AC Vlf High Voltage Tester 90kv
USD $360 - $8,388 /Unit
Min.Order:1 Unit
Huazheng Electric Manufacturing (Baoding) Co., Ltd.
AC Vlf High Voltage Tester 90kv
MOQ: 1 PC ! The suplier of State Grid ! Standard: CE ISO!
AC Vlf High Voltage Tester 90kv selection:
1.0.1Hz -30KV Ultra-Low Frequency High Voltage Generator
Model | Rated Voltages | Load capacity | Fuse | Weight | Useful |
VLF- 30/1.1 | 30KV (peak ) | 0.1Hz,≤1.1µF | 10A | Control :6Kg Body Boost :30Kg | 10KVCables, Generator |
0.05Hz,≤2.2µF | |||||
0.02Hz,≤5.5µF |
2.How to choose the suitable products for test
Please make sure that the capacitance of test products is below the
instrument rated capacitance. The waveform will be influence if the
capacitance of test products is too small and the instrument can not
normally output when it below 0.05µF. 0.1µF capacitor in parallel to
auxiliary output. Below is capacitance of some instrument for your
reference
Single relatively power capacity of different Generator Table 2
| Thermal Power | Hydropower | |||||
Generator capacitance (MW) | 200 | 300 | 600 | 85 | 125-150 | 300 | 400 |
Single relatively power capacity(µF) | 0.2-0.25 | 0.18-0.26 | 0.31-0.34 | 0.69 | 1.8-1.9 | 1.7-2.5 | 2.0-2.5 |
Power capacitance of single-core XLPE insulated cable (µF/km)
Table 3
| Capacity µF/Km | |||||||||||
Voltage (kV) | 10 | 0.15 | 0.17 | 0.18 | 0.19 | 0.21 | 0.24 | 0.26 | 0.28 | 0.32 | 0.38 | - |
35 | - | - | - | 0.11 | 0.12 | 0.13 | 0.14 | 0.15 | 0.16 | 0.17 | 0.19 | |
Cross-sectional area (cm²) | 16 | 25 | 35 | 50 | 70 | 95 | 120 | 150 | 185 | 240 | 270 |
AC Vlf High Voltage Tester 90kv parameters:
1 ,output rated voltage , Table 1 for reference
2 ,output frequency :0.1Hz ,0.05Hz ,0.02Hz .
3 ,loading capability : Table 1 for reference
0.1 Hz maximum 1.1µF
0.05 Hz maximum 2.2µF
0.02 Hz maximum 5.5µF
4 ,accuracy :± (3% of full scale +0.5 KV)
5 ,voltage waveform distortion :≤5%
6 ,condition of use : indoor, outdoor; temperature : -10 ℃~+40 ℃ ;humidity :≤85%RH
7 ,power supply :AC50 Hz ,220V ±5%
8 ,power fuse : Table 1 for reference
From the date of purchase within one year instrument, is a product quality problem free repair replacement, lifetime supply of maintenance and technical services. The instrument has found anomalies or malfunctions please contact us to arrange the most convenient treatment options.