Z-wave Motion Sensor
USD $19 - $33 /Piece
Min.Order:1 Piece
Dongguan NIE Technology Co., Ltd.
Introduction
This sensor is a Z-Wave enabled device (interoperable, two-way RF mesh networking technology) and is fully compatible with any Z-Wave enabled network. Every mains powered Z-Wave enabled device acts as a signal repeater and multiple devices result in more possible transmission routes which helps eliminate “RF dead-spots”.
Technical data
*Operation Range: 8m
*360/ 110 of view,1200 Horizontal Angle Coverage
*Low battery detection
*Tamper Switch
*Range: 30m line of sight
*Operating temp: -15oC~40oC
*Working Voltage: 3V
* Battery: CR123A *1pc
*Dimensions: 91.5*61.5*48MM
*Frequency:868.4MHz/865.2MHz/869.2MHz/908.4MHz/921.4MHz
Installation
1. Release cover tab to open the cover.
2. Insert a CR123A battery into the battery compartment, and LED will start to flash slowly, which means the sensor has not yet been “inclusion”.
3. Close the cover back to sensor.
4. For “Add” in (adding to): Put the Z-Wave Interface Controller into “Add” mode, and following its instruction to add the ZW112 to your controller. To get in the “Add” mode, the distance between sensor and controller is suggested to be in one meter. Press the learn switch of ZW112 once. The LED on the ZW112 should stop flashing, if not, please try again. For “Remove” from (removing from) a network: Put the Z-Wave Interface Controller into “Remove” mode, and following its instruction to delete the ZW112 to your controller. Press the learn switch of ZW112 once to be excluded. The LED on the ZW112 should start to flash. For “Group”: removing the cover of the ZW112 to get into “Awake” mode, then put the Z-Wave Interface Controller into “Group”, and following its instruction to associate the ZW112 with other device. Close the cover back after “Group” done, afterward the ZW112 will get into “Sleep” mode for power saving. Support one association group (5 nodes). Note: ”Awake” mode: it is to leave the “Sleep” mode by removing the cover of ZW112, to allow the Z-Wave Interface Controller to do “Group.
5. Using gum wall plug & screws to mount ZW112 at 2 meters above surface. To enhance proper operation, place ZW112 on the angle which can detect the room widely. The solid area means the detector’s coverage range.
Safety and maintenance instruction
- Make sure that all electric connections and connection cables meet the pertaining regulations and are in conformity with the operating instruction.
- Do not overload electrical outlets or extension cords, fire or electric shocks can be the result.
- Please contact an expert in case you have any doubts about the mode of operation, the safety or connecting the appliances.
- Keep all parts away from young children’s reach.
- Do not store this item on wet, very cold or warm places, this can damage the electronic circuit boards.
- Avoid dropping or shocks, this can damage the electronic boards.
- Never replace damaged power cables yourself! In such case, remove them from the net and take the devices to a workshop.
- Wireless system are subject to interference from cordless phones, microwaves, and other wireless devices during installation and operation.
Maintenance
The devices are maintenance-free, so never open them. The guarantee becomes void when you open the appliance. Only clean the outside of the devices with a soft, dry cloth or a brush. Prior to cleaning, remove the devices from all voltage sources.
NOTE
Do not use any carboxylic cleaning agents or petrol, alcohol or similar. These will attack the surface of devices. Besides, the vapors are hazardous to your health and explosive. Do not use any sharp edged tools, screw drivers, metal brushes or similar for cleaning.
Warranty 1 year