DIN Railed DC Gigabit One Port POE Injector

DIN Railed DC Gigabit One Port POE Injector

Negotiable /Piece

Min.Order:5 Pieces

Supply Ability:
1000 Piece / Pieces per Month
Port:
Taiwan

Quick Details View All >

Place of Origin:
Taiwan
Brand Name:
MITS
Model Number:
DIN-POE-3AD/3ARD/3BD

MITS COMPONENT & SYSTEM CORP.

Business Type: Manufacturer,Buying Office,Distributor/Wholesaler
Main Products: Power Over Ethernet ,Ethernet Bridge ,Wireless Outdoor Bridge ,DC to AC Inverter ,Handheld Tester

Product Details

 

Transform the 36V~72V DC power to DC 56V. Injector the DC power through CAT-5 cable into remote Gigabit Ethernet devices that require high power after IEEE 802.3at detection. The PoEInjector supports industrial grade of operating temperature to meet the industrial application’s need.

 

We have 3 different models to deliver the DC power thru CAT-5 cable pins (#).

  a. Mode A (DIN-POE-3AD) : #1/2 (-) & #3/6 (+)

  b. Mode AR (DIN-POE-3ARD) : #1/2 (+) & #3/6 (-)

  c. Mode B (DIN-POE-3BD) : #4/5 (+) & #7/8 (-)

 

 

 

2. Specifications

 

   2.1 Input DC Power Port  

      

Input Voltage

36Vdc ~ 72Vdc, Normal: 48Vdc

Input Current

0.95A@48Vin at full load

 

 

        2.2 Output Port Voltage and Current

Output

56Vdc

Max. Load

0.625A

Power

35W max. (IEEE802.3at complaint)

Min. Load

0.01A

Load reg. (%)

5%

Line reg. (%)

1%

Ripple (%)

1%

Noise (%)

1%

 

 

3. Efficiency :

 

Efficiency

78% min. at full load, 36Vdc ~ 72Vdc input voltage

 

 

4. Protection

 

 

Short Circuit protection

Output short GND Terminal will not damage the Power Supply and will Auto-Reset

In Fuse Protection

Yes

Over Current

120~ 160% at 48Vdc Input F.L

Input Polarity Reverse Protection

No Output

Input Over Voltage Protection

72.3V ~ 72.8V Turn-Off Input

Input Over Low Voltage Protection

33.1V ~ 33,8V Turn-Off Input

Safety Standard

UL1950, CSA22.2 & TUV EN60950-1

EMC

FCC Class B, EN55022 Class B

Surge Protection on Data Input Ports

    Output Voltage

Data 5V

    Clamping Voltage

Data 16.5V (@I PP =5A, t p =8/20μs, I/O pin to GND)

    Peak Pulse Current

20A (tp=8/20μs)

    Pin Protected

All 8 pin protected

    Max. Shut Capacitance

<3pF (VR = 0V, f = 1MHz, I/O pin to GND)

< 1.5 pF (VR = 0V, f = 1MHz, Between I/O pins)

IEC Compatibility

IEC61000-4-2 (ESD) ±15kV (air), ±8kV (contact)

IEC61000-4-4 (EFT) 40A (5/50ns)

IEC61000-4-5 (Lightning) 20A (8/20μs)

 

 

 

 

 

 

5. General info

 

Operation Temp.

-40 ~ 70

Storage Temp.

-40 ~ 85

Operation Humidity

5% ~ 90%

Cooling

Free Air Cooling

Size

46 x 125 x 102 mm (W * H * D)

 

 

 

6. RJ45 pinouts assignment: (10M/100M/1000M)

   6.1 : DIN-POE-3AD

 

 

RJ-45 Input (Data Only)

RJ-45 Output (Data & Power)

Pin

Symbol

Description

Symbol

Description

1

BI_DA+

Data Pair A+

-Vdc+BI_DA+

Power (-)+Data Pair A+

2

BI_DA-

Data Pair A-

-Vdc+BI_DA-

Power (-)+Data Pair A-

3

BI_DB+

Data Pair B+

+Vdc+BI_DB+

Power (+)+Data Pair B+

4

BI_DC+

Data Pair C+

BI_DC+

Data Pair C+

5

BI_DC-

Data Pair C-

BI_DC-

Data Pair C-

6

BI_DB-

Data Pair B-

+Vdc+BI_DB-

Power (+)+Data Pair B-

7

BI_DD+

Data Pair D+

BI_DD+

Data Pair D+

8

BI_DD-

Data Pair D-

BI_DD-

Data Pair D-

 

 

   6.2 : DIN-POE-3ARD

 

 

RJ-45 Input (Data Only)

RJ-45 Output (Data & Power)

Pin

Symbol

Description

Symbol

Description

1

BI_DA+

Data Pair A+

+Vdc+BI_DA+

Power (+)+Data Pair A+

2

BI_DA-

Data Pair A-

+Vdc+BI_DA-

Power (+)+Data Pair A-

3

BI_DB+

Data Pair B+

-Vdc+BI_DB+

Power (-)+Data Pair B+

4

BI_DC+

Data Pair C+

BI_DC+

Data Pair C+

5

BI_DC-

Data Pair C-

BI_DC-

Data Pair C-

6

BI_DB-

Data Pair B-

-Vdc+BI_DB-

Power (-)+Data Pair B-

7

BI_DD+

Data Pair D+

BI_DD+

Data Pair D+

8

BI_DD-

Data Pair D-

BI_DD-

Data Pair D-

 

 

   6.3 : DIN-POE-3BD

 

 

RJ-45 Input (Data Only)

RJ-45 Output (Data & Power)

Pin

Symbol

Description

Symbol

Description

1

BI_DA+

Data Pair A+

BI_DA+

Data Pair A+

2

BI_DA-

Data Pair A-

BI_DA-

Data Pair A-

3

BI_DB+

Data Pair B+

BI_DB+

Data Pair B+

4

BI_DC+

Data Pair C+

+Vdc+BI_DC+

Power (+)+Data Pair C+

5

BI_DC-

Data Pair C-

+Vdc+BI_DC-

Power (+)+Data Pair C-

6

BI_DB-

Data Pair B-

BI_DB-

Data Pair B-

7

BI_DD+

Data Pair D+

-Vdc+BI_DD+

Power (-)+Data Pair D+

8

BI_DD-

Data Pair D-

-Vdc+BI_DD-

Power (-)+Data Pair D-

 

 

Note : the model is isolated design, the output +/- or input +/- can be shorted to ground 

            (FG).

 

 

 

 

 

Contact Supplier

Mr. Allan Lee Marketing/ Sale Dire Chat Now
Telephone
886-2-66215899
Mobile
886935875828
Fax
886-2-66210998
Address
4/F-2, No. 130

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Telecommunications > Communication Equipment > Other Telecommunications Products
Categories
Hi~