Insulation Piercing Connector/SC-JCF1-150/150 insulation piercing connector
Negotiable /Piece
Min.Order:500 Pieces
Qingdao SICO Electrical Equipment Co., Ltd.
Insulation piercing connectors,Apply in Tee secondary connection for power cable in constructions electric system, LV overhead line, LV house cables, Street lighting system, common tap connection, underground power grid and tunnel illumination system, etc..
SC-JCF1-150/150 insulation piercing connectors
Application
Apply in Tee secondary connection for power cable in constructions electric system, LV overhead line, LV house cables, Street lighting system, common tap connection, underground power grid and tunnel illumination system, etc..
The installation of insulation piercing conne-ctors is can live work and power-cut work.
Technical data
Type | Main line section (mm2) | Branch section (mm2) | Nominal current (A) | Bolt | Piercing depth (mm) | |||
mm2 | AWG | mm2 | AWG | Quantity | H(Nm) | |||
SC-JCF1-150/150 | 35-150 | 2-300 | 35-150 | 2-300 | 504 | 1 x M8 | H13(18Nm) | 1.5-2.5 |
If you need special mold of insulation piercing connector which is not list in our products-line, please send the drawing to us for custom production, thanks.
Structure picture
The excellent performances of Insulation Piercing connectors for electric cables
1.Ease of installation
There is no cable stripping required for install it to connection and the joint is completely insulation.
No power cut need for installation and the site is anywhere.
The installation is easy and reliable. Only need common spanner to wrench the torque screw and it can live work.
2.Safe use
The joint has good resistance to distortion, quake, wet, electroc-hemical corrosion and aging, need no maintenance. Has been used successfully for 30 years.In China they are widely used by some contractors, under the extreme storm in 2008, there had no fault of power off due to our SMS brand insulation piercing clamps, also the operating cable did not drop out of our existing clamps resulting from heavy covered ice. These are to prove that the quality of our device are very reliable again.
3.Save cost
The installation space is small and save the space and const-ruction cost.
There is no terminal box, jun-ction box and circle cable req-uired in IPC installation and save many cost.
The cost of cable and IPC is low than other electric supply system.
If you are interested in our company and products, please dont hesitate to contact Ms.Amy Yin
yinamy9@gmail [dot]com AND sikeqd@126 [dot] com