1000mA constant current T8 tube led power driver supply
1000mA constant current T8 tube led power driver supply

1000mA constant current T8 tube led power driver supply

Negotiable /Piece

Min.Order:500 Pieces

Supply Ability:
800 Piece / Pieces per Month
Port:
Shenzhen
Payment Terms:
T/T

Quick Details View All >

Place of Origin:
China
Brand Name:
DADEKAN
Model Number:
DEK-TP40B-420100
Output Power:
Other, 30~42W
Output Type:
Single
Input Voltage:
Other, 90VAC~305VAC

Shenzhen Dadekan Electronics Co., Ltd.

Business Type: Manufacturer
Shenzhen Guangdong China
Main Products: LED driver ,LED power supply ,switching power supply ,LED Driver Power Supply ,Constant Current Source

Product Details

1000mA constant current T8 tube led power driver supply

 

MODEL 

DEK-TP40B-420100

Input

Input Voltage

90VAC~305VAC

Voltage Range

100VAC~277VAC

Start-up Voltage(-25~70℃)

90VAC

Frequency Range

47Hz~63Hz

Power Factor(@25℃)

>0.9@220VAC, Full Load

AC Current (@25℃)

0.5A @100VAC  Full Load

Inrush Current (@ 25℃)

50A @305VAC  Full Load

Output

Output Voltage Range

30V~42V

Output Current

1000mA  

Output Power

30~42W

Conversion Efficiency (@25℃)

86% @220VAC, Full Load

No-load Output Voltage

45V  Max.

Line Regulation (@-25~70℃)

±5%

Accuracy Constant(@-25~70℃)

±5%

Set-up Time(@25℃)

3S Max.@100~277VAC, Full Load

Temperature Coefficient(@-25~70℃)

±0.03%/℃

Overshoot (@-25~70℃)

±5%  No-load Rated Voltage

Output Ripple & Noise

0<Ta≤70℃

≤4.5VP-P

-25≤Ta≤0℃

/

Protection

(-25~70℃)

Input Electrical

Low Voltage Protection

/

Over Voltage Protection

/

Output Electrical

Shorted Circuit Protection

Hiccup, Auto Recovery

No-load Protection

Constant Voltage

Over Temperature Protection

/

Environmental 

Requirement

Storage Temp. & Hum.

-20℃~70℃; 10%~95%RH  No condensing

Operating amb. Temp. & Hum.

-10℃~45℃; 20%~90%RH  No condensing

Altitude

3000m

EMC

Isolation Resistance

Input--out: 50M OHMS

Withstand Voltage

Input--out: 3KVAC/5mA

Safety Standards

IEC 61347-2-13/GB19510.14/UL8750

EMI

CE

EN 55015:1998,+A1:2000 +A2:2003,CLASS B

RE

EN 55015:1998,+A1:2000 +A2:2003,CLASS B

Harmonic Current

EN6100-3-2

EMS

CS

EN61000-4-6 

RS

EN61000-4-3

SURGE

EN61000-4-5  Test: Power Line to Line:500V

Voltage fluctuations&flicker

EN61000-3-3

Power Frequency Harassment

EN61000-4-8

EFT

EN61000-4-4

Other

Dimensions (L * W * H)

380mm X 17mm X 10mm;±1mm

Cooling Method

Ventilation Cooling

Reliability

Burn-in

The power supply shall go a minimum of 4 

Hours burn-in test under full load condition.

Design MTBF

20.000Hrs @25℃, MILHDBK217 Method 2 Components Stress Method

Design electrolytic capacitor life

17520Hrs @50℃ Full load and units 

continuously working

Note

1Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor.

2Test spare parts: test voltage for 500 VDC, 65% RH @ 25 ℃.

3The SPS is considered a component which will be installed into final equipment. 

The equipment must be re-confirmed that it still meets EMC directives. 

Minimum Negative 

Load Requirements

None

Accessories

/

 

Contact Supplier

Ms. Sophie Sun Chat Now
Telephone
0086-755-27820239
Mobile
13631637512
Fax
0086-755-28720259
Address
D.Building, Tongkangfu Industrial Zone, Yingrenshi Village, Shiyan Shenzhen,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Power Supplies > Switching Power Supply
Categories
Hi~