HVAC air damper manufacturer in China/electric actuators/damper handle/damper forming machine/fire damper bending machine

HVAC air damper manufacturer in China/electric actuators/damper handle/damper forming machine/fire damper bending machine

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
250 Piece / Pieces per Month
Port:
Any Port in Guang Dong
Payment Terms:
T/T

Quick Details View All >

Place of Origin:
Guangdong, China
Brand Name:
COMIFO
Model Number:
CFH
Type:
HVAC Systems

Comifo Duct Manufacture Machine Co., Ltd.

Credit Member 4 years
Business Type: Manufacturer
Guangzhou Guangdong China
Main Products: Plasma Cutting Machine ,Comer Inserter ,Duct Manufacture Autoline V ,Duct Manufacture Autoline III ,TTF/LT Mate Flange Former

Product Details

Classification, Function, Structure & Feature of Fire/Smoke Damper

(Model: CFHF70)

C---- Company code

 

FH------ Classify code:

 

FH(fire type), PY(smoke type)

 

F------ Feature code:

 T: Air Volume

 C: Electromagnetism

 Q:  Automatic On or Off

 Y: Remote Manual Operation

 X:  Action Signal Output

 Z: Dead Weight Fire Damper

 B: Refold Smoke Damper

 K: Air Outlet (Or Exhauster Outlet)

 

70------- Main Parameter

 70: 70°C Temperature Sensor Off When it Reaches 70°C

280: 280°C Temperature Sensor Off When it Reaches 280°C

No Numeric Code:  No Temperature Sensor

 

Remark: In order to simplify the model number, all electromagnetism which with signal, no feature code was added; all smoke damper which with electromagnetism, the feature code “C” was omitted.

 

 

 

Model & Fuction Table

 

No.

Description

Model No.

Fuction

Shape

Normal Condition

1

Deadweight Fire Damper( Gravity Fire Damper)

CFHZ70(280)

70 °C(or 280 °C) Automatic Close

 

Circular/Rectangular

 

Open

2

 

Fire Damper

CFHF70(280)

70 °C(or 280 °C) Automatic Close, Manual Close, Manual Reset

 

Circular/Rectangular

3

 

Fire Regulative Damper

CFHT70(280)

70 °C(or 280 °C) Automatic Close, Manual Close, Manual Reset,Air Regulation

 

Circular/Rectangular

4

 

Fire (Smoke) Regulative Damper (with Signal)

CFHTX70(280)

70 °C(or 280 °C) Automatic Close, Manual Close, Manual ResetAir Regulation, Output signal and interlock Control

 

Circular/Rectangular

5

 

Smoke (Fire) Regulative Damper

CFHTC70(280)

Electric Signal Close, 70 °(or 280 °C) Automatic Close, Manual Close, Manual ResetAir Regulation, Output Signal and Interlock Control

 

Circular/Rectangular

6

 

Automatic Fire (Smoke) Regulative Damper

CFHTQ70(280)

Electric Signal Close, 70 °(or 280 °C) Automatic Close, Manual Close, Manual ResetAir Regulation, Output Signal and Interlock Control

 

Circular/Rectangular

7

 

Intelligent Automatic Fire Regulative Damper

CFHTQZ70(280)

Electric Signal Open, 70 °C(or 280 °C) Automatic Close, Manual Close, Manual ResetAir Regulation, Output Signal and Interlock Control

 

Circular/Rectangular

 

Close

8

 

Smoke Damper

CPY

Electric Signal Open, Manual Open, Manual Reset, Output Signal and Interlock Control

 

Circular/Rectangular

 

Close

9

 

Smoke (Fire) Damper

CPY280

Electric Signal Open, Manual Open,  280°C  Automatic Reclose , Manual Reset, Output Signal and Interlock Control

 

Circular/Rectangular

10

 

Remote Control Smoke Damper

CPYY

Electric Signal Open, Manual Open, Manual Reset, Output Signal and Interlock Control

 

Circular/Rectangular

11

 

Remote Control Smoke(Fire)Damper

CPYY280

Electric Signal Open, Manual Open,  280°C  Automatic Reclose , Manual Reset, Output Signal and Interlock Control

 

Circular/Rectangular

12

 

Fire ( Smoke) Air Outlet

CFHFK70(280)

Open,  Automatically close, automatically re-open under  280°C or 70 °C. 

 

Rectangular

 

Open

13

 

Panel Smoke Outlet

CPYB

Electric Signal Open, Manual Open, Manual Reset, Output Signal and Interlock Control, with decoration function

 

Rectangular

 

Close

14

Remote Control Horizontal Smoke/air Outlet

CPYYK-W

Electric Signal Open, Manual Open, Manual Reset, Output Signal and Interlock Control, use aluminiun alloy material to decorate, with decoration function

 

Rectangular

15

Remote Control Vertical Smoke/air Outlet

CPYYK-L

16

Horizontal Smoke/air Outlet

CPYK-W

Electric Signal Open, Manual Open, Manual Reset, Output Signal and Interlock Control, use aluminiun alloy material to decorate, with decoration function

 

Rectangular

17

Vertical Smoke/air Outlet

CPYK-L

18

Remote Control Horizontal Fire(Smoke)/air Outlet

CPYYK280-W

Electric Signal Open, Manual Open,  280°C  Automatic Reclose , Manual Reset, Output Signal and Interlock Control, use aluminiun alloy material to decorate, with decoration function. 

 

Rectangular

19

Remote Control Vertical Fire(Smoke)/air Outlet

CPYYK280-L

20

Horizontal Fire(Smoke)/air Outlet

CPYK280-W

Electric Signal Open, Manual Open, 280°C Automatic Reclose , Manual Reset, Output Signal and Interlock Control, use aluminiun alloy material to decorate, with decoration function.

