240W Switching Power Supply 220V 12V 50A
Negotiable /Piece
Min.Order:1 Piece
Shenzhen Guandexin Technology Co., Ltd.
240W Switching Power Supply 220V 12V 50A
Product introduction
Full range of input, communication with the flow, over-voltage, short circuit protection function, since the cold heat dissipation, 100% full load test, low price, machine of high quality, reliable quality, 1 year of quality assurance
The input voltage range: 85-264 VAC, 47-63 Hz; 120-370 VDC
Impact current: cold start current
Dc voltage adjustable scope: 10% of the rated output voltage
Overload protection: 115% ~ 150% off current, automatic recovery
Over-voltage protection: output voltage of 115% 135%
Start up, keep time: 300 ms, 50 ms, 80 ms
Sex: input/output voltage between input and the shell: 1.5 KVAC output and the shell KVAC lasted a minute 0.5
Working temperature, humidity:-10 oC-+ 60 oC, 20%-90% RH
Safety standards: complying with CE standard
EMC standards: complying with CE standard
The power to be applicable to the industry, safety monitoring, machine, equipment, medical treatment, electrician, LED billboards, communication, and so on! Extensive use!
Max output wattage | 240W | |||
Input | Voltage | 90-132VAC or 180-260VAC (selectable by switch) | ||
Frequency(HZ | 50-60HZ | |||
Current(Full load) | 4.5A max (115VAC) 2.5A max (230VAC) | |||
Inrush Current | less 60AMAX (115VAC) /60Amax (230VAC) | |||
Leakage Current | less 3.5mA /240VAC | |||
Output | Voltage | 5VDC | 12VDC | 24VDC |
Voltage Accuracy | ±3% | ±2.5% | ±1.25% | |
Max. Current | 40 | 20 | 10 | |
Line Regulation | ±0.5% | ±0.5% | ±0.5% | |
Load Regulation) | ±1% | ±1% | ±1% | |
Minimum Load | 0% | 0% | 0% | |
Typical Efficiency | 80% | 84% | 89% | |
Adjustable extent of output voltage | 4.5-6.5 | 9-15VDC | 22-27 | |
Ripple Noise(max) | 150mV | 150mV | 150mV | |
Hold-up time | 20 ms min | |||
Switching Frequency | 30KHZ | |||
Protection | Over Load | 105-150% rated output power | ||
Protection type: Auto recovery | ||||
Short Circuit | Protection type: Auto recovery | |||
Electric Strength | Input-Output | 1500VAC | ||
Input-FG | 1500VAC | |||
Output-FG | 1500VAC |
Safety EMC
| Safety Standards | UL60950 EN60950 |
EMI | EN55011 class B EN55022 class B | |
EMS Immunity | EN55024 EN61000-6-2 | |
Harmonic Current | EN61000-3-2 |