CE proved waste water Electromagnetic Flow meter measurement
USD $300 - $5,000 /Set
Min.Order:1 Set
Kaifeng Qingtianweiye Flow Instrument Co., Ltd.
CE proved waste water Electromagnetic Flow meter measurement
Intelligent electromagnetic flow meter is hallmarked by its high performance and reliability based on successful, field-proven technology. It is being widely used in industries such as petroleum, chemical engineering, iron and steel, food, electricpower, paper making, water treatment, petrochemical, medicine etc.
Model | DN6~DN3000mm | ||
---|---|---|---|
Nominal Pressure | 0.6~1.6MPa(2.5Mpa/4.0Mpa/6.4Mpa...42Mpa) | ||
Accuracy | ±0.5%,±0.3%or±0.2% are selectable | ||
Liner material | Teflon,PFA,F46,Neoprene,Polyurethane | ||
Electrode Type | General type ,scraper type and replaceable type | ||
Electrode material | Stainless steel SUS316,Hastelloy C,Titanium,Tantalum Platinumiridium, Stainless steel covered with tungsten carbide | ||
Mediem temperature | Integrate type | -20°C~+60°C | |
Remote type | Neoprene & Polyurethane Liner | -10°C~+80°C | |
PTFE Liner /PFA Liner /F46 Liner | -10°C~+160°C | ||
Ambient Temperature | -25°C ~+ 60°C | ||
Ambient Humidity | 5~100%RH(relative humidity) | ||
Medium Electrical conductivity | >=5u s/cm | ||
Measuring Range | 1500:1,flow rate<15m/s | ||
Structure type | Integral type,remote type,submersible type,ex-proof type | ||
Protection Class | IP65,IP68(optional) | ||
Ex-proof Mark | ExmdⅡT6 | ||
Product Standard | JB/T 9248-1999 Electormagnetic Flowmeter |
Electrode material | Applications |
---|---|
sainless steel SUS316 | Applicable in water,sewage and corrosive mediums. |
Widely used in industries of petrol,chemistry,carbamide,etc | |
Stainless steel covered with tungsten carbide | Applicable in mediums of no corrosive and low abrasion. |
Hastelloy B(HB) | Having strong resistance to hydrochloric acid of any consistance which is below bioling piont. |
Also resistable against vitriol,phosphate, | |
hydrofluoricacid,organic acid etc which are oxidable acid,alkali and non-oxidable salt. | |
Hastelloy C(HC) | Be resistant to oxidable acid such as nitric acid,mixed acid |
as well as oxidable salt such as Fe+++,Cu++aStnd sea water | |
Titanium | Applicable in seawater,and kinds of chloride,hypochlorite salt,oxidable |
Not resistant to a pure reducing acid(such as sulphuric acid,hydrochloric | |
But if acid contains antioxidant is greatly reduce corrosion. | |
Tantalum | Having strong resistance to corrosive mediums that is similar with glass |
Almost is applicable to all chemical mediums. | |
Except for hydrofluoric acid,oleum and alkali. | |
Platinum-iridium | Almost be applicable in all chemical mediums except for ammonium salt. |
Pipe Size | Min.Flow Rate (0~0.5m/s) | Min.Flow Rate (0~10m/s) | |
---|---|---|---|
mm | inch | L/min,m3/h | L/min,m3/h |
10 | 3/8 | 0 ~ 2 L/min | 0 ~ 40 L/min |
15 | 1/2 | 0 ~ 5 L/min | 0 ~ 100 L/min |
20 | 3/4 | 0 ~ 7.5 L/min | 0 ~ 150 L/min |
25 | 1 | 0 ~ 10 L/min | 0 ~ 200 L/min |
32 | 1.25 | 0 ~ 20 L/min | 0 ~ 400 L/min |
40 | 1.5 | 0 ~ 30 L/min | 0 ~ 600 L/min |
50 | 2 | 0 ~ 3 m3/h | 0 ~ 60 m3/h |
65 | 2.5 | 0 ~ 6 m3/h | 0 ~ 120 m3/h |
80 | 3 | 0 ~ 9 m3/h | 0 ~ 180 m3/h |
100 | 4 | 0 ~ 12 m3/h | 0 ~ 240 m3/h |
125 | 5 | 0 ~ 21 m3/h | 0 ~ 420 m3/h |
150 | 6 | 0 ~ 30 m3/h | 0 ~ 600 m3/h |
200 | 8 | 0 ~ 54 m3/h | 0 ~ 1080 m3/h |
250 | 10 | 0 ~ 90 m3/h | 0 ~ 1800 m3/h |
300 | 12 | 0 ~ 120 m3/h | 0 ~ 2400 m3/h |
350 | 14 | 0 ~ 165 m3/h | 0 ~ 3300 m3/h |
400 | 16 | 0 ~ 225 m3/h | 0 ~ 4500 m3/h |
450 | 18 | 0 ~ 300 m3/h | 0 ~ 6000 m3/h |
500 | 20 | 0 ~ 330 m3/h | 0 ~ 6600 m3/h |
600 | 24 | 0 ~ 480 m3/h | 0 ~ 9600 m3/h |
700 | 28 | 0 ~ 660 m3/h | 0 ~ 13200 m3/h |
800 | 32 | 0 ~ 900 m3/h | 0 ~ 18000 m3/h |
900 | 36 | 0 ~ 1200 m3/h | 0 ~ 24000 m3/h |