Climatic xenon test chamber
USD $7,500 - $9,500 /Piece
Min.Order:10 Pieces
Guangdong Sanwood Environmental Chambers Co., Ltd.
Name: Xenonlamp Weather Resistance Test Chamber
Model: SM-800XD
Product name | Xenon lamp weather resistance test chamber |
Application | 1, Adopt xenon arc lamp which can simulate sunlight spectrum to reproduce destructive light waves exsiting in different environments so as to provide the corresponding environment simulation and acceleration test for scientific research, product development and quality control.
2, Suitable for new materials selecting, improve current materials or evaluate material compositions changing durability tests, simulates the material changing when it expose to sunlight in different environmental conditions. |
Structure | 1, The housing adopts quality A3 steel panel (t=1mm) with CNC machine processing, housing surface processing with spraying plastics be much bright clean. 2, The liner is made of imported SUS304 stainless steel panel (t=1mm). 6, Xenon lamp adopts upper fix form, can test 32” product. 8, Inspection window adopts multi hollow tempered glass which can inspect the test process clearly. |
Function | 1, Full spectrum xenon lamp.
|
Techinical Data:
Model | SM-800XD | |
Internaldimension (D×W×H) | 650×800×850mm ( can be customized) | |
External dimension (D×W×H) | 1070×1260×2050mm | |
Power | 6.5KW | |
Performance parameter | Temperature range | RT+10℃~85℃ |
Humidity range (brightness) | 10%~78%R.H | |
Humidity range (darkness) | 10%~98%R.H | |
Spraying time | 1~9999 hours, 59 minutes adjustable | |
Spraying period | 1~240 minutes, interval (cut-off) | |
Spectral wavelength | 290nm~800nm | |
Light irradiancedeviation | ±0.01 W/m2 | |
Irradiance | 150~1500W/m2 | |
Irradiatometer | Accord with test requirements | |
Light irradiance adjusting | Automatic calibration | |
Xenon lamp power | 1KW, 6KW(lifespan: 1600 hours) | |
Temperature and humidity running system | Accuracy range | Setting/direction accuracy: temperature ±0.1℃, humidity ±1%R.H |
Sensor | Platinum resistance: PT100Ω/MV | |
Heating system | Independent system, nichrome electrical heater | |
Humidification system | External insulation, stainless steel surface evaporative humidifier | |
Black panel temperature | 40~110℃ | |
Water supply system | Self-filtrator, auto control humidification, water supply, and xenon lamp cooling circulating water. | |
Temperature controller | Adopt Weinview color touch screen and SiemensPLC modules controller | |
Recycle system | Temperature resistance, low noice, air-condition motor, multi-vane centrifugal impeller. | |
Exterior material | Carbon steel panel with phosphide static spraying plastics processing | |
Materials | Interior material | SUS304 stainless steel panel |
Specimen holder material | SUS304 stainless steel bar | |
Door frame thermal insulation | Anti-heating,anti-aging silicon gel sealing strip | |
Safety Protection | Electric leakage, short circuit, water shortage, motor overheating, over-current protection. | |
Mains Input | AC380V±10%, 50±0.5Hz, three-phase five-wire system |
Structure Characteristics:
1,Test rack adopt SUS304 stainless steel panel 1 set (960 MM ±3MM)
2, Touch screen human machine interface procedure as below:
| Operation interface: test interface to proceed test. |
| Condition setting: running condition setting, including continue lighting, dark cycle, rainfall period, total test time and total exposure energy. |
| Date & time: system time and date setting interface. |
| Trend chart: current and previous trend charts supervising with access temperature, humidity, voltage, illuminance. |
| Controller: system temperature/humidity parameter setting. |
| Performance test: manual operate the system elements. |
| Alarm message: inquire the time and cause with anomaly. |
3, Standard configuration:
| 6500W water-cooling xenon arc lamp: 1 pcs |
| Digit display black ballthermometer (BPT) 0.0~120.0 ℃: 1 set |
| Test holder: 38 pcsSUS304 stainless steel panels, two-layer on each pcs,76 pcs can be placed. |
| Attach particular operating manual and professional direction operating instructions |
| The third-party adjusting report. |
4, Test Specimen Limitation:
| Test samples of inflammable, explosive material, easy to volatile material are forbidden; |
| Storage corrosive substances test sample is forbidden; |
| Storage biological test is forbidden; |
| Storage strong electromagnetic emission source for test sample or storage are forbidden; |
5, Standard Test meet Condition:
| GB/T4797-2006 / IEC 60721-2-4:2002 electrician electronic product solar radiation and temperature under the condition of natural environment |
| GB/T3511-2008/ISO 4665:1998 Vulcanized rubber or thermoplastic rubber weather resistance |
| B/T 2423.24/1995 / IEC68-2-5:1975 Electronic Electrician Product Environmental Test |
| GB-T5170.18-2005 Electronic Electrician Product Environmental Test Equipment basic parameter calibration method temperature / humidity combination cyclic test equipment. |