ATOMIC ABSORPTION SPECTROPHOTOMETER

ATOMIC ABSORPTION SPECTROPHOTOMETER

USD $100 - $50,000 /Set

Min.Order:1 Set

Supply Ability:
100 Set / Sets per Month
Port:
China
Payment Terms:
T/T Credit Card

Quick Details View All >

Place of Origin:
Guangdong, China
Brand Name:
Dshing
Model Number:
DSH AAS6000
Power:
Electronic
Usage:
Other, Atomic Absorption Spectrometer

Dshing Instrument Co., Ltd.(Zhuhai)

Business Type: Trading Company
Zhuhai Guangdong China
Main Products: viscometer ,Inclinometer ,Geological Instrument ,Flash Point Tester ,proton magnetic detector

Product Details

Specifications

Single Beam Atomic Absorption Spectrometer
1.Stable
2.Table type
3.Easy operation
4. High accuracy

ATOMIC ABSORPTION SPECTROPHOTOMETER

 

DSH AAS6000 Single Beam Atomic Absorption Spectrometer

 

 

I. Instrument introduction

 

1. AAS6000 Series are Single Beam Atomic Absorption Spectrometers controlled and data processed by external computer and internal CPU chips. AAS6000 can be used to measure the concentration of macro, micro and trace metal elements and half-metal elements in various kinds of substances.


2. Atomic absorption spectrometry is a technique exploiting the fact that atoms at ground state may absorb the radiation of characteristic wavelength. As is known, the atoms are usually at ground state. For each element, the amount of energy required for an atom to transit from ground state to excited state is specific, and in general, is called characteristic wavelength. The Atomic absorption spectrometry typically makes use of hollow cathode lamp as the light source to emit the characteristic wavelength of a particular element. When the light passes through the atomic vapor, it is absorbed by the vapor. The concentration of the element can then be determined through the calculation of the absorption rate.


3. AAS6000 is provided with three reading methods Continuum, Retention and Peak Height for measuring absorbency, density and emission intensity. It has three signal modes: Atomic Absorption, Background Absorption and Background Correction Absorption, The reading time ranges from 0.5 s to 99s. AAS6000 include 8 computer controllable hollow cathode lamp holders. All working conditions of the instrument such as lamp number, lamp current, negative high voltage, working wavelength, slit, burner location, ignition/extinction and adjustment of burning ratio can be set by keyboard input. The functions of the instrument include automatic gain/ automatic zero, background correction, automatic energy balance, automatic peak location/wavelength scan, and automatic peak location on basis of the retrieval of peak values. All the readings, measurement results, calibration curves and operation conditions can be saved or printed out.

 

 

II. Performance characteristics

1. C2H2 monitoring; flame measurement; all reflective, aberration corrected
2. Fully automated instrument, total automatic operation
3. 8 element lamps, time saved for changing lamps
4. Gas path safety measures, safer operation
5. USB interface allows you to operate the instrument conveniently and rapidly.
6. 230nm grating blazed wavelength, multiplied sensitivity in the Ultraviolet zone
7. 1800g /mm grating grooves, maximized resolution
8. Run in Windows operating system, the powerful software enables automatic qualitative and quantitative analysis. Automatic report generation in Excel format allows you to operate the instrument and process the data easily. You operation doest get any easier with our graphical interfaces.

 

 

III. Technical specifications

1. Model: DSH AAS6000
2. Optical system: all-reflective single-beam CT optical path
3. Focal length of monochromator: 350mm, oil/water proof air compressor
4. Blazed wavelength of gratings: 230nm
5. Number of grating grooves: 1800g /mm
6. Wavelength range:  190nm-900nm
7. Wavelength accuracy:   ±0.1nm
8. Wavelength repeatability: ±0.1nm
9. Spectrum bandwidth: 0.1nm, 0.2nm, 0.4nm, 0.7nm, 1.4nm
10. Noise: 0.005 Abs(static); 0.006 Abs(Dynamic)
11. Baseline drift: 0.003 Abs/0.5h; best performance
12. Background correction: D2 lamp + self reversal
13. Number of the lamps: 8
14. Number of preload lamps: software controlled, ≤8
15. Gas path safety measures: yes
16. Atomizer: flame atomizer
17. Automation: lamp / slit / wavelength / gas path / ignition / burner / safety measures / C2H2 monitoring

 

 

IV. Standard configurations

1. AAS6000 mainframe

2. Oil-free air compressor with lower noise

3. Special pressure gauge and peripheral accessories

4. Hollow cathode lamp

5. PC (brand computer, P4, LCD) 1 set

6. Printer (Canon, colorful ink-jet printer) 1 set

7. Wooden case packing and transportation

 

 

V. Application fields

1. Geology, minerals, metallurgy, steel, non-ferrous metals
2. Environmental analyses: air, water quality, soil and solid wastes
3. Petrochemical engineering, crude oil and related products, light industrial products,
4. Food, biomedicine and health products
5. Building materials (glass, ceramic, paints, etc)
6. Steel and non-ferrous metals analysis
7. Soil and solid wastes analysis
8. Biomedicine and health products analysis
9. Food analysis

 

 

More products, pls visit our 

 

 

Hot-line: 0086-13286053267  

 

Miss Angel is at your service in 24 hours. 

 

Skype ID: dshingsales5

 

 

 

Contact Supplier

Mr. Lionel Lee Chat Now
Telephone
86-756-8305811
Mobile
13286053265
Fax
86-756-8305812
Address
Room 1401, Unit 1, Bldg. 2, No. 133, Maofeng Road, Xiangzhou Dist., Zhuhai,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Testing Equipment
Categories
Hi~