IEC 60529 Rain chamber
IEC 60529 Rain chamber
IEC 60529 Rain chamber
IEC 60529 Rain chamber
IEC 60529 Rain chamber
IEC 60529 Rain chamber

IEC 60529 Rain chamber

USD $7,500 - $8,500 /Piece

Min.Order:10 Pieces

Supply Ability:
100 Piece / Pieces per Month
Port:
SHENZHEN
Payment Terms:
T/T

Quick Details View All >

Place of Origin:
Guangdong, China
Brand Name:
SANWOOD
Model Number:
SM-LY-1000C-SPEC
Power:
Electronic
Usage:
Auto Testing Machine

Guangdong Sanwood Environmental Chambers Co., Ltd.

Business Type: Manufacturer,Trading Company
Dongguan Guangdong China
Main Products: temperature and humidity test chamber ,Cold and Thermal impact test chamber ,tensile test chamber ,temperature rapid chamge test chamber ,sand and dust test chamber

Product Details

IPX5 rain proof test machine simulates the water drip environment to test the water resistance and sealing of the samples during storage, transportation and usage. It is widely applied to electrical and electronic products, lamps and lanterns, electrical cabinet, electrical components, automobile, motorcycle and ispare parts & other products.

 

It provides the basis to improve the performance of the products. Protected against water jets - Water projected at all angles through a 6.3mm nozzle at a flow rate of 12.5 liters/min at a pressure of 30kN/m2 for 3 minutes from a distance of 3 meters. Meet the requirement of IEC60529 standard IPX5 water pouring test and IPX6 water jet test.

 

Widely used for electric products assessment, shell and seal in the rain environment can ensure that equipment and components good performance test. This product uses scientific design, makes the equipment can realistic simulation drop of water, water spray, splash water, water spray, etc., various kinds of environment. Into the comprehensive control system and the adoption of the frequency conversion technology, which makes the rainfall test product frame rotation Angle, jet pendulum rod swing Angle of water quantity and the oscillating frequency can be automatic control.

 

Chapter 1: The main technical parameters for SMC-LY-1000C

01.

Equipment performance: Products performed as the test equipment for waterproof & water resistance for products.

02.

Product Name: Programmable IPx5 Waterproof Test Chamber

03.

Machine Model: SMC-LY-1000C

04.

The dimensions 1000 x 1000 x1000mm (D x W x H)

05.

Volume 1000L, Gross Weight: 400 kgs

06.

External dimensions of approximately 1250 x 1500 x 1380 mm (D x W x H)

07.

Test bench area: Ø500mm.

08.

Pore size: the number of holes 25

09.

Swing pipe sprinkler aperture: Ø 0.4mm

10.

Water hole spacing: 50mm; (can be adjusted)

11.

Spray ring radius: R400mm; Water spray hole spacing: 50mm;

12.

Sprinkler pipe diameter: Ø16mm;

13.

Pendulum swing angle tube width: 0-270 °

14.

Swing speed: 60°/s adjustable

15.

Spray pressure: 0~400Kpa adjustable

16.

Water supply quantity: According IPX3/4, IPX5/6 adjustment;

17.

Speed test bench: 1 ~ 10r / min.

18

Spray volume: 0.07(1±5%)L/min (Every hole in average)

19

Spray nozzle: Spherical laser drilling,direction: 360°adjustable, make injection of rain fan, to spray the specimen

20

Specimen rotative speed: 4~17rpm (Adjustable)

 

IEC 60529 Rain chamber

 

 

Chapter 2: Mechanical structure design:

01.

Using a programmable controller PLC touch screen control, control pendulum tube angle, swing frequency, the turntable speed, select the spin tube and put the tube, and the cycle time is set, the control system is equipped with Schneider execution components.

02.

Outside box material: Using galvanized sheet with advanced powder paint or Heatproof and cold resistant steel plate (SUS # 304)

03.

Placed tubes, pipes and turntable spin independently of the control system, select the pendulum tube coils can not start, choose the pendulum tube coil can not start. The time set to control several independent systems, respectively. With a water filter, import execution components.

04.

The oscillating tube: The motor / inverter drive reducer / eccentric institution / rack gears and other mechanical Tuan action implementation. Adjust the pendulum tube using the frequency count (per unit time), adjust the angle of the eccentric body.

05.

Work rotation: motor driven worm gear rotates with the drive speed to 5 ~ 17r / min, with anti-rain test piece at the coupling interface.

06.

Nozzle: Depending on the size of the specimen to determine the bending radius of the oscillating tube. Special nozzle for detachable nozzle spray holes can be replaced at any time in accordance with the standard requirements of the aperture to allow uniform droplets emitted, adequate traffic.

07.

Water tank: stainless steel tank with water pumps, water filters, water float valve, drain valve, such as the need to be heated, the tank can also be fitted. Electric heating and temperature control. Can be automatically backwater, circulation type.

 

Chapter 3: Pendulum tube rain test ways : IPx3

01.

Swing pipe sprinkler Aperture: ø0.4; Test time: 10min

02.

Water hole spacing: φ50mm

03.

Spray radius of the ring: φ500 (mm); Sprinkler pipe diameter: ø16mm

04.

Pendulum swing angle tube width: ± 45 ° ± 60 ° ± 90 ° ± 180 ° (IPX3 pendulum tube angle: 60 degrees left and right, a total of 120-degree swing tube rain).

05.

