plywood pallet , carton package for FCL full container loading, strong plywood box for LCL loading .
3. All spare parts together loading into package ,one time finished shipment to buyer.
4.Take video for buyer before package to 100% sure buyer get product same as order , no any different.
5. we offer 100% test online, 5% test in Lab by 24 hours for one lot order (if not new model ).
If you want to know more information about SUNCHI 90 ℃ high temperature DC inverter heat pump water heater, please contact us directly by through the following ways.
Wechat ID: sunchienergy . Skype ID:sales02sc .