ML1000 magnetostrictive level gauge
Negotiable /Set
Min.Order:1 Set
Yantai AUTO Instrument Precision Casting Co., Ltd.
The product is designed and certificated according to the explosion-proof requirement
which applies to the accurately measurement of processing container and storage container.
Instrument survey
alloy stainless steel
transport damage or not.
Installation step:
1. Take off the flange from the testing hole of the oil container.
2.please insert the detector to the installation hole of the flange.
3. Please install the liquid floater, interface floater, and locking to the detector step by step;
4.please insert the detector to the measuring hole.
5.please take up the detector after putting the end of the container, for the distance is 2-10mm from the detector to the container end for protecting the bar to bending.
6. Then tightening the detector locknut and flange.
Installation diagram
(1) measuring blind area
(2) Installation height
(3) Measuring range
(4) Actual liquid level
the instrument for the intrinsic type.
The power supply cable could use popular two-core cable,the outer diameter of
the cable is 5...9mm for guaranteeing the seal of the cable entrance. If the
electromagnetic interference exists, we suggest to use the shielding cable. Two
terminal of the shielding cable should be earthing. The shielding must directly
connect inner earthing terminal. The outer terminal of the shell must be earthing. If
having the earthing circuit, the shielding terminal of the instrument must be earthing
through a ceramic capacity(such as 1µ F 1500V) to restrain the low-frequency
earthing circuit, and the prevent high-frequency interference signal at the same
time.
PF PTFE soften cable detector, only for AT500-F
Installation mode:
LW top installation
MW side by side installation
TW end installation
Shell
A casting aluminum
S stainless steel
Process temperature
H1 -40-120°C
H1 -40-200°C
H2 -40-350°C
Output signal
M1 one liquid level HART Protocol
M2 interface level, one liquid level HART Protocol
M4 interface level, two liquid levels HART Protocol
/ Installation height(mm)
/measuring range(mm)
/medium density(g/cm)
/working pressure(MPa)