High Precision MEMS Inclinometer Sensor With 4-20mA Stable Data Output
Negotiable /Piece
Min.Order:1 Piece
Shenzhen Rion Technology Co., Ltd.
High Precision MEMS Inclinometer Sensor With 4-20mA Stable Data Output
General Description
HCA528T inclinometer use the dynamic zero test compensation technology to ensure product Quick Launch, high resolution ,stable data, good capacity to bear shock & vibration, built-in anti-RF, adopts anti-electromagnetic interference circuit to ensure that the output signal to a higher anti-interference ,in addition to this product is better than the similar market product on software technical data, on the reliability and stability the product is also using the high-end application-level MCU,three-proofing PCB board, imported cable, wide temperature shielded metal enclosure and other measures to improve product industrial level,to ensure the product can be long-term & safetyextraordinary operation in harsh environments.
Feature
Application:
Technical Data :
Measuring range |
| ±10 | ±30 | ±60 | ±90 | ° |
Measuring axis |
| X,Y | X,Y | X,Y | X,Y |
|
Zero output | 0°Output | 12 | 12 | 12 | 12 | mA |
Resolution |
| 0.001 | 0.001 | 0.001 | 0.001 | ° |
Absolute accuracy |
| 0.005 | 0.01 | 0.02 | 0.05 | ° |
Long term stability |
| 0.01 | 0.02 | 0.05 | 0.08 |
|
Zero temperature coefficient | -40~85° | ±0.002 | ±0.002 | ±0.002 | ±0.002 | °/℃ |
Sensitivity temperature coefficient | -40~85° | ≤50 | ≤50 | ≤50 | ≤100 | ppm/℃ |
Power on time |
| 0.5 | 0.5 | 0.5 | 0.5 | S |
Response time |
| 0.05 | 0.05 | 0.05 | 0.05 | s |
Response frequency response frequence |
| 1~20 | 1~20 | 1~20 | 1~20 | Hz |
Electromagnetic compatibility | According to EN61000 and GBT17626 | |||||
MTBF | ≥50000 hours/times | |||||
Insulation Resistance | ≥100M | |||||
Shockproof | 100g@11ms,3Times/Axis(half sinusoid) | |||||
Anti-vibration | 10grms,10~1000Hz | |||||
Protection glass | IP67 | |||||
Cables | Standard 1M length,wearproof,wide temperature, Shielded cables4*0.4mm2 air-plug connector | |||||
Weight | 150g(without cable) |
* This Technical data only list ± 10 °, ± 30 °, ± 60 °, + 90 ° series for reference, other measuring range please refer to the adjacent parameters
Our Company & Workshop View :
Certificates & Test Reports :