Medical Baby Digital Nipple Pacifier Thermometer
Please Read Carefully Before Use:
Specification
Bettery: DC 1.55/1.5v (SR41/LR41)
Power Consumption: 0.2mW
Battery Life: More than 200 hours of continuous operation. (Approx. 2 years if used 10 minutes per day)
Display Unit: 0.1ºC/ 0.1ºF
Measuring Range: 32.0ºC~42.9ºC (90.0ºF ~109.9 ºF).
Less than 32ºC/ 90ºF, LoºC / LoºF Display
More than 42.9ºC/ 109.9ºF, HiºC / HiºF Display
Accuracy: ±0.1ºC(±0.2ºF) between 35ºC~42ºC (95ºF~106.0ºF), ±0.2ºC(±0.4ºF) for remainder of range at room temperature of 22ºC (71.6ºF)
Dimensions: 48mm x 55mm x 36mm
Weight: Approx. 15g (including battery)
Nipple Size: Medium
Caution
- Any pacifier wears out. TO PREVENT POSSIBLE CHOKING HAZARD, test the strength of the nipple by pulling on the bulb portion before each use.
- Do not bend or temper with the probe and the Thermometer.
- Do not store the Thermometer under direct sunlight or at high temperature area.
- Temperature should be taken under adult supervision. Do not let children play with the Thermometer.
- When the battery is almost exhausted, the symbol ( ) will appear in the display window, meaning that the Thermometer needs to be replaced.
- Oral temperature readings are GENERALLY 0.5°C (1.0°F) lower than actual body temperature readings.
- This Thermometer is designed for use with the Pacifier only. Do not use this Thermometer for any measurements other than explained in this instruction.
- Components may be harmful if swallowed. Contact your physician immediately should this occur.
- The Pacifier Nipple comes in one size intended to fit all mouth sizes. Please gauge your child's mouth size and the nipple size prior to thermometer use. A child using a nipple that is too large has an increase risk of choking.
CARE INSTRUCTION:
- Inspect the pacifier before and after each use. Throw away the pacifier if any sign of worn, damaged or punctured by biting is shown.
- Install the Thermometer only when temperature taking is needed. Remove and store the Thermometer out of reach of children.
- Do not boil or wash the Thermometer.
- Wash and sanitize the pacifier only by washing in hot water with gentle detergent, rinse thoroughly and boil in and open pan of water for 2 minutes.
How to Operate
- Install and check that the Thermometer is secured into the Pacifier. If not, follow the installation instruction below.
- Press the ON/OFF button and the display will read "188.8E", confirming that the display is working.
- Upon releasing the on-off button, last measured temperature will be showed for about two seconds with letter “M” under the degree sign, then 37.0ºC/98.6ºF, and then LoºC/LoºF displayed (if the room temperature is greater than 32ºC/ 90ºF, it will be displayed rather than LoºC/ LoºF). The flash ºC/ºF indicates the thermometer is ready to take a temperature.
- Position the pacifier bulb into baby's mouth as normal pacifier.
- Note: Drinking or eating prior to use may affect the reading. Measurement should be taken one and half hours after eating or drinking.
- After the degree sign (°C or °F) on the display has stopped flashing (approx. 3 minutes), the alarm will sound Bi—Bi—Bi. If temperature exceeds 37.8ºC/100ºF, it sounds Bi-Bi-Bi ---Bi-Bi-Bi. It represents that the Pacifier Thermometer has detected the baby’s temperature and the reading is reflecting the baby’s oral temperature.
- It is recommended to leave the thermometer in baby's mouth for 6- 8 minutes to allow the pacifier nipple to warm up and to get more accurate reading.
- The Thermometer will automatically turn off in 10 minutes. However, to prolong battery life. It is recommended to press the ON/OFF button to turn it off after each use.
- Repeat operation procedures if interrupted during use.
TO DETACH THE THERMOMETER
- While holding the pacifier shield with one hand, rotate the Thermometer counterclockwise until the pointer is pointing to “Open” or “Unlock” position. (LCD display unit is vertical, 90°C, from the pacifier.)
- Pull the Thermometer straight up until the probe is totally removed from the pacifier.
- Do not bend or temper with the probe or the Thermometer.
TO INSTALL THE THERMOMETER
- While holding the pacifier shield with one hand, insert the probe and shaft into the hole at the back of the pacifier.
- Rotate the Thermometer clockwise until you feel the snap. (LCD display unit should be horizontal to the pacifier and the pointer is pointing to the “Close” or “Lock” position.)
Patents:
USA 5,743,647
GERMANY 297 22 903.6
FRANCE 2 773 216
ITALY 00238148
TAIWAN 152115
CHINA ZL 97 2 48791.3