Handhled Pulse Oximeter, USB Port and AC Adaptor
USD $200 - $250 /Set
Min.Order:50 Sets
Features:
1. Handheld, compact, easy for carrying and handling
2. Intelligent parameter monitoring interfaces, measuring SPO2, TEMP, PR & PLETH
3. Clear and bright color OLED in real time display, displayable in big font and big screen
4.Unique software for telemonitoring by transmitting data synchronously via internet
5. Long time monitoring and sleeping monitoring
6. Storage/Review trend data up to 3888 groups, data save time interval setable
7. History data uploading to PC for review, printing or storage
8. Audio and visual alarm when parameters exceeded and sensor-off
9. Built-in rechargeable Li-ion battery, up to 15-hour running time
10. Two types for charging battery: USB port for recharged by PC or by AC adaptor
11. Battery capacity indicator. Automatic shutdown for power saving
Standard accessories
one Adult finger SpO2 sensor
one TEMP skin probe
one AC charger
one PC software CD
one USB cable
Technical Specifications
1. General
Monitoring Parameters: SpO2,PR,PLETH,Pulse strength,TEMP
Signal sockets:SpO2 socket,PR socket,TEMP socket,USB socket(for charge battery and transmit data)
2. Display screen
Type: 160 ×128 dot matrix color OLED screen
Display area: 42mm×33mm
LED:Dual-color LED (red/green)
3. Functions
PLETH: The monitor can display PLETH waveform
Intelligent parameter monitoring screen: The monitor automatically selects the
parameter measurements to display according to the probes connected to the monitor.
Audio and visual alarm: The speaker sounds the alarm and the parameter’s measurement will become in red to flash on the screen. Also the same when sensor-off.
Prompting: Icons of battery capacity, pulse sound switch and alarm sound switch.
Power saving: The monitor will automatic shut down to save power. The time is settable.
Trend: Storage/Review trend data up to 3888 groups, data save time being set freely
Data storage: The saved data will never be lost even if the monitor is powered off.
Communication: Transmitting the patient’s trend to a PC for display, observation, saving and printing.
4. Electrical specifications: Working Voltage: D.C. 3.7V/3000mA;
AC power adaptor
Input: AC 100 V~240V, 50/60Hz, 5VA
Output: D.C. 5V
Internal battery
Type: D.C. 3.7V/3000mAH Li-ion rechargeable battery
Run Time: 15-hour continuous operation with a new, fully charged battery (environment temperature is 25°C)
Recharge time: 8 hours
5. Environment
Temperature
Operation: 0°C ~ 45 °C
Transportation and storage: -20°C ~ 60 °C
Humidity
Operation: 15% - 95 %( noncondensing)
Transportation and storage: 10% - 95 % (noncondensing)
Altitude
Operation: 86 KPa ~106 KPa
Transportation and storage: 50KPa~106 KPa
6. Parameter Specifications
SpO2
Patient: Adult, child
Range: 0% - 100%
Resolution: 1 %
Accuracy: 70% - 99%: ±2 %
0% - 69%: Unspecified
PR
Range: 0 bpm ~250bpm
Resolution: 1bpm
Accuracy: ±2bpm
TEMP
Channel: 1
Input: Body surface thermal-sensitive resistor temperature sensor
Range: 0°C~50°C
Resolution: 0.1°C
Accuracy: ±0.2°C
7. Product size: 115×60×28mm. NW: 195g