Product name: 12kV ring main unit

Model no.: HXGN-12

Description:

HXGN-12 ring main unit is a cost effective extensible switchgear for three phase AC 50Hz, 12kV distribution system, and widely used in utility, industrial and commercial applications. 

Technical parameters:

Rated voltage 12kV
Rated power frequency withstand voltage (1min) 42kV
Rated lightning impulse withstand voltage 75kV
Rated frequency 50Hz, 60Hz
Rated current 630A (Load break switch)
125A (Load break switch-fuse combination)
Rated short-time withstand current (4s) 20kA
Rated peak withstand current 50kA
Rated voltage of auxiliary control circuit DC/AC 110V/220V
Protection degree IP2X 
Size (W*D*H) 800 / 900*1000*2000mm

Features:

1. Metal-clad and fully enclosed structure, can prevent dirt and small animals from entrance. 

2. Through the observation windows in the door panel, switch position and general condition can be clearly viewed.

3. The door and switch operating handle are mechanically interlocked to ensure the door cannot be opened with the switch closed and the switch cannot be closed with the door open. 

4. The switchgear use vacuum switches combined with solid insulation material. This environmentally-friendly technology avoid the uses of SF6 as an insulation gas.

5. Reliable FIVE-PREVENTION interlock can effectively prevent from mal-operation.

    1). Prevent switching on or off disconnector when circuit breaker, load break switch or contactor are in switching on condition.

    2). Prevent switching on or off circuit breaker, load break switch or contactor by mal-operation.

    3). Prevent switching on circuit breaker or load break switch when earthing switch is in switching on condition.

    4). Prevent switching on earthing switch in live condition.

    5). Prevent entering compartments in live condition.

Sturcture:

1. Enclosure is built around steel skeletal construction, and apply epoxy resin power spray coating, the above adopted treatment methods ensure a very strong anti-corrosion capacity for the switchgear housing.

2. The cubicle is separated into several functional compartments by metal sheet, including busbar compartment, circuit breaker compartment, cable compartment and low voltage compartment. Fused or non-fused load break switch is installed in circuit breaker compartment.

3. Pressure relief channels are included. In case of faults inside the compartments resulting in arc, the pressure is released from pressure relief channels. In this way, it can ensure the safety of operating staff and the cubicle.

12kV ring main unit

Climate and environment:

1. Altitude: ≤ 1000m

2. Temperature: -15℃ to 40℃

3. Relative humidity: 

    Daily average relative humidity: ≤ 95%

    Monthly average relative humidity: ≤ 90%

Standards applied:

No.Standard no.Title
1IEC 62271-200:2003Alternating-current metal-enclosed switchgear and controlgear for rated voltage above 1kV and up to and including 52kV
2IEC 62271-1:2007High-voltage switchgear and controlgear - Part 1: Common specifications
3IEC 60060-1:2010High-voltage test techniques - Part 1: General definitions and test requirements
4GB 3906-2006Alternating-current metal-enclosed switchgear and controlgear for rated voltage above 3.6kV and up to and including  40.5kV
5GB/T 11022-2011Common specifications for high-voltage switchgear and controlgear standards
6DL/T 404-2007Alternating-current metal-enclosed switchgear and controlgear for rated voltage above 3.6kV and up to and including  40.5kV
7GB 50060-2008Code for design of high voltage electrical installation (3 ~ 110kV)
8GB/T 16927.1-2011High-voltage test techniques - Part 1: General definitions and test requirements

Selection of switchgear:

If customer has special requirement, please contact and consult with us.

Typical primary scheme diagram:

12kV ring main unit

About Us

12kV ring main unit12kV ring main unit 

Exported Project

12kV ring main unit12kV ring main unit 

Packaging & Shipping

12kV ring main unit 

Certificate

12kV ring main unit 

Contact us

12kV ring main unit 

Contact Supplier

Mr. Shane Deng Sales Manager Chat Now
Telephone
86-710-3253168
Fax
86-710-3253158
Address
Building B38, Jiahai Industrial Park, High-Tech Zone Hubei

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Power Distribution Equipment
Categories
Hi~