Portable patient monitor with touch screen

Portable patient monitor with touch screen

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
1000 Piece / Pieces per Month
Port:
Tianjin Beijing Shanghai
Payment Terms:
T/T Credit Card

Quick Details View All >

Type:
First-Aid Devices
Brand Name:
Longfian
Place of Origin:
Hebei, China
Model Number:
BD6000-05,07

Longfian Scitech Co., Ltd.

Business Type: Manufacturer,Trading Company
Baoding Hebei China
Main Products: Oxygen Concentrator ,Oxygen Analyzer ,Oxygen Cocktail Mixer

Product Details

Specifications

CE ISO approval
Portable for 24 hours measurement
ST segment
E-document instruction
ECG, NIBP, SPO2,Temperature, Respiration

  Portable patient monitor with touch screen

Specification:

1. General Specifications:

Size:154mm×128mm×40mm

Net Weight: 480g

Display Specification

Measurement Display: color LCD/touch screen

Power Supply Indicator: Dual-color LED (red/green)

Beat indicator: Dual-color LED (red/green)

2. Power Supply

AC Power Adaptor

Input: 100∼240VAC, 50/60Hz, 0.7A

Output: DC 4.2V, 800mA

Battery

Li-ion rechargeable battery, 3.7V, 5AHr

Operating Time: 5 hours with full battery capacity.

(Condition: 25, NIBP working period is 10 minutes)

Recharge Time: 10 hours.

3. Environment

Temperature

Working:0 ∼ 45 (°C)

Transport and Storage: -25∼ 85 (°C)

Humidity

Working:30% ∼85 %

Transport and Storage: 30% ∼95 % (no condensation)

4. Monitoring Parameter

ECG:

Input3- lead ECG cable, standard AAMI cable connector

Lead SelectionI,II,III

Gain Selection×1,×2,×4,×8

Sweep Speed: 12.5, 25, and 50 mm/s

Frequency Response: None filter: 0.05∼100Hz (-3dB), filter: 0.5∼40Hz (-3dB)

Calibration Signal: 1mV square wave 

Protection: Against electrosurgical interference and defibrillation

Heart Rate:

Measuring Range: 30∼250 bpm

Renew Time: 1 time per beat

Accuracy: ±1 bpm

Alarm Mode: Audible and visual alarm

SpO2: 

SpO2%

Measuring Range:0∼100%

Resolution:1 %

Accuracy:±2 %(70%∼99%), unspecified (0%∼69%)

Pulse Rate:

Measuring and Alarm Range:0∼250bpm

Resolution: 1bpm

Accuracy: ±1bpm

NIBP: 

Method: Oscillometric

Mode: Manual, Auto, STAT

Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 60 (min)

Measuring Period in STAT Mode: 5 min

Cuff Pressure Range:0∼300 (mmHg)

Pulse Rate Range:30∼250 (bpm)

Measurement Rage: Adult 30∼255mmHg, Pediatric 30∼160mmHg

Over-pressure Protection: Adult 300mmHg, Pediatric 220mmHg

Pressure Resolution : 1mmHg

The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those measured by trained medical personnel using cuff and stethoscope. The MEAN value measured using this device is equal to that measured using blood pressure measurement device. 

Temperature:

Input: Body surface thermal-sensitive resistor temperature sensor

Measuring Range: 0∼50

Accuracy: ±0.1

5. Storage and Review 

Maximum Data Quantity: 3888 groups

Maximum Trend Time: Continuous 129 hours

Contact Supplier

Ms. Jade Guo General Manager Chat Now
Telephone
86-137-22257756
Mobile
13722257756
Fax
86-312-5909515
Address
2F&3F, East Section, Building 12, Power valley pioneer park, NO.369 Huiyang street , 071051,Baoding, Hebei Province,China Baoding,Hebei

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Health & Medical > Medical Devices > Emergency & Clinics Apparatus
Categories
Hi~