Sino-Telecom Long Distance ADSL Repeater, ADSL Loop Extender
Sino-Telecom Long Distance ADSL Repeater, ADSL Loop Extender
Sino-Telecom Long Distance ADSL Repeater, ADSL Loop Extender
Sino-Telecom Long Distance ADSL Repeater, ADSL Loop Extender

Sino-Telecom Long Distance ADSL Repeater, ADSL Loop Extender

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
1000 Piece / Pieces per Month
Port:
Shanghai Port
Payment Terms:
T/T D/P D/A Credit Card

Quick Details View All >

Place of Origin:
Shanghai, China
Brand Name:
Sino-Telecom
Model Number:
AER800-1P

Shanghai Sino-Telecom Technology Co., Ltd.

Business Type: Manufacturer,Trading Company
Shanghai China
Main Products: IP DSLAM ,wdm system

Product Details

Overview

ADSL technology has great advantages in terms of bandwidth and performance and is the major broadband access technology. However, the longer the distance between CO and CPE, the lower the speed ADSL can achieve.
AER800-1P can extend the coverage of single ADSL line and resolve the above issue very well. It will provide systems with higher performance-to-cost ratio for telecom operators, improve the equipment utilization rate, optimize the network and boost the ability to compete. Along with protection of current investment, this ADSL repeater can have more broadband access subscribers and value-added services accommodated by extending coverage of existing ADSL network. As the result, it will bring back huge return.

 

 

Function and Features

ADSL Repeater

ADSL Repeater Power Supply 

 
Technical Specifications
 

Table 1 -- Technical Specifications of AER800-1P

Input VoltagePowered by ADSL Repeater Power Supply
Power Consumption1.3W/line
Weight<1.5Kg
Temperature Relative Humidity-40℃~60℃
5%~95% (Non-condensing)

 

 

Table 2 -- Technical Specifications of AEC-B1P

If AER800-1P is deployed with AEC-B4P, please refer to user manual of AEC-B4P)

Outside Dimension118mm×34mm×34mm
Weight<0.5Kg
Temperature-35℃~50℃
Relative Humidity5%~95% (Non-condensing)
Input VoltageAC 100~240V or DC -48V (-36V~-72V)
Output VoltageDC 116V
Max. Output Power10W
Max. Output Current100mA

 

 


Physical Structure 

 

AER800-1P

AEC-B1P

(If AER800-1P is deployed with AEC-B4P, please refer to user manual of AEC-B4P.)

Fig. 1 -- AEC-B1P Connector Wiring Diagram


Installation

Equipment Installation Diagram

 Sino-Telecom Long Distance ADSL Repeater, ADSL Loop Extender

 

Fig. 2 -- AER800-1P Network Application Diagram
L1: The signal wire pair connecting ADSL repeater to CO equipment.
L2: The signal wire pair connecting ADSL repeater to CPE equipment.
L3: The power wire pair connecting ADSL repeater to power supply.

 

Installation Environment

Before installation, the DC 48V or AC110-240V power supply and reliable ground connection should be assured. The customer should order the corresponding type of power supply according to the available power source.

 

Installation Procedures

The recommended installation conditions are as follows. Total line loop resistance is about 800ohm to 1600ohm; loop resistance between repeater and CO is about 450ohm to 1260ohm; loop resistance between repeater and CPE is about 200ohm to 900ohm.

 

 

Open the package and take out the equipment, check items according to the package list. Visually inspect it for signs of damage.

 

 

The power supply cable here is the normal twist-pair phone line.

 

The power supply cable here is the normal twist-pair phone line.
When remote supply is desired, pick the twist-pair available for power supply usage first (L3 as shown in Fig. 2). The supply voltage from wiring box will pass through wiring rack and cable, finally goes into ADSL repeater. When local power supply is desired, the supply voltage from wiring box will go through twist-pair and into the ADSL repeater directly.

 

 

Connect the equipment's ground to CO's grounding terminal directly.

 

 

The supplied accessories include power cord for AC 110-240V or DC 48V. Connect it to the AC110-240V or DC 48V power source with good connection. To easy the installation, DC power source connection is not polarized.

 

Attention: ADSL repeater's power supply should NOT be turned on until the repeater installation is finished.

 

 

Equipment is installed in the cabinet box. ADSL repeater can be placed in the box if there is inner room available. Or the repeater can be mounted in the box through supplied mount-ing brackets.

 

Attention: Copper-core wire with no less than 1.5mm2 section area is required as ground wire. One end of the wire should connect to repeater's ground terminal. The other end of the wire should connect to a good ground-ing point.

 

 

I. Identify and separate the signal twist-pair and power sup-ply twist-pair.

 

II. Remove about 10mm insulation coat of the twist-pair for first channel CPE side, connect to the "white/green" pair of the ADSL .

 

III. Remove about 10mm insulation coat of the twist-pair for first channel CO side, connect to the "white/orange" pair of the repeater.

 

IV. Remove about 10mm insulation coat of the twist-pair for power supply from CO, connect to the "white/blue" pair of the ADSL repeater.

 

Attention:

 

a) "A" and "B" represent A and B wire of the twist-pair. No polarity, pls do all the above for wire A and wire B sepa-rately .
b) Before power up the system, please make sure all the con-nections are correct.
c) When the power supply wire is active, do NOT operate the A and B wire of the supply pair simultaneously. The A wire and B wire should be isolated.

 

 

After confirming that all the twist-pair cables are connected correctly and enclosure is securely installed, power up the system. The ADSL repeater will work in 20 seconds after power is supplied steadily.

 

Troubleshooting 

Table 3 AEC-B1P Troubleshooting  

(If AER800-1P is deployed with AEC-B4P, Please refer to user manual of AEC-B4P) 

Problem DescriptionPossible ReasonSuggested Resolution
Equipment does not workPower cord is notCheck power code connection.
 after power-up. Status LED is OFF. correctly connected.
Power indicator flashes.Power output circuitry fails.Check whether the
 connection is shorted.
Output is OK but ADSL repeater  does not work.Power output cable connection Correct the power output
error or short connection or check cable

 

Table 4 AER800-1P Troubleshooting

Problem DescriptionPossible ReasonSuggested Resolution
Equipment does not work after Power supply cable is notCheck power supply 
power-up. Status LED is OFF. connected properly.and power cable.
No connectionStatus LED is always on.Cable to CO or CPE is notCorrect the cable connection.
 connected properly.
Status LED flashes.Cable on repeater is not 
connected properly.

 

 

Contact Supplier

Mr. Tiger Xie Chat Now
Telephone
086-021-67755366
Address
6F,Building 2,Lane 115,No 1276,Nanle Rd Songjiang District,Shanghai,P.R.China Shanghai

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Telecommunications > Communication Equipment > Fiber Optic Equipment
Categories
Hi~