China manufacturer Nylon 6 pleated filter catridge
Negotiable
Min.Order:1
Zhangjiagang Deyizhou Precision Filter Material Co., Ltd.
China manufacturer Nylon 6 pleated filter catridge
Filter membrane, developed by Deyizhou Company, is adopted in the product as filter media. The product is produced by overall sweat soldering. It has excellent filtration performance and high economic feature, which has been applied in the market for more than 20 years.
1.The filter membrane is hydrophilic with absolute filtration accuracy
2.Wide chemical compatibility
3.Extremely low precipitates
4.Even aperture distribution and excellent filtration effect
1.Sterile filtration of raw material medicine,injection,infusion and other drugs
2.Filtration of food, beverage and wine
3.Filtration of fine chemicals and pharmaceutical intermediates
Filter element material composition:
filter memebrane | nylon 6 filter membrane |
diversion material | polypropylene(PP) |
outer shell | polypropylene(PP) |
seal ring | please see filter element modle selection table |
Intergrity test:
aperture(um) | 0.1 | 0.2 | 0.3 | 0.45 | 0.65 |
the lowest bubbling point in pure water(MPa) | ≥0.48 | ≥0.28 | ≥0.25 | ≥0.16 | ≥0.13 |
Water flow capacity-pressure difference curve(10'' filter element)
Main application technical indicators:
maximum operating temperature | 60°c/0.1MPa |
maximum operating pressure difference | 0.42MPa/25°c |
recommended operating pressure difference | 0.1~0.2MPa/25°c |
maximum back-pressure difference | 0.2MPa/25°c |
effective filtration are(10 inches) | ≥0.6m² |
forward online steam sterilization(135°c) | 30min/time |
disinfection by disinfection cabinet(121°c) | 30min/time |
Quality assurance:
1.ISO9001: 2008 guaranteed quality management system
2.Traceability management system of each filter
3.Filter elements are flushed and pass integrity test before filter elements are left from the factory
4.The batch passes through bacterial challenge test for confirming 100% bacteria interception ability
Biological safety:
1.Biological Safety: The product materials comply with USP in-vivo VI-121 ℃ plastic biological response test
2.Endotoxin: <0.25EU/ml
3.Cleanliness: The product is in line with 2010 GMP requirements on injection of particles
4.Readily oxidizable substance: the substance should be in line with 2010 GMP test requirements of particle contents in injections after water rinsing for 2000ml
5.TOC/conductivity: after the product is flushed with 20L injection water at 25 ℃ (10"). It is in line with requirements of 2010 GMP on total organic carbon contents and conductivity in injection water.