Non Surgical Facial Toning and Anti-wrinkle Beauty Machine Quality Choice
USD $3,100 - $3,900 /Set
Min.Order:1 Set
Race Medical & Beauty Equipment Co., Ltd.
Non Surgical Facial Toning and Anti-wrinkle Beauty Machine
(The results of over 18 years research, the most effective anti-aging treatment)
About Amb-mini
The result of over 18 years research, the award winning Amb-mini's Facial Toning treatment has been volted the most effective anti-ageing treatment available.
The Amb-mini is a multifunctional system combining RaceMBE Non Surgical Facial Toning with Body Sculpting. The system ability to target face and body treatment areas at the same time enable you to increase your revenue without the need to increase treatment time. The RaceMBE Amb-mini redefines facial muscles, reduces lines and wrinkles and tones sagging body muscles.
Amb-mini’s Applications
· Lifts and tones facial muscles
· Reduces the appearance of lines and wrinkles
· Increases blood and lymph circulation
· Enhances the penetration of skin care formulations
· Increases the production of collagen and elastin
· Increases protein synthesis and cell membrane transport
· Increases mitochondria activity and adenosine tiphosphate (ATP) production
Turbo ST Face & Body Skin Toning
Originally developed for treating facial palsy, micro current therapy is now widely used as an aesthetic anti-ageing treatment. True micro current that been called turbo ST uses a current with an intensity of less than one millionth of an amp (<1mA). A higher intensity current will cause contractions of the facial muscles which can worsen lines and wrinkles, whereas micro current stimulation does not contract muscles, but instead works by a process called muscle re-education to achieve results.
Due to it's dramatic lifting and toning effect, The Turbo ST micro current treatment has become known as the "Non Surgical Face Lift".
Turbo ST Increasing Elasticity Therapy
Turbo ST Increasing Elasticity Therapy combines active micro current rollers with Hydro Mask, a unique, electrically conductive silica gel mask that has been infused with powerful hydrating properties.
The rollers gently massage the face causing the mask to become electrically charged so that the whole face is bathed with rejuvenating energy.
The current delivered by the rollers recharges and replenishes the bio-electrical energy within the facial muscles, restoring tone and firmness.
Myo-E Photo Therapy
The Amb-mini offers Myo-E Photo Therapy, a novel application that combines both light and micro-current technologies in the same setting.
The micro-current works on a cellular level to help stimulate the healing process, to provide relief to the myofascial trigger points and to stimulate blood circulation and lymphatic flow.
Micro-current stimulation is produced in therapy at literally one millionth of an ampere which is believed to be the body's own natural current strength; this therefore, restores the body's own natural current.
Studies have shown that ATP production can increase five folds after micro-current therapy. It also increases protein synthesis and amino acid transport through the different layers of the skin.
Specifications
Descriptor | Characteristic Parameter |
Rated input voltage | AC220V±10%, 50/60Hz or AC110V±10%, 50/60Hz (optional) |
Rated input power | 30W |
Human interface | 8.0" touch TFT screen; IC card management; English/Chinese OS |
Turbo ST Micro current | · Waveform: Patent Simulative Bioelectric Wave · Frequency: 0.4-800Hz · Polarity: positive, negative & alternating · Range: 20-640uA · Mode: Automatic Sequential |
Myo-E Photo Therapy | · Light Wavelength: 625±5nm,465±5nm,520±5nm · Light Delivery: Direct from source · Type of light modulation: continuous and interval · Electric Parameter: Turbo ST Micro current · Myo-E Waveform: pulse bust · Frequency: 1-120Hz program internal setting · Pulse width: 100-500μs program internal setting · Polarity: positive-negative alternately · Amplitude: Max.40V ,adjustable by rotary switch |
Dimension | 33cm(D)×33cm(W)×19.5 cm(H) / 13”x13”x7.7” |
Net weight | 4.5Kg / 10Lbs |
Main Testing Standards:
IEC/EN 60601-1: Medical electrical equipment Part 1: General requirements for basic safety and essential performance
IEC/EN 60601-1-2: Medical electrical equipment Part 1-2: Electromagnetic compatibility - Requirements and tests
Race MBE regards product quality and service quality as strategic objectives. Our success and progress result from meeting the demands of customers, getting their trust and support.
Race MBE always tries to go ahead of customers' demands, which makes it has a bright prospect in market.
Race MBE is certified by ISO13485:2003(CN10/31187), and got Medical Device Manufacturing Permit from China Food and Drug Administration. All Race's products got CE certification, among which, those exported to American market got approval from FDA.
• RaceMBE builds a team by inviting outstanding engineering designers in the global scope. All products designed in California.
• Large-scale production in China, with materials procurement and production cost advantage.
• More than 20 years experience in aesthetics and medical equipment developing, manufacturing and marketing.
• RaceMBE is managed by grouping of enterprises, making purchase from different countries throughout the world.