 

Rectangular

21

Vertical Fire(Smoke)/air Outlet

CPYK280-L

 

 

 

Technical Parameter, Structure & Feature

 

Blade: 1.2~1.5mm

Blade Shaft: Φ10

Shaft Sleeve: Brass

Controller Classification:  emperature Sensor, Manual, Electric, Automatic

Manner of Execution:  Temperature Sensor, Manual, Electric

Voltage Rating(V):  DC24V±10%

Rated Current(A):  <0.5A

Micromove Switch:  Contact Rating 380V 0.3A

 

 

 

 

I.  Dead Weight Damper (Gravity Fire Damper) CFHZ70(280)

 

 

 

 

 

 

II.  Fire Damper CFHF70(280)

 


 

 

III. Fire Regulative Damper CFHT70 (280)

 

 

 

 

 

 

 

IV. Fire (Smoke) Regulative Damper (with Signal) CFHTX 70(280)

 

 

 

 

 

 

 V.  Smoke (Fire) Regulative Damper CFHTC70 (280)

 

 

 

 

 

 

 

VI.  Automatic Fire (Smoke) Regulative Damper CFHTQ70 (280)

 

 

 

 

 

Note:

1, When the air volume needs to be regulated, open to 90 degree, then adjust the regulative plate under the handle.

2, When the damper is electrically resetting, the motor should work untill it stops actomatically; Do no cut off the power supply when it is resetting.

 

 

VII.  Intelligent Automatic Fire Regulative Damper CFHTQZ70 (280)

 

 

 

VIII.  Smoke Damper CPY

 

 

Usually it keeps closing, smoke (temperature) sensor outputs electric signal (DC24V) through control center when fire happens, actuator powers on, damper opens automatically, and output open signal.

Manually open available.

Output electric open signal

Manually reset after damper works

 

 

 

IX.  Smoke(Fire) Damper CPY280

 

Usually it keeps closing, smoke (temperature) sensor outputs electric signal (DC24V) through control center when fire happens, actuator powers on, damper opens automatically, and output open signal. When smoke temperature reaches 280°C, damper recloses.

Manually open available.

Output electric open signal. Manually reset after damper works.

When smoke temperature reaches 280°C, damper recloses.

 

 

X.  Remote Control Smoke Damper CPYY

 

Usually it keeps closing, smoke (temperature) sensor outputs electric signal (DC24V) through control center when fire happens, the electromagnetism in the actuator powers on, damper opens automatically, and output open signal.

Remote manually open available.

Remote manually reset after damper works.

 

 

 

XI.  Remote Control Smoke(Fire)Damper CPYY280

 

Usually it keeps closing, smoke (temperature) sensor outputs electric signal (DC24V) through control center when fire happens, actuator powers on, damper opens automatically, and output open signal.

When smoke temperature reaches 280°C, damper recloses.

Remote manually open available.

Remote manually reset after damper works.

When smoke temperature reaches 280°C, fuse was melt, damper closes automatically.

 

 

 

XII.  Fire ( Smoke) Air Outlet CFHFK70(280)

 

Usage: Fire air outlet combines aluminum monolayer regulated shutter and thin fire damper. It is widely used on the exit of supply air duct or Intake of return air duct in HVAC system, which has fire protection requirements. Normally it is installed in the side of duct, terminal of duct or on the wall, also can be used as air outlet for regulating air flow direction.

 

 

Features:

 

 

XIII.  Remote Control Panel Smoke Outlet CPYKB

 

 

 

 

 

XIV.  Remote Control Horizontal (or Vertical) Smoke /Air Outlet CPYYK

 

 

 

 

XV.  Horizontal (or Vertical) Smoke Outlet/ Air outlet CPYK

 

 

 

 

 

As not only a product manufacturer, but also a machine manufacturer, Comifo makes all kinds of dampers and air duct products by using own-made machines. ( air damper,  volume control damper for duct,  damper handle,  damper quadrant,  volume damper,  motorized volume control damper,  noise damper,  electric air damper,  damper valve,  vcd damper,  duct damper,  motorized damper actuator,  motorized air damper,  air damper actuator,  motorized damper ventilation,  shut off damper,  air duct damper,  air conditioning damper)

 

With automatic fire damper frame auto lines (the detail can be found from  FIRE DAMPER FRAME LINK ), fire damper blade auto lines (the detail can be found from FIRE DAMPER BLADE LINK ), fire damper fastening table (the detail can be found from FIRE DAMPER FASTENING TABLE LINK ), we can make hundreds damper per day. It saves much more production time and labors. 

 

Moreover, beside using our own-made machines, the dampers are installed withour own band damper actuator, PREN. We research and develop damper actuator base on our more than 10 years damper manufacturing experience. The actuator is more cost-effective with high quality. If samples are required, please contact us. 

 

Comifo supplys fire damper and air duct products all over China, include of our many projects. We are the manufacturer, and the user. We can feedback any problems promptly when using our own machines, or products. It is a big advantages for us to improve our machines and products continueously. Most of problems may happen to customers, we can find and solve before put into the market. 

 

If customers who want to use automatic equipments to make dampers or ducts, we can help and supply machines and technical instruction. 

 

Customized machine according to customers' damper design are also available. 

 

Please contact us or visit our website to get more information. 

Contact Supplier

Ms. Helen Lin Manager Chat Now
Telephone
86-20-28879738
Fax
86-20-28879718
Address
3F,No.62,Jianzhong Road,Tianhe Software Park,Guangzhou,China Guangzhou,Guangdong

You May Like

New Products

Find Similar Products By Category

Construction & Real Estate > HVAC Systems & Parts
Categories
Hi~