New generator automatic transfer switch
New generator automatic transfer switch
New generator automatic transfer switch
New generator automatic transfer switch
New generator automatic transfer switch
New generator automatic transfer switch

New generator automatic transfer switch

USD $70 - $100 /Set

Min.Order:1 Set

Supply Ability:
6000 Set / Sets per Month
Port:
Guangzhou Shenzhen
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal

Quick Details View All >

Place of Origin:
Guangdong, China
Brand Name:
CGZ
Model Number:
GZQ1
Max. Current:
63A
Max. Voltage:
690V

Foshan Guangzhu Electrical Co., Ltd.

Business Type: Manufacturer
Foshan Guangdong China
Main Products: Circuit Breaker ,Contactor ,Floor Socket ,Energy Meter ,Timer Switch

Product Details

 

◊◊ New generator automatic transfer switch ◊◊

 

 

 

1. Long lifespan

 

2. High impact resistance material

 

3. Easy to install and wiring

 

4. Autumatic transfer switch

  

5. Competitive price

 

 

 

 

New generator automatic transfer switch

 

 

1.Application

 

GZQ1 series dual power automatic transfer switch(ATS) is terminal type automatic transfer device. It’s suitable for 3 phases 4 wires dual power grid with AC 50/60Hz, rated voltage 400V/230V and rated current up to 63A. When one power goes wrong (only test normal Phase A voltage and reserve Phase A voltage, only test loss voltage or loss phase), it will automatic connect one or several load circuits from one power to the other power automatically, to ensure normal power supply of load circuits.

 

The automatic transfer switch conforms to IEC60947-6-1 and GB/T14048.11

 

 

 

2.Normal conditions for operation & installation

 

Environmental Temperature Condition:-25°C ~+60°C

Installation site is not more than 2000 meters above sea level.

Pollution Level: Grade 3

Installation Category:  3

Vertical installation or horizontal installation

 

 

 

3.Main Parameter

 

Rated Current Ie A

6,10,16,20,25,32,40

50, 63

Electrical Appliances Class

CB

Use Category

AC~33B

Tripping Current

5~10In (Type C), 10~15In (Type D),

Rated voltage Ue

220V (2P),380V (3P or 4P)

Rated frequency

50/60Hz

Rated short circuit connecting ability Icm (Peak)

9.18KA

6.615KA

Rated short circuit breaking ability Icn (effective value)

6KA

4.5KA

 

 

 

4.Founction introduction

 

Function

Basic type

Multifunction type

Full-function type

Manual moda

yes

yes

yes

Automatic moda

yes

yes

yes

Motor protection function

yes

yes

yes

Main contact working position(performing circuit breaker)

 

 

 

Frequency-used power supply closed

yes

yes

yes

Reserve power supply closed

yes

yes

yes

Double portion

yes

yes

yes

Automatic control

Frequency-used power supply indication

yes

yes

yes

Reserve monitoring power supply

yes

yes

yes

Automatic connection and automatic changeover

yes

yes

yes

Automatic connection and non-automatic changeover

no

yes

yes

Reserve for each other

yes

yes

yes

Power grid-power grid

yes

yes

yes

Power grid-generate electricity

no

yes

yes

Phase break instaneous protection

yes

yes

yes

Under-voltage protection 150-210V

adjustable

adjustable

adjustable

Over-voltage protection 230-280V

yes

yes

yes

Voltage loss protection 30%Ue

yes

yes

yes

Fire control function

no

yes

yes

Changeover time delay 0-100s continuous adjustable

yes

yes

yes

Returning time delay 0-100s continuous adjustable

yes

yes

yes

Frequency protection

no

no

yes

Communication function

no

no

yes

Indication

Closed/open/double portion indication

yes

yes

yes

Frequent-use power supply indication

yes

yes

yes

Reserve power supply indication

yes

yes

yes

Fault tripping indication

yes

yes

yes

Parameter setting indication

yes

yes

yes

Voltage real time indication

yes

yes

yes

Normal three phase voltage protection

three phase

three phase

three phase

Reserve three phase voltage protection

three phase

three phase

three phase

 

 

 

 

5.Product photos

 

New generator automatic transfer switch

 

New generator automatic transfer switch

 

New generator automatic transfer switch

 

New generator automatic transfer switch

 

New generator automatic transfer switch

 

 

 

 

6.Installation & wiring

 

ATS can be installed in power control cabinet directly. Users can wire after ATS installation (refer to design and use). As per current value use suitable conductor to connect the mains side (top terminal) and load side (bottom terminal) of MCB of normal electric power and standby electric power. In-phase parallel connection at load side, and ensure the phase sequence of normal electric power and standby electric power must be accordant (Wire as per A,B,C,N sequence). For 3 poles ATS should add one conductor with section not less than 0.3mm2  to connect theneuter line of power supply correctly, thus ATS can work properly. For 4 poles or 2 poles ATS, N pole of normal electric power and standby electric power should be connected to N pole of MCB respectively. In addition, when install ATS please ground reliably at grounding mark.

