1000mA constant current T8 tube led power driver supply
Negotiable /Piece
Min.Order:500 Pieces
Shenzhen Dadekan Electronics Co., Ltd.
1000mA constant current T8 tube led power driver supply
MODEL | DEK-TP40B-420100 | ||||
Input | Input Voltage | 90VAC~305VAC | |||
Voltage Range | 100VAC~277VAC | ||||
Start-up Voltage(-25~70℃) | 90VAC | ||||
Frequency Range | 47Hz~63Hz | ||||
Power Factor(@25℃) | >0.9@220VAC, Full Load | ||||
AC Current (@25℃) | 0.5A @100VAC Full Load | ||||
Inrush Current (@ 25℃) | 50A @305VAC Full Load | ||||
Output | Output Voltage Range | 30V~42V | |||
Output Current | 1000mA | ||||
Output Power | 30~42W | ||||
Conversion Efficiency (@25℃) | 86% @220VAC, Full Load | ||||
No-load Output Voltage | 45V Max. | ||||
Line Regulation (@-25~70℃) | ±5% | ||||
Accuracy Constant(@-25~70℃) | ±5% | ||||
Set-up Time(@25℃) | 3S Max.@100~277VAC, Full Load | ||||
Temperature Coefficient(@-25~70℃) | ±0.03%/℃ | ||||
Overshoot (@-25~70℃) | ±5% No-load Rated Voltage | ||||
Output Ripple & Noise | 0<Ta≤70℃ | ≤4.5VP-P | |||
-25≤Ta≤0℃ | / | ||||
Protection (-25~70℃) | Input Electrical | Low Voltage Protection | / | ||
Over Voltage Protection | / | ||||
Output Electrical | Shorted Circuit Protection | Hiccup, Auto Recovery | |||
No-load Protection | Constant Voltage | ||||
Over Temperature Protection | / | ||||
Environmental Requirement | Storage Temp. & Hum. | -20℃~70℃; 10%~95%RH No condensing | |||
Operating amb. Temp. & Hum. | -10℃~45℃; 20%~90%RH No condensing | ||||
Altitude | 3000m | ||||
EMC | Isolation Resistance | Input--out: 50M OHMS | |||
Withstand Voltage | Input--out: 3KVAC/5mA | ||||
Safety Standards | IEC 61347-2-13/GB19510.14/UL8750 | ||||
EMI | CE | EN 55015:1998,+A1:2000 +A2:2003,CLASS B | |||
RE | EN 55015:1998,+A1:2000 +A2:2003,CLASS B | ||||
Harmonic Current | EN6100-3-2 | ||||
EMS | CS | EN61000-4-6 | |||
RS | EN61000-4-3 | ||||
SURGE | EN61000-4-5 Test: Power Line to Line:500V | ||||
Voltage fluctuations&flicker | EN61000-3-3 | ||||
Power Frequency Harassment | EN61000-4-8 | ||||
EFT | EN61000-4-4 | ||||
Other | Dimensions (L * W * H) | 380mm X 17mm X 10mm;±1mm | |||
Cooling Method | Ventilation Cooling | ||||
Reliability | Burn-in | The power supply shall go a minimum of 4 Hours burn-in test under full load condition. | |||
Design MTBF | 20.000Hrs @25℃, MIL- HDBK- 217 Method 2 Components Stress Method | ||||
Design electrolytic capacitor life | 17520Hrs @50℃ Full load and units continuously working | ||||
Note | 1. Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 2. Test spare parts: test voltage for 500 VDC, 65% RH @ 25 ℃. 3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. | ||||
Minimum Negative Load Requirements | None | ||||
Accessories | / |