ES-S03 MINI AC/ DC 9v smoke alarms

ES-S03 MINI AC/ DC 9v smoke alarms

USD $1 - $4 /Piece

Min.Order:1000 Pieces

Supply Ability:
150000 Piece / Pieces per Month
Port:
NINGBO

Quick Details View All >

Place of Origin:
Zhejiang, China
Brand Name:
energylux
Model Number:
ES-S03
Usage:
Temperature Sensor
Theory:
Inductance Sensor
Output:
Switching Transducer

Ningbo Energylux Optoelectronics Technology Co., Ltd.

Business Type: Manufacturer,Trading Company
Ningbo Zhejiang China
Main Products: Sensor fit for lamps ,Wall hidden sensors ,Ceiling mount sensors ,Infrared sensor lamp ,Sensor lawn lamp

Product Details

 

Product Description

Certification:CE/ROHS

 

Welcome to read ES-S03wireless electric smoke alarm 

 

They are photoelectric smoke alarms, they are generally more effective at detecting smoldering fires which smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. 

 

IMPORTANT! PLEASE READ CAREFULLY AND KEEP IT. This user’s manual contains important information about your smoke alarm’s operation. To insure your safety, you need install one alarm at least in your every single room. Please don’t open the smoke alarm for that may cause improper effect. If you are installing this smoke alarm for use by others, you must leave this manual –or a copy of it—with the end user.

 

Model:ES-S03         


                                                        

ES-S03 MINI AC/ DC 9v smoke alarms   

Power Source:DC 9V 110V-220V/AC  
Power Frequency:50/60HZ
Static Current                     

<10uA

Alarm Current: <12mA
Low Voltage ALarm:5.5V-6.2V
Current:

<25mA

Alarm Volum:>85db(3m)
Working temperature:<-10℃~+40℃
Working Humidity:<93%RH
Low Battery Alarm:6.2-6.8v

 

 

 

WHERE TO INSTALL SMOKE ALARMS

  1.  At first, you need install them in your bedroom and routeway, and should install one item in every bedroom at least.
  2. Stairway is important for you to rush out when fires occur, so there must install smoke detectors.
  3. You at least require one smoke alarm on every floor,including finished attics and basements.
  4. Install one alarm beside every electric facility.
  5. Install smoke alarms in the middle of ceiling,because smog,heat and flashes always lift to the top of rooms
  6. If some reasons cause you can’t install them in the middle of ceiling,you need to install them at least 10cm away from the wall.
  7. If you like to install them on the wall, they should be installed 10-30.5cm away under the ceiling. 
  8. You need install more than one alarm when the length of your hall exceeds 9m.
  9.  In an ablique roof room,install the alarm 0.9m away from the top.
  10. How to install smoke alarms in a removable house.The removable house is short of heat isolation,so you’d better install the alarm 10-30.5cm away from the ceiling.for safety you need install another one near your bedroom,too;

WHERE NOT TO INSTALL SMOKE ALARMS 

  1. Where combustion particles are produced. Combustion particles form when something burns. Avoid installing in the areas include poorly ventilated kitchens,garages,and furnace rooms.Keep units at least 6m from the sources of combustion particles(stove,furnace,water heater,space heater)if possible.Ventilate these areas as much as possible.
  2. In air streams near kitchens.Air currents can draw cooking smoke into the sensing chamber of a smoke alarm near the kitchen.
  3. In very damp,humid or steamy areas,or directly near bathrooms whith showers.Keep units at least 3m away from showers saunas,dishwhashers,etc.
  4. Where the temperatures are regularly below 40 F(4 C)or above 100F(38 C),including unheated buildings,outdoor rooms,porches,or unfinished attics or basements.
  5. In very dusty,dirty,or greasy areas.Don’t install a smoke alarm directly over the stove or range.Clean a laundry room unit frequently to keep it free of dust or lint.
  6. Near fresh air vents,ceiling fans,or in very drafty areas.Drafts can blow smoke away from the unit,preventing it from reaching the sensing chamber.
  7. In insect infested areas.Insects can clog openings to the sensing chamber and cause unwanted alarms.
  8. Less than 305mm away from fluorescent lights.Electrical “noise” can interfere with the sensor.
  9. In “dead air”space, near the corner less than 10cm.
  10. If you have a smoking meeting room, don’t install the alarm there for the unit will alarm when several persons smoke;
 

 

Company Information

 ES-S03 MINI AC/ DC 9v smoke alarms

OFFICEES-S03 MINI AC/ DC 9v smoke alarms

 SAMPLE ROOM

 

ES-S03 MINI AC/ DC 9v smoke alarms

 

 

 

 

 

 

 

 

ES-S03 MINI AC/ DC 9v smoke alarms

  

 

Contact Supplier

Mr. Allan W Manager Chat Now
Telephone
0086-574-65131599
Address
Qiaotouhu Ningbo,Zhejiang

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electronic Components & Supplies > Active Components > Sensors
Categories
Hi~