inline electro magnetic flow meter
USD $299 - $4,999 /Set
Min.Order:1 Set
Kaifeng Qingtianweiye Flow Instrument Co., Ltd.
inline magnetic flow meter
Technical Parameters for electromagnetic flowmeter | |||
Caliber | DN3~DN3000mm | ||
Nominal Pressure | 0.6~4.0MPa(special pressure can be made too) | ||
Accuracy | ±0.5%,±0.3% or ±0.2% are selectable | ||
Liner material | Teflon,PFA,F46,Neoprene,Polyurethane | ||
Electrode Type | General type ,scraper type and replaceable type | ||
Electrode material | Stainless steel SUS316,Hastelloy C,Titanium,Tantalum Platinum-iridium,Stainless steel covered with tungsten carbide | ||
Medium Temperature | Integral type | -20°C~+60°C | |
Remote type | Neoprene & Polyurethane Liner | -10°C~+80°C | |
PTFE Liner /PFA Liner /F46 Liner | -10°C~+160°C | ||
Ambient Temperature | -25°C ~+ 60°C | ||
Ambient Humidity | 5~100%RH(relative humidity) | ||
Medium Electrical conductivity | ≥20μ s/cm | ||
Measuring Range | 1500:1,flow rate<15m/s | ||
Structure type | Integral type,remote type,submersible type,ex-proof type | ||
Protection Class | IP65,IP68(optional) | ||
Ex-proof Mark | ExmdⅡT4 | ||
Product Standard | JB/T 9248-1999 Electormagnetic Flowmeter |
Main performances of the electromagnetic flowmeter lining materials | ||
Lining material | Main Performance | Applications |
Teflon | 1.The most steady material in plastics which is resistibal to boiling hydrochloric acid,vitriolandqua fortis as well as strong alkali and organic impregnates. 2.Not be perfect in abrasion resistance. | Strong corrosive mediums such as strong acid and alkali |
PFA | Having the same abrasion resistance with PTFE.Having strong ability of load pressure resistance. | Applicable in state of load pressure |
F46 | 1.Have the same abrasion resistance with PTFE.2.Resistable for low abrasion.3.Having strong resistance to load pressure. | 1.The same as PTFE.2.Applicable in mediums of low abrasion. |
Neoprene | 1.Be of good elasticity,retractility and abrasion resistance.2.Be resistant to low aicd,alkali and salt but not for oxidation mediums. | Water,sewage and slurry,mineral serosity of low abrasion. |
Polyurethane | 1.Be of good abrasion resistibility. 2.Not be perfect in acid/alkali resisitance.3.Can't be used for water mixed with organic impregnants. | Applicable in mineral serosity,slurry and coal slurry of high abrasion. |
Main performances of the electromagnetic flowmeter electrode materials | |
Electrode material | Applications |
SUS316 | Applicable in water,sewage and corrosive mediums.Widely used in industries of petrol,chemistry,carbamide,etc |
Stainless steel covered with tungsten carbide | Applicable in mediums of no corrosive and low abrasion. |
Hastelloy B(HB) | Having strong resistance to hydrochloric acid of any consistance which is below bioling piont.Also resistable against vitriol,phosphate,hydrofluoricacid,organic acid etc which are oxidable acid,alkali and non-oxidable salt. |
Hastelloy C(HC) | Be resistant to oxidable acid such as nitric acid,mixed acid as well as oxidable salt such as Fe+++,Cu++and sea water |
Titanium | Applicable in seawater,and kinds of chloride,hypochlorite salt,oxidable acid(including fuming nitric acid),organic acid,alkali etc.Not resistant to a pure reducing acid(such as sulphuric acid,hydrochloric acid)corrosion.But if acid contains antioxidant(such as Fe+++,Cu++)is greatly reduce corrosion. |
Tantalum | Having strong resistance to corrosive mediums that is similar with glass.Almost applicable in all chemical mediums.Except for hydrofluoric acid,oleum and alkali. |
Platinum-iridium | Almost be applicable in all chemical mediums except for aqua fortis,ammonium salt. |
Flow quantity and Flow rate Comparison Table