55kw 75kw 90Kw 7-13 bar Stationary silent screw Air Compressor
Negotiable /Set
Min.Order:1 Set
Dream(Shanghai) Compressor Co., Ltd.
55kw 75kw 90Kw 7-13 bar Stationary silent screw Air Compressor
High efficient air end
1. Screw air end is the core of screw air compressor, its performance directly influence the economy and use costs of the whole machine.
2. Dream compressor adopts the air end original from Europe. Advanced patent SAP shape of screw gear, the most superior screw line speed and compression efficiency, decrease the shake of the whole machine to the fullest extent, and prolong the life of moving parts effectively.
3. The compressor is matched with high-precision SKF bearing. The precise and even bite clearance ensures leak tightness, making sure the compressor become less power dissipation and lower energy consumption under the same working conditions, and achieve goals as following: a. Large air capacity, b. Higher efficiency, c .More stability and reliable, d. Longer service life.
High quality air end and bearing
High quality air end and bearing contribute to high stability of compressor under changeable conditions. Make the compressor adapts to the changeable of loading and prolong the service life of rotors: a. Low running speed decreases the abrasion of bearing, b .Low running temperature letdown the load of bearing. c. High precision bearing prolongs the service life.
Air end and electric Motor Being Permanently Centered
1. DM series compressor combines the electric motor, gear case and air end. Such design makes the air end and electric motor be permanently centered.
2. High efficiency and full closed electric motor (IP54).
Intake air filter
1. High efficiency imported filter,
2. Dust removal effect of 99.9%,
3. Ensure that the compressor host effective dust,
4. The extension of air system of life.
Intake valve
1. According to the system capacity requirement, automatically adjust the volume, ensure smooth operation of equipment and reduce the operating cost, energy saving,
2.Automatic loading/unloading is reliable and effective, with no-load starting, motor overload shutdown protection, no-load long automatically shut down to conserve energy, parking time delay protection, reverse phase missing protection, too high exhaust temperature shutdown protection,
3. The vulnerability of small-less maintenance work,
4. Large size, small pressure drop, inspiratory capacity.
High efficient oil filters
Imported seeking rotary filter, the effect is 20% higher than conventional filter, filtration precision is 9 micron, better protection to the air end to get a longer life.
Minimum pressure valve
Original imported minimum pressure valve, and reliable to ensure the minimum pressure required during the starting and oil circulation in unloading operation.
Level 3 oil and gas separation system
The three oil gas separation system (centrifugal, gravity, fine separation) built-in core of efficient oil and gas separator, to ensure that the compressed air oil consent of less than 3 ppm.
5.5-30KW:
Model | DM-5A | DM-7A | DM-11A | DM-15A | DM-18A | DM-22A | DM-22AZ | DM-30A | |
Air discharge/Pressure discharge (m3/min,Mpa) | 0.85/0.7 | 1.2/0.7 | 1.7/0.7 | 2.4/0.7 | 3.1/0.7 | 3.8/0.7 | 3.8/0.7 | 5.2/0.7 | |
0.78/0.8 | 1.1/0.8 | 1.6/0.8 | 2.2/0.8 | 2.9/0.8 | 3.5/0.8 | 3.5/0.8 | 5.0/0.8 | ||
0.65/1.0 | 0.95/1.0 | 1.4/1.0 | 2.0/1.0 | 2.7/1.0 | 3.2/1.0 | - | 4.3/1.0 | ||
0.5/1.3 | 0.8/1.3 | 1.2/1.3 | 1.7/1.3 | 2.2/1.3 | 2.9/1.3 | - | 3.7/1.3 | ||
