Product Details

VMT700 multi--variable pressure transmitter

Place of Origin Beijing, China
Brand Name VIRVO
Model Number VMT700

Product Features

Specifications

VMT700 multi--variable pressure transmitter can be combined with throttling device, and replace different kinds of transmitters.

Brief introduction:

VMT700 multi--variable pressure transmitter adopts the microprocessor technology, which can measure the differential pressure, pressure , flow rate, and temperature. As a all-digital transmitter, it provides Modbus, HART,Ethernet and other protocols for users to choose, besides, it has a built-in PID controller.

 

Advantages:

1. High accuracy: ±0.075% of span( ± 0.04% of span)

2. High stability: ± 0.01%/year

3. High range ratio: 100:1, 400:1 for max

4. Muti--protocol chocie: RS-232/485, HART, network interface.

5.Reliable:isolated output function, continuing self test,EEPROM write-protection function.

6.Multi-function:replace the three independent differential pressure, pressure and temperature transmitters, making less wiring in the field and more convenient for installation.

7.Built in a variety of standard throttling sets data base and arithmetic, can be combined with orifice, Annubar, and V awl throttling sets.

 

Technical parameters:

 

Physical index:

Material of process interface

Process isolated diaphragm: 316L SS, HastelloyC-276,Monel alloy, Tantalum.

Process interface: 316SS, carbon steel(zinc coating), Hastelloy and Monel alloy .

O-gasket: Teflon, Fluorinated rubber

Bolt: carbon steel, A286 SS (NACE)

 The mounting bracket Carbon steel(zinc coating), stainless steel angle bracket, carbon steel plate bracket
 Filling liquid Silicon oil DC 200 or CTFE
 Shell Epoxy polyester paint,
 Process connection 1/4 NPT, 1/2 NPT adapter(optional)
 Wiring 16AWG(diameter:1.5mm )
 Net weight 6.8 Kg, 8Kg with  accessories .
  Packaging  dimension 234×185×155mm
   Having

 

Electrical parameters

Power voltage

11.9-45 VDC

Signal output

4-20mA DC/HART

HART load resistance

250-550Ω

Insulation voltage

500 Vrms(707VDC)

Damping time

0.25 S

Starting time

5 S

 

Operating condition:

Parameters

Rated temperature

Operating limits

Transportation and storage

Environment temperature(°F) 

-104—185

-104—195.8

-131--257

Body temperature(°F)

-104—230

-104—257

-131--257

Humidity(%RH)

10—85

0--100

0--100

Over-pressure capacity

14MPa, 21MPa for specific

Vacuum degree(kPa)

0

3.5

 

 

System principle graph: 