Testing equipment manufacturers 60kv 80kv Vlf AC Hipot Testing Machine
USD $360 - $8,388 /Unit
Min.Order:1 Unit
Huazheng Electric Manufacturing (Baoding) Co., Ltd.
1.vlf hipot insulation resistance tester Technical parameters:
Model | Peak voltage | Measuring range | Weight | Purpose |
VLF-30 | 30KV | 0.1Hz,≤1.1µF | Controller: 4 kg Booster: 25 kg Size: L*W*H 323*174*323 | 10KV and below voltage cable, generator |
0.05Hz,≤2.2µF | ||||
0.02Hz,≤5.5µF | ||||
VLF-40 | 40KV | 0.1Hz,≤1.1µF | Controller: 5 kg Booster: 30 kg Size: L*W*H 357*208*343 | 13.8KV and below voltage cable, generator |
0.05Hz,≤2.2µF | ||||
0.02Hz,≤5.5µF | ||||
VLF-50 | 50KV | 0.1Hz,≤1.1µF | Controller: 6 kg Booster: 45 kg Size: L*W*H 357*210*365 | 15.75KV and below voltage cable, generator |
0.05Hz,≤2.2µF | ||||
0.02Hz,≤5.5µF | ||||
VLF-60 |
60KV
| 0.1Hz,≤1.1µF | Controller: 6 kg Booster: 50 kg Size: L*W*H 357*220*370 | 18KV and below voltage cable, generator |
0.05Hz,≤2.2µF | ||||
0.02Hz,≤5.5µF | ||||
VLF- 80 |
80KV | 0.1Hz,≤1.1µF | Controller: 8 kg Booster: 90 kg Size: L*W*H 357*240*390 | 35KV and below voltage cable, generator |
2.vlf hipot insulation resistance tester feature
1. Data of current, voltage, wave form can be directly sampled at high voltage side, so the data is real and accurate.
2. Overvoltage protection: If the output exceeds the set limit of voltage, the instrument will shut-down to protect itself, the actuation time is less than 20ms.
3. Overcurrent protection: It is high-low voltage dual protection in the design, the accurate shut-down protection can be made according to the set value at high voltage side; If the current on low voltage side exceeds the rated current, the instrument will take shut-down protection, the actuation time are both less than 20ms.
4. A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protective resistor connected outside
3.How to choose the suitable products for test
Please make sure that the capacitance of test products is below the instrument rated capacitance. The waveform will be influence if the capacitance of test products is too small and the instrument can not normally output when it below 0.05µF. 0.1µF capacitor in parallel to auxiliary output. Below is capacitance of some instrument for your reference.
AC hipot tester
and the MEE Exhibition in Dubai on 1st to 3rd March 2016. And they are very successful. The follow is the photos that we attended the Power-gen Exhibition and the MEE Exhibition.
AC hipot tester
HuaZheng Electric Manufacturing (Baoding) Co.,Ltd is founded in 2008,the supplier of the State Grid in China.It means we are the supplier of the Chinese Government.And our products spread throughout the whole China.
Close to Tianjin port, the transportation is convenient. our customers come from different countries like America, England, Bulgaria, Brazil, Chile, Malysia, Vietnam and so on.
Our main products are Insulation Oil Tester, Cable Fault Locator, Power Quality Analyzer, High Voltage Generator, High Voltage Capacitor, Testing Transformer and so on.
What's more, gurantee 1 year,life long maintance .Products through the CE, ISO, IEC certification, quality and reliable, factory price.
AC hipot tester
AC hipot tester