SC808 Flow Totalizer
Negotiable /Piece
Min.Order:100 Pieces
Qingdao SICO Electrical Equipment Co., Ltd.
With complete temperature and pressure compensation function, can realize general gas, saturated steam, superheated steam etc
Product description:
With complete temperature and pressure compensation function, can realize general gas, saturated steam, superheated steam and the liquid temperature and pressure compensation operations.
Flow totalizer could cumulative calculation for material quality, volume, length, and accumulation in batch control!
When it use as batch control, the instrument has a separate four control cumulative and 12 total cumulative.
Programmable input specifications, flow rate input signal can be programmable to frequency, 1-5V, 0-5V, 0-10mA, 4-20mA, can also be customized special input specifications. The temperature signal can programmable TO Pt100 resistor thermometer, K, E, J-type thermocouples, or standard current signal; the pressure signal as a standard voltage or current signal.
Programmable function for instantaneous flow rate, temperature and pressure of the upper and lower limit alarm functions, and have the transmission output, communications, 24V/12V voltage output to a variety of functions.
Advanced computational methods to ensure that the frequency signal, even at very low frequencies there is sufficient flow computation accuracy
Optional communication module to connect the AI series true color man-machine interface touch screen / split paperless recorder
Panel size: A,A2,A6,B,B6,C,C3,E,E5,F
Measurement accuracy | 0.2%FS ± 0.1°C |
Resolution | 0.1°C |
Temperature drift | ≤0.01%FS /°C (typical value is 50ppm/°C) |
Response time | ≤0.3s ( when digital filter parameter dL=0) |
Input | Linear voltage: 0~5V, 1~5V, 0~1V, 0~100mV, 0~60mV, 0~20mV, etc.; 0~10V if module I31 is installed on MIO socket. |
Linear current (external connect to precise shunt resist or install I4 module on MIO): 0~20mA, 4~20mA, etc. | |
Linear resistance : 0~80ohm, 0~400ohm. | |
Output AUX | Linear current output: 0~20mA, 4~20mA (The output voltage of X module ≥10.5V; and that of X3 module ≥10.5V.) |
General specifications | Voltage: support AC85-265V,50/60Hz or DC24V. |
Power consumption: ≤5W or ≤0.8W if no alarm and output | |
Isolation withstanding voltage : between power, relay contact or signal terminal ≥2300VDC; between isolated electroweak terminals ≥600VDC | |
Electromagnetic compatibility (EMC) : ±4KV/5KHz according to IEC61000-4-4; 4KV according to IEC61000-4-5. | |
Operating Ambient : temperature -10~60°C; humidity ≤90%RH |