1000LPH RO WATER PURIFICATION SYSETEM
Negotiable /Piece
Min.Order:5 Pieces
RO – PLANT TO 1000 LPH
BASIS OF DESIGN AND CAPACITY
Capacity utilization: 91-95%
INPUTS (Wastewater Quality) To RO Plant:
otal Dissolved Solids: < 1000 PPM
OUTPUT (Treated Water Quality) From RO Plat:
Total Dissolved Solids: < 50 PPM
TECHNICAL SPECIFICATIONS
1 | RAW WATER PUMP |
|
| Purpose | To feed the Dual Media Filter at pressure more than 2.0 bar, which is min. operating pressure for filter. |
| Specifications | a) MOC : CI |
|
| b) Type : Horizontal Centrifugal |
|
| c) Power Required: 1 HP |
|
| d) Electrical : 230 V, Single phase , 50 hz |
|
| e) Make : CRI Or Lubi |
|
| i) Quantity : 1 No. |
|
|
|
2 | DUAL MEDIA FILTER |
|
| Purpose | To remove the total suspended solids, dirt , iron and reduce silt density index which can foul the membranes |
| Specifications | Vessel : |
|
| a) Make: Pentair Roosh OR Equilent b) Material of Construction: FRP c) Diameter: 13” |
|
| d) Height : 54” |
|
| e) Testing Pressure : 10 kg/cm2 |
|
| f) Opening : Top |
|
| g) Quantity : 1 No. |
|
| Valve : |
|
|
|
3 | ACTIVTED CARBON FILTER |
|
| Purpose | To remove the total color, smell, odur, from the water. |
| Specifications | Vessel: |
|
| a) Make: Pentair Roosh OR Equilent b) Material of Construction: FRP c) Diameter: 13” |
|
| d) Height: 54” |
|
| e) Testing Pressure: 10 kg/cm2 |
|
| f) Opening: Top only |
|
| g) Quantity: 1 No. |
Total Solutions For Material At One Place
Loading Pictures