Specifications
1.Water/air/oil cooled
2.DSP digital control
3.DC or pulse current
4.Control by hand, remote control
5.Switch mode technique
1. Main technical parameters
- Input: 3 phase 380V(±10%),50Hz
- Output power: 0~90kW adjustable
- Output current: 0~7000A adjustable
- Output power stability: ≤1%
- Output current stability: ≤1%
- Power factor: ≥0.93(Full load)
- Entire power supply efficiency: ≥90%(Full load)
- Cooling mode: water-cooling, air cooling or oil cooling
- Structure: single cabinet, internal power unit parallel connected
- Control mode: constant power or constant current is selected through switch (constant power and constant current could be switch with interference). Output current has zero start function.
- Working mode: long time full load continuous operation.
- Level of protection: IP50
- Load grade: I
- Insulation grade: B
- Protections: over heat, input overvoltage and under voltage, output overvoltage, output over current, driving failure protection, water underpressure, protection of positive and negative bus bar’s short-circuit to earth.
2. Working condition
- Used indoor, ambient temperature: -100°C~+400°C
- Three phase input power supply requirements:
- AC 380V±10%
- Three phase power imbalance degree is less than 5%.
- Follow the national power quality standard.
- Cooling water requirements:
- Inlet water temperature is within 20°C~30°C,not higher than 35°C
- Inlet water pressure is within 0.2~0.3MPa, outlet water pressure is less than 0.05MPa, PH value is within 6~8, water quality: Resistivity≥20kΩcm; water flow: not less than 45 liters/min
- Environment relative humidity: ≤90%(relative to 20±50°C)
- Elevation: less than 2,000 meters.
- There shouldn’t be excessive amount of dust, explosive gas in the air.
- The installation place should be without severe vibration, the vertical gradient shouldn’t exceed 5%. The seismic intensity of the installation site is less than 7 on the Richter scale.
- Saturated vapor pressure: daily average value is less than 2.2×10-3Mpa, monthly average value is less than 1.8×10-3Mpa.
3. Working principle diagram
4. Inside main components:
- Include high frequency transformer, Rectifier Bridge, IGBT, inverter, DSP, Breaker, Touch screen and so on.
- These components are reliable quality, outsourced from famous manufactures.
5. Display and operation through touch screen
6.Application:
- Chrome plating, zinc plating, copper plating
- Electrolysis of copper, aluminum copper, lead, salt
- Silicon growth
- Sapphire grow
- Anodizing
- Water treatment