Low Cost Electromagnetic DN15-DN25 Mechanical / Ultrasonic % Flow Meter Heat Meter
Low Cost Electromagnetic DN15-DN25 Mechanical / Ultrasonic % Flow Meter Heat Meter

Low Cost Electromagnetic DN15-DN25 Mechanical / Ultrasonic % Flow Meter Heat Meter

USD $33.35 - $43.35 /Piece

Min.Order:100 Pieces

Supply Ability:
70000 Unit / Units per Month
Port:
Shanghai or Ningbo
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal

Quick Details View All >

Place of Origin:
Zhejiang, China
Brand Name:
Mseed
Model Number:
DN15

Wenzhou Mseed Electric Co., Ltd.

Business Type: Trading Company
Wenzhou Zhejiang China
Main Products: energy meter ,circuit breaker ,switching power supple ,water meter ,heat meter

Product Details

Product Details
Product Introduction

Quick details.

Place of Origin: Zhejiang, China (Mainland)
Brand Name: Mseed
Model Number:DN15
Input Voltage: 220/230V
Operating Temperature: 5℃~55℃
Output Frequency: 50 or 60Hz

Temperature sensor length: 1.5m

IP class: IP 68

Battery working life: >6 years

Features

The installation requirements of the heat meter

1.Before installation, check the pipelines in the cleansing system thoroughly and remove silk,
hemp ,sand ,gravel and any other masses to avoid any flow hindrance.

2.The flow meter should be installed in horizontal level, with the display window
facing upward.

3.The diameter of the front and the back pipes should fit the flow meter

4.10DN straight pipeline and 5DN straight line should be saved (DN is what we call the diameter of the heat meter)

5.Must use the gasket and connecting pipeline specially designed and manufactured by
our company.

6. The sewage filter and the valve should be fixed at both ends of the flow meter for the
convenience of filth removing, maintaining and replacing.

7. After the installation ,seal between the connecting bolt of the capsule and the heat meter, between the temperature measuring ball valve and the platinum resistor.

8.Best water inflow and outflow pipeline options for easy fixing.

Parameters
Nominal Diameter
15
20
25
32
40
Dimension
L
110
130
130
200
200
W
87
87
87
85
85
H
101
101
125
125
130
Max flow (m3/h)
3
5
7
12
20
Norm flow(m3/h)
1.5
2.5
3.5
6
10
Min flow(m3/h)
0.03
0.05
0.07
0.12
0.2
Max flow reading
999999.99(m3)
Max heat reading
99999999(KW·h)
Power supply
3.6VDC
Battery life
>6 years ( Lithium battery)
Accuracy class
Class 2
Communication mode
Infrared interface , M-BUS/RS485
Press loss
≤ 0.025 Mpa ( under normal flow)
IP class
IP 68
Temperature range
(0--95) ℃
Temperature difference
(3--60) k
Starting temperature difference
0.01k
Temperature sensor
Pt 1000
Ambient temperature
+5℃ -- +55℃
Ambient level
Level A
Installation
Horizontal/ vertical installation
Monitor
8 digits
Length of temperature sensor
1.5m
Working current
45uA
Data storage
Store historical data up to last 24 months
Applications

The installation requirements of the heat meter
Before installation, check the pipelines in the cleansing system thoroughly and remove silk, hemp ,sand ,gravel and any other masses to avoid any flow hindrance.
1.The flow meter should be installed in horizontal level, with the display window facing upward.

2.The water flows in the direction accordance with the arrow mark

3.The diameter of the front and the back pipes should fit the flow meter

4.10DN straight pipeline and 5DN straight line should be saved (DN is what we call the diameter of the heat meter)

5.Must use the gasket and connecting pipeline specially designed and manufactured by our company.

6.The sewage filter and the valve should be fixed at both ends of the flow meter for the convenience of filth removing, maintaining and replacing.

7.After the installation ,seal between the connecting bolt of the capsule and the heat meter, between the temperature measuring ball valve and the platinum resistor.

8.Best water inflow and outflow pipeline options for easy fixing.


The installation of temperature sensor
One temperature sensor with red tag is to be installed inside the heat measuring meter, the other sensor with blue tag is to be built inside the temperature measuring ball valve.

The lead wire of the temperature sensor is not allowed to be lengthen, shorten or changed casually.



Performance
Household mechanical heat meter bears the features of high accuracy, steady operation, long using life, no subjecting to inferior water and low maintaining cost .It can be widely used in concentrated or regional heat supply system or separate household measuring in central air condition system

Dimension
Packing Details

Being packed according to the international standard is to guarantee safe delivery during the transportation. 

Why Choose Us

•Professional manufacturer with internationally standard production lines and a devoted technical team.

•Strict test procedure with advanced test equipment

•Responsive and responsible service team.

•Door to door service when needed.

•Helpful and enthusiastic in developing the buyers’ business. 


•Treat your career as our career. 

Certifications:

Welcome to contact us:

For sales or information inquiry, please contact us in the following ways:
Mob:+86 13588948320
Tel: +86-577-55770369
Skype: angelwu7777(+86-13588948320)
Trade messenger: Angel Wu
Website: http://mseed.en.china.cn
                 

Contact Supplier

Mr. Justin Bao Sales Manager Chat Now
Telephone
0086-577-55770369
Mobile
008618017341393
Fax
0086-577-55770369
Address
#110 Xinguang Industrial Zone Zhejiang

You May Like