Personlized Various Switching power supply ac cd adapters 100w 2-20A
USD $2.5 - $20 /Piece
Min.Order:100 Pieces
Shenzhen Greatpower Tech Co., Ltd.
China factory Power switching power supply 96W Output Fast delivery 2-20A
switching power supply AC DC 96W Output Power metal case box 2-20A
2-20A international 96w switching power supply Metal box 1 year warranty CE
international 96w switching power supply Metal box 1 year warranty CE
switching power supply AC DC 96W Output Power metal case box
top grade 96W Output meatl case switching power supply factory driect sale
Personlized Various Switching power supply ac cd adapters 100w 2-20A
1.INPUT CHARACTERISTICS
1)Input Voltage
Nominal Voltage 110/220Vac,Variation Range110/220Vac±20%
2)Input Frequency
Nominal Frequency 50/60Hz, Variation Frequency 47-63Hz
3)Input Current
3Arms max At any input voltage and rated. DC output rated load.
4)Inrush Current
60 Amps Max. Cold start at 240Vac input, with rated load and 25°C ambient.
5)Ac Leakage Current
2mA Max.At240Vac input.
6)Ripple And Noise
The ripple and noise are as follows when measure with Max.Bandwidth of 20MHz and Parallel 47uF/0.1uF, crossed connected at testing point.
7) Turn On Delay Time
2 second Max. AC100Vac input and output Max. Load.
8)Rise Time
40mS Max. At 100Vac input and output Max. Load.
9)Hold Up Time
5mS Min. At100Vac input and output Max. Load.
10)Efficiency:
65% Min. At 110Vac input and output Max. Load.
11)Overshoot:
15% Max. When power supply at turn on or turn off.
2.PROTECTION REQUIREMENT
1)Short Circuit Protection:
3S Max,The charger will be auto recovered when short circuit faults remove.
2)Over current Protection:
The power supply shall be proteced (hiccupped & power reduced) when any output operating
in overload condition (set@ Max.16A) under any line condition for an indefinite period
of time. The power supply shall be self-recovery when the fault condition is removed
3.ENVIRONMENTAL REQUIREMET
1)Operating Temperature: 0°C to 40°C,Full load, Normal operation.
Storage Temperature):-20°Cto 85°C
2)Relative Humidity:
5%(0°C)~90%(40°C)RH,72Hrs,Full load, Normal operating.
3)Vibration:
Operating: IEC 721-3-3 3M3
5~9Hz,A=1.5mm
4)Transportation:
IEC 721-3-2 2M2
5-9Hz,A=3.5mm
9~200Hz,Acceleration=5m/S2
200~500Hz,Acceleration=15m/S2
Axes,10 cycles per axis.
No permanent damage may occur during testing.
The product has to restore to its original situation after power off/on.
4.SAFETY AND EMC REQUIREMENT
DIELECTRIC STRENGTH(Hi-Pot):Primary to secondary,1500Vac/5mA/60s.
5.SOME MODEL REPRESENT
18W | S-18 | 12V 1.5A |
24V 0.75A | ||
24W | S-24 | 12V 2A |
24V 1A | ||
45W | S-45 | 12v 3.75A |
24V 1.86A | ||
60W | S-60 | 12V 5A |
24V 2.5A | ||
120W | S-120 | 12V 10A |
24V 5A | ||
180W | S-180 | 12V 15A |
24V 7.5A |
6. PRODUCT DETAILS
7.PACKAGE TEST:
Our empty carton can bear 1 person's pressure
8,CERTIFICATION
Orignal Switching power supply 12v 100w ac dc adapters 1 year warranty !I