Dual Channel RTD or Thermocouple input/4~20mA or 1~5V output/temperature isolation
Dual Channel RTD or Thermocouple input/4~20mA or 1~5V output/temperature isolation
Dual Channel RTD or Thermocouple input/4~20mA or 1~5V output/temperature isolation
Dual Channel RTD or Thermocouple input/4~20mA or 1~5V output/temperature isolation
Dual Channel RTD or Thermocouple input/4~20mA or 1~5V output/temperature isolation

Dual Channel RTD or Thermocouple input/4~20mA or 1~5V output/temperature isolation

USD $80 - $100 /Piece

Min.Order:20 Pieces

Supply Ability:
100000 Case / Cases per Month
Port:
Ningbo Shanghai
Payment Terms:
T/T

Quick Details View All >

Place of Origin:
Zhejiang, China
Brand Name:
SUPCON
Model Number:
SB3075

Zhejiang Supcon Instrument Co., Ltd.

Credit Member 4 years
Business Type: Manufacturer
Hangzhou Zhejiang China
Main Products: Paperless recorder ,Procss controller ,Pressure transmitter ,Calibrator ,Isolated barrier

Product Details

Dual Channel RTD or Thermocouple input/4~20mA or 1~5V output/temperature isolation

 

mV, THC or RTD input


The SB3075 converts a low-level dc signal from a temperature sensor mounted in the field into two 4/20mA current signals for driving a control-station load. Software-selectable features include configuration, ranging, monitoring and testing for eight thermocouple types, or two kinds of 3-wire RTDs. Each thermocouple model converter has an integral sensor for the purpose of cold-junction compensation. Configuration is carried out through a port inside of the module using and a personal computer. The SB3075 provides dual outputs.

 

Dimension

114.5mm×99.0mm×17.5mm


Number of channels
1   with dual outputs


Signal source
Millivolt Types J, K, T, E, R, S, B or N THCs to IEC584 3-wire PT100 or Cu50 RTDs to BS1904/DIN 43760


Input signal range
-75 to +75mV, or 0 to 450Ω


Input signal span
3 to 150mV, or 10 to 450Ω


Cold junction compensation
Automatic Error: ±1.0℃


Common mode rejection
120dB for 250V at 50Hz/60Hz


Series mode rejection
40dB for 50Hz/60Hz


Calibration accuracy (at 20℃)
(Includes hysteresis, non-linearity and repeatability) Inputs: mV/THC: ±15μV or±0.05% of input value (whichever is greater) RTD: ±80mΩ Output: ±11μA

 

Temperature drifts (typical)
Inputs: mV/THC: ±0.003% of input value/℃ RTD: ±7mΩ/℃ Output: ±1.0μA/℃


Output range
4 to 20mA or 1 to 5V Note: Clear indication should be given in ordering code when 1 to 5V is needed.

 

Control-station side circuit load resistance
0 to 550Ω


LED indicators
One provided for power indication


Power supply
Voltage: (20~35)VDC Current: (with 20mA signal) 44mA at 20V 40mA at 24V 32mA at 35V Power: 1W typical at 24V with 20mA signal

 

Isolation
250V AC/DC between control station and filed circuits

 

Item NameSB3075 high temperature input with dual outputs Supcon signal isolator
MaterialPlastics
Size114.5mm×99.0mm×17.5mm
ColorGreen
Process

Casting,Stamping,Polishing,Filling Silicon Oil,

Painting,Assembly,Calibrating,Packaging

Custom DesighWelcome
ServiceOEM&ODM
MOQ20 pcs
SampleAvailable

Sample Cost,The cost will be returned 

after placing an order

USD 50~80
Sample Lead Time7-15 Days
Payment TermsT/T, LC at sight,west union,paypal
 Packingcarton package with protection material
 Production Time15-30 Days
Delivery PortNingbo or Shanghai

 

 


Dual Channel RTD or Thermocouple input/4~20mA or 1~5V output/temperature isolation

Dual Channel RTD or Thermocouple input/4~20mA or 1~5V output/temperature isolationDual Channel RTD or Thermocouple input/4~20mA or 1~5V output/temperature isolationDual Channel RTD or Thermocouple input/4~20mA or 1~5V output/temperature isolationDual Channel RTD or Thermocouple input/4~20mA or 1~5V output/temperature isolationDual Channel RTD or Thermocouple input/4~20mA or 1~5V output/temperature isolationDual Channel RTD or Thermocouple input/4~20mA or 1~5V output/temperature isolationDual Channel RTD or Thermocouple input/4~20mA or 1~5V output/temperature isolation
Dual Channel RTD or Thermocouple input/4~20mA or 1~5V output/temperature isolation

Contact Supplier

Ms. Jane Yang director Chat Now
Telephone
86-571-86667713
Mobile
13958026850
Fax
86-571-86667711
Address
No.272 Wangshang Road, Binjiang District, Hangzhou, China Hangzhou,Zhejiang

You May Like

New Products

Find Similar Products By Category

Measurement & Analysis Instruments > Other Measuring & Analysing Instruments
Categories