Swing speed adjustment: 0 to 30 rpm / min (adjustable)

06

Rain water pressure: 0.1 ~ 6bpa adjustable

07

Water supply quantity: Under 4bar pressure, flow to 39.2L / min

08

Test rig speed: 0 ~ 20 rpm / min (adjustable)

09.

Test bench area: ø400mm, bearing the weight of 15Kg, rack 0 ~ 300mm adjustable. (Blowhole to sample distance) There are power lead test holes, external power supply box on 11, another spray point in time can be adjusted.

 

IEC 60529 Rain chamber

 

IEC 60529 Rain chamber

 

IEC 60529 Rain chamber

 

Chapter 4: IPx5 & IPx6 Waterproof test device technology parameters:

01.

(1).Meet the EN60529 / IEC529 standards of IPX5 and IPX6 the flush nozzle each set (including corrugated hose, hand valve, pressure device: water pump, two sets of, independent, this device another independent installation and adjustment of water flow back to relief valves.)

02.

(1)IPX5: spray holes of 6.3 mm, adjustable amount of water, can meet the 12.5 L/min (100 L/newspapers) + 0.625 L/min; The nozzle surface distance from shell specimen should be 2.5 ~ 3 m;

(2)Test method: the center of water from the nozzle diameter at 2.5 m for 40 mm circle, specimen surface water every square metre shell time about 1 min, test specimen at least 3 min,

03.

(1)IPX6: spray holes of 12.5 mm, adjustable amount of water, can meet the 100 L/min (6000 L/newspapers) + 5 L/min; (2)Test method: the center of water from the nozzle diameter at 2.5 m for 120 mm circle, specimen surface water every square metre shell time about 1 min, (3)Test time: at least 3 min, (4)The nozzle distance: the nozzle surface distance from shell specimen should be 2.5 ~ 3 m;

04.

The IPX5/6 amount of water is adjustable, can achieve 100L/min; (6000L/hour ±5L/min)

 

IPX5 Test Methods: There's a 120mm circle at separately nozzle at 2.5 m in the main water flow, the water spray time is about 1 min per m2 at the sample shell. The time is at least for 3 min, the space between spray nozzle and sample shell is about 2.2~3m;This equipment contains the water tank.

 

IPX6 Test Methods: Test equipment and test condition: water tank. The dimension should be make the sample in the water tank, the bottom of the distance to the surface at least 1 m. The distance from top of sample to the surface should be at least 0.15m. Test time: 30 min

 

IPX7 Test Methods: Test equipment and test condition: water tank. The dimension should be make the sample in the water tank, the bottom of the distance to the surface at least 1.5m.

 

IEC 60529 Rain chamber

 

Chapter 5. Control System /5-1 The controller combination

01.

Types & Parameter :

Korea TEMI1700 controller

02.

Controller Origin :

Touch Screem System

03.

Features Controller 01:

Detachable display and control unit

04.

Features Controller 02:

Heat and Cool Control Support

05

Features Controller 03:

Humid and De Humid Control Support

06

Features Controller 04:

The touch interface like the picture clear quality

07

Features Controller 05:

18bit A / D converter through a high precision control

08

Features Controller 06:

120 patterns with 1200 segment operating various programs

09

Features Controller 07:

DI 16 points , DO 12 + 20(option) points built in

10

Features Controller 08:

Displays humidity automatic, manual selection

11

Features Controller 09:

In High temperature and humidity, low temperature and humidity, the differentiation of humidity control

12

Features Controller 10:

Digital recorder function

13

Features Controller 11:

Users screen configuration support

14

Features Controller 12:

SD memory card support

15

Features Controller 13:

Provided free of charge to PC Software

16

Features Controller 14:

VESA Mounting Support

17.

Features Controller 15:

Korean, English, Chinese, Japanese, Russian support

 

Chapter 6. Safety Protection System

01.

Leakage and surge protected :

Leakage circuit breaker to prevent leakage protection electronic surge protection.

02.

Prevent power surge protection :

AC power primary side controller with arrester ZRN device

03.

Overload protection device :

(1)Three-phase AC power supply owe. Reverse phase overcurrent protection with the load (overload) ;

(2)High temperature operation control over temperature protection, high temperature, low temperature over-temperature protection settings

04.

Compressor protection :

(1) Refrigerant pressure protection and overload protection devices.

(2) Refrigerant pressure protection and overload protection devices.

(3) Internal compressor overheating protection.

(4) High and low pressure compressor protection.

(5) Compressor start abnormal protection.

(6) Compressor oil differential protection.

05

Fault exception protection :

Turn off the power , malfunction indication and alarm output signal when a fault exception occurs.

06

Protection comment :

(1) A group of humidification barrel dry protection switch.

(2) A group of humidification reservoir when water level is too low to protect.

(3) A group of heating system protection switch.

(4) Heater circuit protection.

(5) Temperature and humidity over equilibrium devices.

 

IEC 60529 Rain chamber

 

IEC 60529 Rain chamber

 

IEC 60529 Rain chamber

 

IEC 60529 Rain chamber

 

For above "Rain Chambers" items, Please kindly contact with us freely. We are here to support you online any time. If you have any questions, We can have a talk ! Thanks for your inquiry ! We are partners ! Thank you.

 

 

Contact Supplier

Telephone
86-0769-81182799
Mobile
86-13412063066
Fax
86-769-82987199
Address
Sanwood Industrial Park,Yuanjiangyuan,Changping Dongguan,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Testing Equipment
Categories
Hi~