- Metering of distribution feeders, transformers, generators, capacitor banks and motors
- Medium and low voltage systems
- Commercial, industrial, utility
- Power quality analysis
- Data Logging
FEATURES
Metering
- Voltage V1, V2, V3, Vlnavg, V12, V23, V31, Vllavg
- Current I1, I2, I3, In, Iavg
- Power P1, P2, P3, Psum
- Reactive Power Q1, Q2, Q3, Qsum
- Apparent Power S1, S2, S3, Ssum
- Frequency F
- Power Factor PF1, PF2, PF3, PF
- Energy Ep_imp, Ep_exp, Ep_total, Ep_net
- Reactive Energy Eq_imp, Eq_exp, Eq_total, Eq_net
- Apparent Energy Es
- Demand Dmd_P, Dmd_Q, Dmd_S, Dmd_I1, Dmd_I2, Dmd_I3
- Load Features
- Four Quadrant Powers
Monitoring
- Power Quality
- Voltage Harmonics 2nd to 63rd and THD
- Current Harmonics 2nd to 63rd and THD
- Voltage Crest Factor
- THFF (TIF)
- Current K Factor
- Voltage Unbalance Factor U_unbl
- Current Unbalance Factor I_unbl
- Max/Min Statistics with Time Stamps
Fexible I/O module
The E-moduleR technique was adopted for its flexibility and easy expansion of the I/O function of Acuvim II. A maximum of 3 modules can be used for one meter. Digital input, Digital output, pulse output, relay output, analog input and analog output are provided by I/O option module.
Communication
- RS485, Industry standard ModbusRprotocol
- Module Option: Ethernet module, Profbus-DP module
- Dual RS485 communication ports
- RS-485 (Standard): MODBUS RTU Protocol, 2-wire connection, Up to 38400 baud rate
- Ethernet (Optional): 10M/100M BaseT, MODBUSR TCP/IP Protocol, Data Browsing through HTTP, Sending e-mail automatically
- PROFI-BUS (Optional): PROFIBUS-DP/V0 Protocol; Work as PROFIBUS slave, baud rate adaptive, up to 12M; Typical input bytes: 32, typical output bytes: 32; PROFIBUS standard according to EN 50170 vol.2
Alarms
The limits of the less than 9 indicated parameters can be set with a specified, time interval. If any input of the 9 indicated parameters is over or under its setting limit with persisting time over specified time interval, the event will be recorded with time stamps and trigger the Alarm DO output. The 9 indicated parameters can be any of the following 34 ones. F, V1, V2, V3, Vlnavg, V12, V23, V31, Vllavg, I1, I2, I3, Iavg, In, P1, P2, P3, Psum, Q1, Q2, Q3, Qsum, S1, S2, S3, Ssum, PF1, PF2, PF3, PF, U_unbl, I_unbl, Dmd_P, Dmd_Q, Dmd_S
Data_logging
The Acuvim IIR, Acuvim IIE, model offers 4MB of onboard data logging memory to be used for historical trending. There are 3 assignable historical logs where the majority of the metering parameters can be recorded. A real time clock allows for any logged events to be accurately time stamped.
Display
Clear and large character LCD Screen display with white back light
Wide environmental temperature endurance
Display Load percentage, 4 quadrants power and load nature
Certificate