10kva complete self-protection single phase transformer
USD $100 - $600 /Piece
Min.Order:1 Piece
Zhengzhou Hongliang Cable Co., Ltd.
34.5kv single phase overhead distribution transformer for 110/220v
Power Transfomer 69kv 16000kva Oil Immersed On Load Tap Changer transformer
S(F)Z11 110KV 31.5MVA YDN11 Three-phase Two-winding On-load-tap-changing Power Transformer
S(F)Z10 132KV 25MVA YNd 11 Three-phase Two-winding On-load-tap-changing Power Transformer
S(F)S9 Three-phase Three Winding Non-excitation-tap-changing 63MVA 121KV Power Transformer
Oil type distribution transformer with OLTC 10 mva power transformer price
About single transformer description:10kva complete self-protection single phase transformer:
10 kva transformers range: 5 kVA to 100kva single phase pole mounted transformer to 333kVA
100kva single phase pole mounted transformer temperature Rise: 55°C or 65°C I
13.2kv power transformer cooling Types: ONAN 100kva single phase pole mounted transformer
13.2kv oil transformer frequency: 50Hz or 60Hz
13.8kv oil transformer high Voltage: 0.6kV to 46kV, up to 250kV BIL, including a
series of multiple voltages
Low Voltage: 120/240 through 15kV
Taps: None or 4-2.5% are standard. Other special
combinations can be provided
13.8kv power transformer HV Bushings: cover and sidewall mounted available in
porcelain, bushing well or epoxy molded style of 100kva single phase pole mounted transformer
13.8kv single phase transformer LV Bushings: cover and sidewall mounted are available in different configurations and types to meet your specific requirements for 100kva single phase pole mounted transformer
13.8kv transformer pressure relief valve or internal fault indicator
Core & coil designs are optimized to provide lowest total
cost of ownership based on your specific needs for single phase pole mounted transformer
10kva complete self-protection single phase transformer standards:
GB1094.1-2-1996,GB1094.3.5-1985 and GB/T6451-1999.
Working conditions
1.Ambient air temperature: -5°C~+40°C, the highest monthly mean temperature should not exceed +30°C;
2.Altitude for installing place should not exceed 2000m;
3.When the ambient air temperature is +40°C, the relative humidity should not exceed 50%, and it allows higher relative humidity under lower temperature. Max average humidity in the dampest month is 90%, meanwhile the lowest average temperature of this month is + 25°C, and condensation on the product surface caused by temperature change should be taken into consideration
10kva complete self-protection single phase transformer Parameters (single phase)
KVA | H.V | Taps | L.V | Loss(W) | DIMENSION(mm) | E | Weight (Wgt) | OIL Qty (kg) | ||||
NO-LOAD | FULL-LOAD | A | B | C | D | |||||||
5 | 13200/ 7620 or 11000/ 6350 or 12470/7200 | +2× 2.5% or 0 | 120 240 480 or 120-240 240-480 | 20 | 105 | 840 | 400 | 480 | 310 |
286
591 | 70 | 16 |
10 | 36 | 184 | 860 | 430 | 510 | 340 | 95 | 22 | ||||
15 | 48 | 250 | 910 | 430 | 510 | 340 | 120 | 25 | ||||
25 | 72 | 360 | 1040 | 480 | 560 | 380 | 158 | 34 | ||||
37.5 | 95 | 495 | 1120 | 560 | 610 | 450 | 240 | 55 | ||||
50 | 116 | 640 | 1245 | 560 | 610 | 450 | 285 | 59 | ||||
75 | 160 | 840 | 1245 | 640 | 680 | 510 | 395 | 76 | ||||
100 | 200 | 1080 | 1270 | 680 | 710 | 510 | 450 | 84 | ||||
167 | 295 | 1600 | 1480 | 960 | 840 | 610 | 610 | 135 |
three phase transformer parameter
Rated capacity (KVA) | Voltage combination | Connection symbol | Loss(KW) | No-load current(%) | Impedance voltage(%) | Weight(Kg) | ||||
H.V.(KV) | High voltage tapping range | L.V.(KV) | load | No-load | oil weight | overall weight | ||||
50 | 20 24 33 35 38.5 | ±5% | 0.4 0.415 0.433 | Dyn11 Yyno Yd11 | 1.21 | 0.21 | 2.00 | 6.5 | 265 | 860 |
100 | 2.02 | 0.29 | 1.80 | 310 | 1150 | |||||
125 | 2.38 | 0.34 | 1.70 | 320 | 1190 | |||||
160 | 2.83 | 0.36 | 1.60 | 360 | 1230 | |||||
200 | 3.33 | 0.43 | 1.50 | 390 | 1300 | |||||
250 | 3.96 | 0.51 | 1.40 | 425 | 1480 | |||||
315 | 4.77 | 0.61 | 1.40 | 460 | 1590 | |||||
400 | 5.76 | 0.73 | 1.30 | 490 | 1760 | |||||
500 | 6.93 | 0.86 | 1.20 | 540 | 2140 | |||||
630 | 8.28 | 1.04 | 1.10 | 620 | 2380 | |||||
800 | 9.9 | 1.23 | 1.00 | 780 | 2800 | |||||
1000 | 12.15 | 1.44 | 1.00 | 910 | 3850 | |||||
1250 | 14.67 | 1.76 | 0.90 | 1060 | 4600 | |||||
1600 | 17.55 | 2.12 | 0.80 | 1210 | 5200 |
10kva complete self-protection single phase transformer packaging Long time shipment & Seaworthy wooden box
Wooden package optional:
1,choose one unit/ wooden box
2,choose 2unit/ wooden box to save cost
10kva complete self-protection single phase transformer service:
1,Quick response in before sales period help you got order
2,Excellent service in production time let you know each step we made
3,Reliable quality solve you aftersale headache
4,Long quality waranty ensure you can buy without hesitate
Zhengzhou Hongliang Cable Co.,ltd is one of the branch of Huadong Cable Group ,and also is biggest professional import and export trade company in China.
The plant was founded in 1998, occupied 50,000 square meters,with advanced equipments of 20 sets production lines and 25 sets testing machines,Annual production capacity is more than 12 million kilometers.
Our international branch is located in Zhengzhou city,which is well-known for convenient transportation . We mainly produce and export power cable, all aluminum conductor(AAC), aluminum conductor steel reinforced(ACSR Conductor), all aluminum alloy conductor(AAAC), overhead Aerial bundled ABC cable,1-66kV power cables(including XLPE insulated cables, PVC insulated cables, SWA/STA armored cables).(XLPE/PVC insulated ABC cable),control cable, welding cable, rubber cable ,mining cables and electrical wires(PVC sheathed flexible cable),transformers,cable lugs etc. These products can be used for power transmission in air,underground and industry,such as power station, railway, agriculture, and estate. Our products honoured I S O 9 0 0 1:2 0 0 2 and CCC,PCCC,SGS,BV certificates. We strictly according to GB,IEC,BS,ICEA, ASTM, DIN, VED, JIS standards to manufacture the products, and also we can design and produce according to customers' requirements.We have exported wires and cables to European, South America, North America, Middle East, Africa, Asia,,Oceania countries and etc.
1.what is our payment term ?
Our payment term is usually T/T 30% in advanced, the balance before picking up the goods or L/C at sight.
2.what is the lead time ?
The lead time usually is 10 - 30 working days.
3.what is the package of the cable ?
The package is usually wooden drum or steel wooden drum or coil.also according to customer’s requirment.
4.Could we provide the free sample for customer ?
Sure, we provide the free sample for customer to checking for 0.4/11kv three phase pole mount transformer oil-filled totally enclosed power transformer