 

Auxiliary terminal is active contact signal, only used for external connection with indicator to display Off state, should be connected to the indicator directly. Can’t put in power at auxiliary terminal (but for 3 poles ATS should add one conductor with section not less than 0.3mm to connect theneuter line of power supply and the terminals of neuter line on ATS auxiliary terminal. Otherwise ATS can’t work properly.)

 

 

 

7.Use

 

1) Normal use, please set the switch of controller at Automatic Function. Under Auto working the controller of ATS monitor normal electric power and standby electric power and display running status of ATS. When Normal power cut, novoltage, failure, ATS will transfer load automatically from normal power to standby power. If normal power get right, ATS will transfer load automatically from standby power to normal power. The luminous diode on switch panel indicate switch off situation.

 

2) If you don’t adopt automatic transfer or need other manual operation please set the controller at manual. Under manual operation the controller stop work, and manual operation can make the breaker on off, and the switch doesn’t transfer automatically.

 

3) When ATS is short circuit or over load, The MCB of ATS will protect tripping. If power display normally the handle of MCB is switching on. If the MCB has protected tripping users should set at manual and operate the switch to dual separating brake  by hand, and check the reason of trip. After trouble clearing please set the controller at auto again to operate.

 

4) When ATS transfer to auto from manual, if normal and standby power are normal ATS will prior connect normal power to load (even if load connected standby power ago)

 

 

 

8.Matters need to attention

 

When users test or operate please follow relative rules and pay attention to the following matters to ensure use our ATS correctly.

 

1)Neutral conductor N can’t be connected in wrong way, must connect reliably, otherwise ATS can’t operate properly, even burn controller and motor.

 

2)The protective grounding of ATS must be connected reliably to ensure safety.

 

3)Detection sampling signal for controller work power and main power supply is taken from Power supply side of main circuit, and work power of auxiliary connection terminal used for connect indicator is taken from main circuit, so can’t have voltage test between spare terminals (unless dismantle the secondary wires). Can have power frequency voltage test between main circuit and shell or between secondary auxiliary terminals and shell.

 

 

 

 

9.Simple troubleshooting

 

When users find fault can request professional to test and deal with. Keep Away for Safety when operate. Or contact our Specialized Service Departments.

 

1) Double Power are both switched on, but ATS can’t transfer automatically

   1. Check Auto/manual should be in automatic position.

   2. Check if incoming line is correct or not, if phase sequence is accordance or not, and wiring is solid and reliable or not.

   3. Check if the fuse is burned on not.

 

2) Double power are both switched on, ATS standby power is switching on.

   1. Check if normal power incoming line has voltage or not.

   2. Check Commonly used insurance

   3. Check if external light is connected in wrong way or not.

 

 

 

 

10.Defects liability period

 

On the premise of that users comply with the prescriptive maintenance and usage, such products would have a defects liability period of 3 years.

 

 

 

11.Company profile:

 

 New generator automatic transfer switch

 

 

 

12.Professonal production:

 

New generator automatic transfer switch

 

 

 

 

 

Contact us

 

 

Contact us:

How to buy our products?

 

Send your inquiry through our alibaba website,we will reply you at the soonest time;

Or you can call us by:

 

 

 New generator automatic transfer switch

 

 

Our Services

 

 

Our service:

 

1. OEM Experiences above 12 Years in this field.

 

2. Reply your enquiry in 24 working hours.

 

3. Experienced staffs answer all your questions in professional and fluent English.

 

4. Customized design is available. OEM & ODM are welcome.

 

5. Exclusive and unique solution can be provided to our customer by our well-trained and professional engineers and staffs.

 

6. Special discount and protection of sales area provided to your distributor.

 

 

 

 

 

 

Send your inquiry details in the below, click "Send" !! Thank you!

Contact Supplier

Mr. JACKIE QIAN Sales Manager Chat Now
Telephone
86-757-82826898
Mobile
008613929917138
Fax
86-757-82837938
Address
NO.54 LECHENG FIRST ROAD, LE'AN, GUANGFO ROAD, FOSHAN CITY, GUANGDONG PROVINCE, CHINA Foshan,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Switches > Other Switches
Categories
Hi~