Programmable Low Air Pressure Testing machine for automotive electronics
USD $6,000 - $50,000 /Set
Min.Order:1 Set
Guangdong KOMEG Technology Ind Co., Limited
Programmable high altitude low pressure test equipment with Advanced Laboratory Solutions
Programmable high altitude Simulation equipment for solar panels test
Programmable altitude test equipment for Material Physical Damage Testing
Programmable Low Air Pressure Testing equipment Tecumseh Compressor
Programmable high temperature and low pressure combined test chamber for Automotive Testin
Programmable Low Air Pressure Testing machine for automotive electronics
High Altitude Simulation Test Chambers test for the instruments and meters, electrical products, materials, spare parts, equipments, etc at a low pressure, high temperature, low temperature, under the effect of single factor or multiple factors at the same time. Simulation of high-altitude conditions like might be found in mountainous regions. Test for electric performance parameters of the specimen. Mainly used in aviation, aerospace, information, electronics and other industries.
Specifications | |||||
Model | KU-504L | KU-1000L | KU-504S | KU-1000S | |
Inner Size (D*W*H)mm | 800*700*900 | 1000*1000*1000 | 800*700*900 | 1000*1000*1000 | |
Capacity(KW) | 11 | 15 | 16 | 18 | |
Chamber Volume(L) | 504 | 1000 | 504 | 1000 | |
Performance | Temp range | -40℃~+150℃ | -70℃~+150℃ | ||
Temp constancy | ±0.5% | ||||
Temp deviation | ≥100℃, ±3.0℃(at constant pressure with empty load) | ||||
<100℃, ±2.0℃(at constant pressure with empty load) | |||||
Cooling rate | 0.7℃~1.0℃/min(Overall average) | ||||
Pressure range | Constant pressure ~1kPa | ||||
Pressure constancy | When ≥40kPa, ±2kPa, 4kPa~40pKa ±0.5kPa, when≤4kPa, ±0.1kPa | ||||
Depressurization rate | Constant pressure~1kPa≤30mins(Normal temp) | ||||
Pressure recovery rate | 10kPa/Min(adjustable) | ||||
Material | Exterior material | Cold-rolled steel sheet(Rust proof&Plastic Spray treated)/Stainless Steel plate | |||
Interior material | Stainless steel(SUS304) | ||||
Pressurized parts | High quality steel plate(Rust proof & Plastic spray treated) | ||||
Insulation material | High quality glass wool | ||||
Cooling System | Compressor | Semi-Hermetic Compressor | |||
Cooling Mode | Water cooled | ||||
Temp regulating method | Balanced Temperature & Humidity Control System (BTHC) | ||||
Pump | Rotary vane type vacuum pump | ||||
Heater | Iron-chrome wire heater | ||||
Sight window | Circular viewing glass incorporating heat generator | ||||
Temp Sensor | Pt-100 | ||||
Controller | Touch Screen Controller | ||||
Safety Devices | Over pressure, over heat and over current protection for compressor, over temp. protection, over load protection for blower, Hydraulic and Water lack Protection, leakage protection, phase-lack protection, Pump failure alarm | ||||
Standard Accessory | Sight window, Cable Port( 1 located on the left side), Baffle, Baffle frame*2 | ||||
Power | AC380V/50Hz, 3Phase 5 wires+ Ground Wire. | ||||
Note: 1. We reserve the right to change specifications without prior notice 2. Customized sizes and configurations available |
Standard configuration:
Two sample holders; an observation window; φ25 or φ50 cable hole.
Optional parts:
Communication interface RS232 or RS485, logger, micro printer, remote temperature and humidity control system (including printers, communications software, computer), mobile casters.
Structure:
Overall structure, new test chamber designed very easy to operation and maintenance:
Water and electricity system separation design;
External humidifying design;
Three levels of overheat protection, easy access for refrigeration servicing, etc.
Material:
TRUMPF machines for sheet metal processing;
Tecumseh, Bock Compressor;
High quality electronic components (e.g. DANFOSS, ALCO, RANCO, SPORLAN, SAGINOMIYA, Schneider solenoid valve)
Standards Implemented and Met
GB10592-89 Technical requirements for high and low temperature test chamber
GB2423.1-1989 Low temperature test
GB2423.2-1989 High temperature test mode
Thermostat regulator balanced manner BTPC thermostat (regulator) mode
Ambient temperature: 5 ℃ ~ 35 ℃; Humidity: ≤90% RH; Atmospheric pressure: 86-106kPa
Material cold rolled steel shell, surface spray
SUS304 stainless steel inner tank
Rigid polyurethane foam insulation foam glass +
Regulator heater Nichrome heater
Fan shaft seal magnetic fluid flow fan
Refrigeration machinery contraction two binary cascade refrigeration (cooling)
Refrigeration compressor: Semi-hermetic compressors
Refrigerant: R404a / R23
Controller Display: 7 "color screen, liquid crystal display (LCD)
Run the program mode, setting mode
Setting mode Touch (piezoelectric)
Program capacity 32 programs, each up to 800 steps (segments), maximum 999 cycles
Setting range operating temperature range adjustment device according to (limit 5 ℃, the lower limit of -5 ℃)
Display Resolution time: 0.1min; temperature: 0.1 ℃; pressure: 0.1kPa
Enter thermal resistance, pressure sensors
Anti-windup PID control mode
Power: AC380 (1 ± 10%) V (50 ± 0.5) Hz three-phase four-wire protective earth
Maximum power current: (A) 35 35
Safety devices
1. Power owed to reverse protection
2. No fuse switch
3. Dry compustion prevention switch
4. The water protection switch
5. Over-temperature protection
6. Motor overload protection
7. The high-pressure compressor protection
8. The compressor overheating protection
9. The compressor overcurrent protection
10. The vacuum pump overcurrent protection
1. Temperature range from -70 to 170℃
2. Altitude range ground to 100,000 feet
3.External pressure type box body structure and stainless steel tank design, rational air circulation system and scientific layout of heating, refrigerating system.
4.Adopts international brand of imported parts for cooling system to improve operation reliability
5. High precision and stable performance with touch screen controller, friendly Man-Machine interface.
6. Multiple layers of safety device to easy maintenance.
7.Viewing window and cable ports available
8. Vacuum pump sized for climb/dive rate required by application
Altitude chamber working principle
Temperature and pressure range chart
Temperature and humidity range chart
* Inquiry and consulting support.
* Sample testing support.
* Visiting our factory is highly welcomed.
* If you face any problems in future during testing process we promise we will give you a reply within 48 hours and solution provide within 3 working days.
We use PP Film wrapping the test chamber to protect the test chamber from moisture or being scratched first, then use strong plywood case for easyload and transport, and to keep the chambers from potential crash or impact.