Automatic Intelligent Genset Controller Minco 410
USD $1 - $199 /Piece
Min.Order:10 Pieces
Guilin Glminco Intelligent Control S&t Co., Ltd.
Automatic Intelligent Genset Controller Minco 410
Function and Charateristics :
1.Auto start, auto protection, ATS control function
2.Display with RPM, oil pressure, water temperature, oil temperature and etc.
3.Small and exquisite shape,wide-screen LCD display with 128×64 lattice and black-light
4. Chinese and English double language menu,mutual operation, can be set and operated without computer
5.User-defined to the input and output port,timing start or stop function
6.Perfect auto protection,warning details and working statement character display directly,fault record more than 50 items
7. All relay contact capability of strat and fuel is above 10A/250VAC/30VDC,the other is 5A
8. Start time can be annual, monthly, weekly, daily.
9.RS232 communication,attached four remote controlmonitor software.
II. Control parameter list:
1.Analog inputs (9 items)
One phase voltageload one phase currentfrequencypowercoolant temp.oil pressurefuel levelbattery voltagecharge voltage etc.
2.Switch inputs (6 items)
Remote start emergency stop user-defined input 1-4 Optional monitor,low oil pressure high coolant temperature acceleration limit deceleration limit, high oil temperature, low fuel level, alarm non-stop; high fuel leve;l fload charge fail alarm; alarm; alarm non-stop running state alarm stop etc.12 items etc
3.Rely output (7 items)
Fuel start excitation user-defined 1-4 public failure auxiliary stop genset supply automation idle closed idle disconnect pre-fuel warm up acceleration deceleration damper over current high speed low battery pumping alarm etc.16 items
4.Delay setting (22 items)
Delay of cool down; delay of pre-fuel; delay of genset start; delay of idle start; delay of crank interval; delay of idle; stop crank time; acceleration delay; bypass time; delay of auxiliary input 1;delay of energize to stop(ETS)delay of auxiliary input 2 delay of auxiliary input 3overload delaydelay of auxiliary input 4over voltage delay; delay of charge failure delay of over frequency; delay of low battery ; delay of warm updelay of transform deceleration delay
5.System parameter setting (17 items)
Trip frequency output 3 setting start method current ratiooutput 4 setting display mode password setting input 1 setting language choose address input 2 setting back light choose measurement 1 setting input 3 setting;output 1 setting input 4 setting output 2 setting.
III. External Features
1.Size of outsidefront panel(L×WxD) 96x96x9mm
Back shell(LxWxD) 84x84x50 mm
Hole size of installation (L×W)85x85mm
2.Power supplyDC8-40 V,<300 mA
3.Work environment-25~75,relative humidity<95%
N.W.:0.4KG