Electromotor | Power (Kw) | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 22 | 30 |
Horsepower (HP) | 7.5 | 10 | 15 | 20 | 25 | 30 | 30 | 40 | |
Noise(dB) | 65±2 | 66±2 | 68±2 | 68±2 | 69±2 | 69±2 | 69±2 | 69±2 | |
Air outlet pipe diameter | G3/4 | G3/4 | G3/4 | G3/4 | G11/4 | G11/4 | G11/4 | G11/4 | |
Unit weight(Kg) | 200 | 240 | 400 | 410 | 590 | 630 | 620 | 680 | |
Dimensions (mm) | L | 800 | 800 | 850 | 1000 | 1000 | 1050 | 1350 | 1050 |
W | 800 | 800 | 800 | 900 | 900 | 1050 | 800 | 1150 | |
H | 900 | 900 | 900 | 1150 | 1150 | 1300 | 1150 | 1300 | |
Cooling air volume (m3/min) | 23 | 23 | 91 | 91 | 100 | 100 | 100 | 100 |
37-90KW:
Model Model | DM-37A | DM-37AZ | DM-45A | DM-55A | DM-55AZ | DM-75A | DM-75AZ | DM-90A | DM-90AZ | |
Air discharge/Pressure discharge (m3/min,Mpa) | 6.4/0.7 | 6.4/0.7 | 8.0/0.7 | 10.5/0.7 | 10.5/0.7 | 13.6/0.7 | 13.6/0.7 | 16.3/0.7 | 16.3/0.7 | |
6.1/0.8 | 6.1/0.8 | 7.7/0.8 | 9.8/0.8 | 9.8/0.8 | 13.3/0.8 | 13.3/0.8 | 16.0/0.8 | 16.0/0.8 | ||
5.7/1.0 | - | 7.0/1.0 | 8.7/1.0 | - | 11.6/1.0 | - | 14.6/1.0 | 14.6/1.0 | ||
5.1/1.3 | - | 5.8/1.3 | 7.5/1.3 | - | 9.8/1.3 | - | 12.3/1.3 | 12.3/1.3 | ||
Electromotor | Power (Kw) | 37 | 37 | 45 | 55 | 55 | 75 | 75 | 90 | 90 |
Horsepower (HP) | 50 | 50 | 60 | 75 | 75 | 100 | 100 | 125 | 125 | |
Noise(dB) | 70±2 | 70±2 | 72±2 | 73±2 | 73±2 | 75±2 | 75±2 | 75±2 | 75±2 | |
Air outlet pipe diameter | G11/2 | G11/2 | G11/2 | G2 | G2 | G2 | G2 | G2 | G2 | |
Unit weight(Kg) | 840 | 840 | 860 | 1600 | 1700 | 1750 | 1800 | 2000 | 1980 | |
Dimensions (mm) | L | 1050 | 1600 | 1200 | 1200 | 1800 | 1500 | 1800 | 1800 | 2150 |
W | 1050 | 1000 | 1200 | 1200 | 1200 | 1240 | 1200 | 1400 | 1300 | |
H | 1300 | 1400 | 1500 | 1500 | 1400 | 1600 | 1400 | 1600 | 1550 | |
Cooling air volume(m3/min) | 180 | 180 | 191 | 320 | 320 | 330 | 330 | 400 | 400 | |
Water-cooled cooling | Water volume(T/H) | 2 | 2 | 3 | 5 | 5 | 5 | 7 | 7 | 7 |
Air volume(m3/min) | 23 | 23 | 23 | 23 | 23 | 23 | 23 | 23 | 23 |
110-400KW:
Model Model | DM-110A | DM-132A | DM-160A | DM-185A | DM-220A | DM-250A | DM-315A | DM-350A | DM-400A | |
Air discharge/Pressure discharge (m3/min,Mpa) | 20.8/0.7 | 24.8/0.7 | 28.5/0.7 | 32.5/0.7 | 38.6/0.7 | 43.9/0.7 | 51.2/0.7 | 64.0/0.7 | 74.0/0.7 | |
20.6/0.8 | 24.0/0.8 | 27.0/0.8 | 30.2/0.8 | 36.4/0.8 | 42.5/0.8 | 50.2/0.8 | 62.0/0.8 | 72.0/0.8 | ||
17.0/1.0 | 20.6/1.0 | 23.2/1.0 | 27.0/1.0 | 33.1/1.0 | 38.8/1.0 | 44.5/1.0 | 57.6/1.0 | 62/1.0 | ||
14.2/1.3 | 16.5/1.3 | 19.7/1.3 | 22.5/1.3 | 30.5/1.3 | 34.6/1.3 | 39.5/1.3 | 49.0/1.3 | 56.5/1.3 | ||
Electromotor | Power (Kw) | 110 | 132 | 160 | 185 | 220 | 250 | 315 | 350 | 400 |
Horsepower (HP) | 150 | 180 | 220 | 250 | 300 | 340 | 400 | 480 | 540 | |
Noise(dB) | 75±2 | 75±2 | 75±2 | 78±2 | 78±2 | 78±2 | 80±2 | 82±2 | 83±2 | |
Air outlet pipe diameter | DN65 | DN65 | DN80 | DN80 | DN100 | DN100 | DN125 | DN125 | DN150 | |
Unit weight(Kg) | 3130 | 3330 | 3500 | 3700 | 4800 | 5200 | 7300 | 7900 | 8400 | |
Dimensions (mm) | L | 2450 | 2450 | 2650 | 2650 | 2800 | 2800 | 4200 | 4200 | 4200 |
W | 1600 | 1600 | 1600 | 1600 | 1950 | 1950 | 2200 | 2200 | 2200 | |
H | 1700 | 1700 | 1800 | 1800 | 2000 | 2000 | 2350 | 2350 | 2350 | |
Cooling air volume(m3/min) | 450 | 450 | 500 | 600 | 900 | 900 | -- | -- | -- | |
Water-cooled cooling | Water volume(T/H) | 10 | 10 | 10 | 12 | 20 | 20 | 25 | 30 | 35 |
Air volume(m3/min) | 100 | 100 | 100 | 100 | 145 | 145 | 200 | 200 | 250 |
Remark:1Mpa=10bar=145psi,1m3/min=35.3cfm
Website: /